Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Nat Biotechnol ; 41(2): 282-292, 2023 02.
Article in English | MEDLINE | ID: mdl-36163547

ABSTRACT

A fundamental challenge in fluorescence microscopy is the photon shot noise arising from the inevitable stochasticity of photon detection. Noise increases measurement uncertainty and limits imaging resolution, speed and sensitivity. To achieve high-sensitivity fluorescence imaging beyond the shot-noise limit, we present DeepCAD-RT, a self-supervised deep learning method for real-time noise suppression. Based on our previous framework DeepCAD, we reduced the number of network parameters by 94%, memory consumption by 27-fold and processing time by a factor of 20, allowing real-time processing on a two-photon microscope. A high imaging signal-to-noise ratio can be acquired with tenfold fewer photons than in standard imaging approaches. We demonstrate the utility of DeepCAD-RT in a series of photon-limited experiments, including in vivo calcium imaging of mice, zebrafish larva and fruit flies, recording of three-dimensional (3D) migration of neutrophils after acute brain injury and imaging of 3D dynamics of cortical ATP release. DeepCAD-RT will facilitate the morphological and functional interrogation of biological dynamics with a minimal photon budget.


Subject(s)
Photons , Zebrafish , Animals , Mice , Time-Lapse Imaging , Microscopy, Fluorescence , Signal-To-Noise Ratio
2.
Nat Comput Sci ; 3(12): 1067-1080, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38177722

ABSTRACT

Fluorescence imaging with high signal-to-noise ratios has become the foundation of accurate visualization and analysis of biological phenomena. However, the inevitable noise poses a formidable challenge to imaging sensitivity. Here we provide the spatial redundancy denoising transformer (SRDTrans) to remove noise from fluorescence images in a self-supervised manner. First, a sampling strategy based on spatial redundancy is proposed to extract adjacent orthogonal training pairs, which eliminates the dependence on high imaging speed. Second, we designed a lightweight spatiotemporal transformer architecture to capture long-range dependencies and high-resolution features at low computational cost. SRDTrans can restore high-frequency information without producing oversmoothed structures and distorted fluorescence traces. Finally, we demonstrate the state-of-the-art denoising performance of SRDTrans on single-molecule localization microscopy and two-photon volumetric calcium imaging. SRDTrans does not contain any assumptions about the imaging process and the sample, thus can be easily extended to various imaging modalities and biological applications.


Subject(s)
Calcium, Dietary , Self-Management , Humans , Electric Power Supplies , Optical Imaging , Photons
SELECTION OF CITATIONS
SEARCH DETAIL
...