Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Int Orthop ; 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38652245

ABSTRACT

PURPOSE: Periprosthetic femoral fractures (PPFs) around the hip are challenging complications in orthopaedic surgery, particularly Vancouver type B2 (VTB2) fractures. The surgical management of these fractures is crucial and depends on various factors. Cementless short taper stem with plate osteosynthesis is an alternative surgical technique. This study aims to compare the outcomes of this surgical technique with revision arthroplasty (RA) with long stem in the treatment of VTB2 PPFs. METHODS: This retrospective study was conducted in a single medical institute from February 2010 to May 2019. Patients who had received either total hip arthroplasty or bipolar hemiarthroplasty and subsequently developed a VTB2 PPF were included; patients who sustained intra-operative fractures or received a cemented stem previously were excluded from the analysis. The patients were divided into two groups: group I received RA with cementless long stem, while group II underwent RA with cementless short taper stem with plate osteosynthesis. Demographic data, radiographic and functional outcomes, and complications were analyzed between the two groups. RESULTS: A total of 85 patients diagnosed with VTB2 PPFs were included in the study. There were no significant differences between the two groups in terms of demographic data, including age, gender, mean follow-up times, estimated blood loss, and operative times. The radiographic results showed that there was no significant difference in the incidence of subsidence and implant stability between the two groups. However, group II tended to have less subsidence and periprosthetic osteolysis. Patients in group II had significantly better functional scores (mean Harris hip score: post-operative: 60.2 in group I and 66.7 in group ii; last follow-up: 77.4 in group 1 and 83.2 in group II (both p < 0.05)). There were no significant differences in the overall complication rate, including infection, dislocation, re-fracture, and revision surgery, between the two groups. CONCLUSIONS: Both surgical techniques, cementless long stem and cementless short taper stem with plate osteosynthesis, are effective in the treatment of Vancouver B2 PPFs, with no significant differences in outcomes or complications. However, patients in cementless short taper stem with plate osteosynthesis had better functional scores at both post-operative and the last follow-up.

2.
J Chin Med Assoc ; 87(2): 179-188, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38095570

ABSTRACT

BACKGROUND: This study investigated the association between postoperative piriformis fossa and greater trochanter tubercle distance (distance from the deepest point of piriformis fossa to the most lateral greater trochanter tubercle [PG]) and cutout failure after cephalomedullary nail (CMN) osteosynthesis for intertrochanter fracture (ITF). A rotating femur model was designed to analyze PG variation during femur rotation. METHODS: From 2005 to 2010, 311 patients diagnosed of ITF (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association [AO/OTA] 31-A2 and A3) underwent CMN fixation at our institute were reviewed. Of these, 281 (90.3%) patients achieved union without complication, 21 (6.8%) had cutout failure, six (1.9%) had femoral head osteonecrosis, and three (1%) had nonunion during postoperative 2-year follow-up. The side difference of postoperative PG compared to contralateral uninjured hip (dPG) was analyzed between patients who had cutout failure and those who did not. In the rotating femur model, the PG was measured for every 2.5° increments of internal and external rotation from 0° to 50°. RESULTS: The dPG was significantly higher in the failure group (10.2 ± 4.2 vs 6.6 ± 3.5 mm, p <0.001). The odds ratio for lag screw cutout was 6.35 (95% CI, 1.10-11.6, p =0.003) for every 1 mm dPG increment. dPG exhibited high diagnostic performance in predicting cutout failure according to receiver operating characteristic curve analysis. The area under the curve was 0.774 (95% CI, 0.711-0.837). dPG yielded the greatest sensitivity (78.4%) and specificity (78.4%) to predict lag screw cutout when cutoff value being 8.65 mm. In rotating femur model, PG change from baseline demonstrated significant ( p <0.001) positive and negative correlation with increased external and internal rotation, respectively. CONCLUSION: Increased dPG is a risk factor of cutout failure for ITF osteosynthesis with CMN. In conjunction with tip-apex distance, fracture displacement, and reduction quality; dPG can help surgeons interpret postoperative radiograph and predict failure. However, it should be noticed that a proper and standard patient positioning is critical for accurate dPG measurement.


Subject(s)
Fracture Fixation, Intramedullary , Hip Fractures , Humans , Bone Nails/adverse effects , Hip Fractures/surgery , Bone Screws , Femur/surgery , Retrospective Studies , Treatment Outcome
3.
J Pediatr Orthop ; 43(6): e416-e420, 2023 Jul 01.
Article in English | MEDLINE | ID: mdl-37043437

ABSTRACT

BACKGROUND: The prevalence of developmental dysplasia of the hip (DDH) has been considered to be low in East Asia, but this may be incorrect because of inconsistent diagnostic definitions and testing criteria. In 2015, the AAOS released guidelines for systematic screening for DDH in newborns. We implemented these guidelines and compared DDH incidence and outcomes before and after their implementation. METHODS: We used a historic comparison cohort of newborns with DDH between July 2015 and May 2017 before guideline implementation (the preguideline group); their data were retrieved using electronic medical records. In this group, the newborns received general hip screening without systemic follow-up. The postguideline group included newborns who were screened for hip dysplasia and followed up per the AAOS guidelines between July 2017 and May 2019. Their data were prospectively collected. The primary outcome in the postguideline group was DDH incidence. Other outcomes included rates of referral, surgery, and complications, and DDH prognosis. RESULTS: The preguideline and postguideline groups included 3534 and 2663 newborns, respectively, of whom 49 (1.1%) and 225 (8.4%), respectively, were referred to the pediatric orthopaedic clinic enrolled. In the postguideline group, 35 patients were diagnosed as having DDH (incidence: 1.3%, 95% CI: 0.8%-1.9%). Both the incidence and referral rates were significantly higher in the postguideline group than in the preguideline group. Furthermore, the mean age at referral was 6.7±10.06 months and 0.9±0.25 months in the preguideline and postguideline groups, respectively, indicating a potential for early treatment in the postguideline group. Finally, the female sex was identified as a risk factor for residual hip dysplasia at 6 months of age. CONCLUSION: DDH incidence in East Asia seems comparable to that in Western countries. Implementing the AAOS guidelines increased the diagnosis rate and opportunity for early treatment initiation, thus potentially avoiding surgical intervention. Nevertheless, residual DDH may be detected in some patients at 6 months of age, particularly in female infants. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Developmental Dysplasia of the Hip , Hip Dislocation, Congenital , Hip Dislocation , Infant , Humans , Infant, Newborn , Child , Female , Taiwan , Hip Dislocation, Congenital/diagnosis , Hip Dislocation, Congenital/epidemiology , Hip Dislocation, Congenital/therapy , Risk Factors
4.
Eur Radiol ; 33(9): 6473-6481, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37012547

ABSTRACT

OBJECTIVES: This study investigated the progression of pubofemoral distance (PFD) with age and assessed the correlation between PFD and late acetabular index (AI) measurements. METHODS: This prospective observational study was conducted between January 2017 and December 2021. We enrolled 223 newborns who underwent the first, second, and third hip ultrasounds, and pelvis radiograph at a mean age of 18.6 days, 3.1 months, 5.2 months, and 6.8 months, respectively. The difference between PFD measured at serial ultrasounds and the correlation with AI were analyzed. RESULTS: The PFD increased significantly (p < 0.001) at serial measurements. The mean PFD at the first, second, and third ultrasounds were 3.3 (2.0-5.7), 4.3 (2.9-7.2), and 5.1 (3.3-8.0) mm, respectively. The PFD at three ultrasounds were all significantly (p < 0.001) and positively correlated with AI, with the Pearson correlation coefficients being 0.658, 0.696, and 0.753 for the first, second, and third ultrasounds, respectively. Using AI as reference, the diagnostic ability of PFD was calculated by the areas under the receiver operating characteristic curve, which was 0.845, 0.902, and 0.938 for the first, second, and third PFD, respectively. For the first, second, and third ultrasounds, PFD cutoff values of ≥ 3.9, ≥ 5.0, and ≥ 5.7 mm, respectively, yielded the greatest sensitivity and specificity in predicting late abnormal AI. CONCLUSION: The PFD naturally progresses with age and is positively correlated with AI. The PFD has potential for predicting residual dysplasia. However, the cutoff for abnormal PFD values may require adjustment according to the patient's age. KEY POINTS: • The pubofemoral distance measured in hip ultrasonography naturally increases as the infant's hips mature. • The early pubofemoral distance demonstrates a positive correlation with late acetabular index measurements. • The pubofemoral distance may help physicians predict abnormal acetabular index. However, the cutoff for abnormal pubofemoral distance values may require adjustment according to patient's age.


Subject(s)
Hip Dislocation, Congenital , Infant , Humans , Infant, Newborn , Adolescent , Hip Dislocation, Congenital/diagnostic imaging , Retrospective Studies , Acetabulum/diagnostic imaging , Radiography , Sensitivity and Specificity
5.
BMC Pediatr ; 22(1): 228, 2022 04 26.
Article in English | MEDLINE | ID: mdl-35473514

ABSTRACT

BACKGROUND: This study investigated the association between early Graf classification and femoral head coverage (FHC) with the acetabular index (AI) at the age of 6 months. METHODS: A prospective observational study was conducted between 2017-2018. Patients requiring Pavlik harness treatment and patients with syndromic dislocation or neurogenic dislocation were excluded. In total, 169 newborns with the first ultrasound performed at the mean age of 12.3 (0-15) days, the second ultrasound performed at the mean age of 3.2 (2.5-4.1) months, and the AI measured at the age of 6.6 (4.3-7.1) months were enrolled. The correlation between the AI and first and second alpha angles and FHC measurements, and the correlation of dysplasia in early ultrasound with dysplasia in the AI were analyzed. RESULTS: At the first ultrasound, only the FHC (P = .02) demonstrated a significant negative correlation with the AI. At the second ultrasound, both the alpha angle (P < .01) and FHC (P < .01) demonstrated a significant negative correlation with the AI. With the AI as a reference, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were found to be 77%, 7%, 5%, and 81%, respectively, for the first Graf; 91%, 37%, 9%, and 98%, respectively, for the first FHC measurement; 82%, 90%, 35%, and 99%, respectively, for the second Graf; and 95%, 97%, 68% and 99%, respectively, for the second FHC measurement. CONCLUSIONS: FHC and alpha angle exhibited significant negative correlations with the AI at six months, both ultrasound parameters may have the potential to predict AI in DDH screening. Compared to the ultrasound measurements taken at 2 weeks, Graf and FHC at 3 months demonstrated superior sensitivity, specificity, PPV, and NPV to detect abnormal AI. The best timing to perform ultrasound examination may need further research.


Subject(s)
Hip Dislocation, Congenital , Child , Child, Preschool , Hip Dislocation, Congenital/diagnostic imaging , Hip Dislocation, Congenital/therapy , Humans , Infant , Infant, Newborn , Predictive Value of Tests , Prospective Studies , Ultrasonography
6.
J Child Orthop ; 15(5): 451-457, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34858531

ABSTRACT

PURPOSE: The purpose of this study was to investigate pulmonary function and health-related quality of life after traditional growing rod (TGR) procedures. METHODS: Between January 2006 and December 2017, a retrospective observational study of 17 early onset scoliosis (EOS) patients with a mean follow-up of 6.2 years (2.3 to 10.4) was conducted. The forced expiratory volume in one second (FEV1), expiratory forced vital capacity (FVC) and 24-Item Early Onset Scoliosis Questionnaire (EOSQ-24) score before the index surgery and at last follow-up were investigated. RESULTS: The mean percentage of predicted FEV1 improved from 50% (20% to 86%) to 53% (15% to 80%; p = 0.08); and the mean percentage of predicted FVC improved from 51% (24% to 81%) to 55% (25% to 89%; p = 0.06). The mean EOSQ-24 score was 78.2 (58 to 90) preoperatively and 77.2 (55 to 88) at last follow-up, there was no statistical difference (p = 0.70). The subdomain scores of pulmonary function (p < 0.01) and daily living (p < 0.01) significantly improved, whereas the subdomain scores of pain (p < 0.01), emotion (p < 0.01) and satisfaction (p = 0.02) significantly declined at last follow-up. CONCLUSION: The TGR procedure was associated with stable pulmonary function and decline in EOSQ-24 pain, emotion and satisfaction scores. LEVEL OF EVIDENCE: Level III, retrospective cohort study.

7.
Medicine (Baltimore) ; 100(24): e26291, 2021 Jun 18.
Article in English | MEDLINE | ID: mdl-34128864

ABSTRACT

ABSTRACT: Ultrasonography is the ideal tool for assessing hip morphology in infants younger than 6-month-old. This study assessed the interobserver agreement and clinical disparities of the 2 most widely used ultrasound (US) methods, the Graf method, and femoral head coverage (FHC) measurement.A prospective observational study (STROBE compliant) of 2024 newborns was conducted between January 2017 and December 2018. Hip US was conducted on all newborns with abnormal Barlow and Ortolani maneuvers as well as on 50 randomly selected normal newborns. The physical examination and US were performed by a senior pediatric orthopedic surgeon with musculoskeletal sonography certification. Three observers with different levels of experience interpreted the images by using the Graf method and FHC. We analyzed the intraclass correlation coefficient, Cohen kappa, and the disparity between the clinical findings of the 2 methods.A total of 198 newborns (9.8%) presented with clinical instability, including 193 subluxatable hips in 168 patients (84.8%) and 45 dislocatable/dislocated hips in 30 patients (15.2%). The mean age at US examination was 11.69 days (range: 0-18 days). The intraclass correlation coefficient was .71 (95% CI: 0.55-0.83) for FHC, 0.63 (95% CI: 0.38-0.78) for the alpha angle, and 0.47 (95% CI: 0.16-0.69) for beta angle. The Cohen kappa coefficients of Graf type were 0.19 (95% CI: 0.03-0.35), 0.39 (95% CI: 0.20-0.58), and 0.17 (95% CI: 0.02-0.32) between observers 1 and 2, observers 1 and 3, and observers 2 and 3, respectively. Based on the Graf method, 14% of the stable hips had abnormal USs; by contrast, 19.2% of the subluxatable hips and 17.8% of the dislocatable/dislocated hips had normal Graf morphologies. In USs interpreted using FHC, 16% of stable hips demonstrated abnormal coverage, whereas 13.5% of subluxatable hips and 4.4% of dislocatable/dislocated hips had normal FHC.Incidence of clinically detectable hip instability was 9.8% among newborns in our series. Both alpha angle and FHC ratio revealed substantial interobserver agreement while beta angle achieved moderate agreement. FHC ratio possesses higher sensitivity and similar specificity compared with the Graf method when screening unstable hips.Level II, development of diagnostic criteria on basis of consecutive patients.


Subject(s)
Anthropometry/methods , Developmental Dysplasia of the Hip/diagnosis , Neonatal Screening/methods , Physical Examination/statistics & numerical data , Ultrasonography/statistics & numerical data , Female , Femur Head/diagnostic imaging , Hip/diagnostic imaging , Humans , Infant, Newborn , Joint Instability/diagnosis , Male , Observer Variation , Physical Examination/methods , Prospective Studies , Sensitivity and Specificity , Ultrasonography/methods
8.
J Chin Med Assoc ; 84(4): 438-440, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33496516

ABSTRACT

BACKGROUND: The timing of post-operative full weight-bearing in patients of isolated displaced lateral malleolar fractures remains controversial. The aim of this study was to evaluate the outcomes of early full weight-bearing after rigid internal fixation of such fractures with locking plates. METHODS: From 2012 to 2018, 46 patients who had closed isolated displaced lateral malleolar fractures were included in the study. All fractures were managed with open reduction and internal fixation with locking plates. The patients were allowed to walk bearing their full weight 2 weeks after the operation. The follow-up period was 41.5 months on average (range: 12-70 months). The patients were available to evaluate union conditions, functional results, and complications. RESULTS: The fractures united smoothly with an average union time of 10.5 weeks (range: 8-16). At the final follow-up, the average American Orthopaedic Foot and Ankle Score Ankle-Hindfoot Score was 91 (range: 85-98). No complications were observed. CONCLUSION: For patients with isolated displaced lateral malleolar fractures, full weight-bearing is safe and effective, without an increase in the rate of complications, 2 weeks after open reduction and rigid fixation with locking plates.


Subject(s)
Ankle Fractures/surgery , Fracture Healing , Internal Fixators , Weight-Bearing , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Outcome Assessment, Health Care , Postoperative Period , Retrospective Studies , Young Adult
9.
J Chin Med Assoc ; 82(7): 584-588, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30893256

ABSTRACT

BACKGROUND: The cephalomedullary nail is the most common device used to treat unstable intertrochanteric fractures (ITFs) (AO/OTA 31-A2 and A3) in the geriatric population. However, there is lack of radiological parameter to evaluate the entry point; hence, this study reports a new radiological parameter to evaluate the entry point of the nail. Besides, other risk factors were also examined. METHODS: A retrospective study on the geriatric population with unstable ITFs was conducted from July 2011 to December 2014. A total of 136 patients were enrolled in this study; they received treatment with Gamma-3 nails (Stryker, Mahwah, NJ, USA) and were followed for at least 1 year. Demographic data, radiological parameters, and side-difference of the distance from the piriformis fossa to the greater trochanteric tubercle in the anteroposterior view (dPG) were compared between the union and failure groups. Student's t test, χ test, and multiple logistic regression were used in the statistical analyses. RESULTS: The overall failure rate was 13.23% (18 patients). Sex, tip-apex distance (TAD), and dPG were significantly different between the failure and union groups in multivariate analyses. Using a dPG > 6 mm as a reference, patients with a dPG > 6 mm had an odds ratio of 7.64 for failure relative to a dPG < 6 mm. CONCLUSION: This study provides additional evidence demonstrating that sex and TAD have significant effects on the outcomes of unstable ITFs after nailing. Moreover, the newly reported radiological parameter, dPG, can be used to predict the failure of ITFs treated using cephalomedullary nails.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary/methods , Hip Fractures/surgery , Aged , Aged, 80 and over , Female , Hip Fractures/diagnostic imaging , Humans , Logistic Models , Male , Retrospective Studies , Risk Factors , Treatment Failure
10.
J Chin Med Assoc ; 82(5): 419-423, 2019 May.
Article in English | MEDLINE | ID: mdl-30893260

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the influence of leg length discrepancy in geriatric patients with early failure of bipolar hemiarthroplasty and to identify related failure patterns and risk factors. METHODS: In this retrospective study, the risk factors of early acetabulum failure within 5 years of hemiarthroplasty for displaced femoral neck fracture were compared with a control group of patients who had implant survival for at least 5 years after hemiarthroplasty. The basic data, leg length discrepancy, femoral offset, and the shell size were evaluated. RESULTS: Of all risk factors, there was a significant difference in increased leg length between the two groups. The mean difference in leg length was 7.8 ± 5.9 mm in the early acetabular failure group and -1.7 ± 6.2 mm in the control group. For an increase in leg length of >6 mm, the odds ratio of early acetabular failure was 25-fold greater when compared with the control group. CONCLUSION: Increased leg length was significantly associated with early acetabular failure after bipolar hemiarthroplasty for femoral neck fracture among geriatric patients. It is critical to avoid increase in leg length after bipolar hemiarthroplasty.


Subject(s)
Acetabulum/surgery , Femoral Neck Fractures/surgery , Hemiarthroplasty/adverse effects , Postoperative Complications/etiology , Aged , Aged, 80 and over , Female , Femoral Neck Fractures/mortality , Humans , Leg Length Inequality/complications , Male , Middle Aged , Retrospective Studies , Risk Factors
11.
J Chin Med Assoc ; 82(6): 500-504, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30893266

ABSTRACT

BACKGROUND: We compared the clinical efficacy of normal C-reactive protein (CRP) expression (<1.0 mg/dL), with a 2-week drug holiday test (DHT) and no drug holiday test (DHT) as a reimplantation criterion, based on subsequent infections after a two-stage revision of a total knee arthroplasty of a periprosthetic joint infection (PJI). METHODS: In a 10-year review of 58 patients (mean age: 73.3-years-old; mean follow-up: 46.2 months), there were 31 patients in the DHT group and 27 patients in the DHT group. Primary outcome was recurrent infection rate. Secondary outcomes included length of hospital stay in the revision stage and CRP resurge one day before revision. RESULTS: We reported that the CRP resurge rate in the DHT group (0%) was significantly (p = 0.029) lower than that in the DHT group (16.1%) one day before the revision. The DHT group also had a significantly shorter mean length of stay (LOS) in the hospital (9.6 vs 12.7 days, p = 0.015) and a nonsignificantly lower subsequent infection rate (14.8% vs 29%, p = 0.195). CONCLUSION: We found that disciplined use of DHT as a reimplantation criterion reduced CRP resurges before reimplantation and yielded a shorter LOS afterward. DHT positively affected the subsequent mid-term infection rate after PJI treatment.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Prosthesis-Related Infections/drug therapy , Aged , Aged, 80 and over , C-Reactive Protein/analysis , Female , Humans , Length of Stay , Male , Middle Aged , Prosthesis-Related Infections/blood , Retrospective Studies
13.
J Shoulder Elbow Surg ; 27(2): 224-230, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29054381

ABSTRACT

BACKGROUND: Treatment of displaced distal clavicular fractures is still controversial. This study reports the utility of a new coracoclavicular (CC) loop technique for acute displaced distal clavicular fractures and compared its surgical outcomes with those of the hook plate method. METHODS: In this retrospective study, a total of 23 patients with acute displaced distal clavicular fractures were treated with a new CC loop technique at a single institution from 2010 to 2014. Another group comprising 49 patients treated with a hook plate was compared with the CC loop group regarding clinical and radiologic outcomes. RESULTS: Seventy-two patients with at least 1 year of follow-up after both operations were included in this study. The Constant score was significantly greater in the CC loop group (95 vs 87, P = .009) at final follow-up. Moreover, the complication rate was significantly lower in the CC loop group (0% vs 24.5%, P = .007). The University of California, Los Angeles shoulder score and radiologic nonunion rate revealed no significant differences between the 2 groups. CONCLUSIONS: The new CC loop technique had better clinical outcomes and lower complication rates compared with the hook plate technique.


Subject(s)
Bone Plates , Clavicle/surgery , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Adult , Clavicle/injuries , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...