Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
J Cancer Res Clin Oncol ; 150(5): 284, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38811379

ABSTRACT

PURPOSE: The study aims to investigate whether including the inflammation-related parameters would enhance the accuracy of a nomogram for local control (LC) prediction in lung cancer patients undergoing stereotactic body radiation therapy (SBRT). METHODS: 158 primary or metastatic lung cancer patients treated with SBRT were retrospectively analyzed. The clinical, dosimetric and inflammation-related parameters were collected for the Cox regression analysis. The ACPB model was constructed by employing the clinical and dosimetric factors. And the ACPBLN model was established by adding the inflammation-related factors to the ACPB model. The two models were compared in terms of ROC, Akaike Information Criterion (AIC), C-index, time-dependent AUC, continuous net reclassification index (NRI), integrated discrimination improvement (IDI), calibration plots and decision curve analysis (DCA). RESULTS: Multivariate Cox regression analysis revealed that six prognostic factors were independently associated with LC, including age, clinical stage, planning target volume (PTV) volume, BED of the prescribed dose (BEDPD), the lymphocyte count and neutrocyte count. The ACPBLN model performed better in AIC, bootstrap-corrected C-index, time-dependent AUC, NRI and IDI than the ACPB model. The calibration plots showed good consistency between the probabilities and observed values in the two models. The DCA curves showed that the ACPBLN nomogram had higher overall net benefit than the ACPB model across a majority of threshold probabilities. CONCLUSION: The inflammation-related parameters were associated with LC for lung cancer patients treated with SBRT. The inclusion of the inflammation-related parameters improved the predictive performance of the nomogram for LC prediction.


Subject(s)
Inflammation , Lung Neoplasms , Nomograms , Radiosurgery , Humans , Radiosurgery/methods , Lung Neoplasms/pathology , Lung Neoplasms/radiotherapy , Female , Male , Aged , Retrospective Studies , Middle Aged , Inflammation/pathology , Aged, 80 and over , Prognosis , Adult
2.
J Cancer Res Clin Oncol ; 150(2): 34, 2024 Jan 26.
Article in English | MEDLINE | ID: mdl-38277078

ABSTRACT

PURPOSE: The study aims to develop and validate a combined model for predicting 3-year cancer-specific survival (CSS) in lung cancer patients treated with stereotactic body radiation therapy (SBRT) by integrating clinical and radiomic parameters. METHODS: Clinical data and pre-treatment CT images were collected from 102 patients treated with lung SBRT. Multivariate logistic regression and the least absolute shrinkage and selection operator were used to determine the clinical and radiomic factors associated with 3-year CSS. Three prediction models were developed using clinical factors, radiomic factors, and a combination of both. The performance of the models was assessed using receiver operating characteristic curve and calibration curve. A nomogram was also created to visualize the 3-year CSS prediction. RESULTS: With a 36-month follow-up, 40 patients (39.2%) died of lung cancer and 62 patients (60.8%) survived. Three clinical factors, including gender, clinical stage, and lymphocyte ratio, along with three radiomic features, were found to be independent factors correlated with 3-year CSS. The area under the curve values for the clinical, radiomic, and combined model were 0.839 (95% CI 0.735-0.914), 0.886 (95% CI 0.790-0.948), and 0.914 (95% CI 0.825-0.966) in the training cohort, and 0.757 (95% CI 0.580-0.887), 0.818 (95% CI 0.648-0.929), and 0.843 (95% CI 0.677-0.944) in the validation cohort, respectively. Additionally, the calibration curve demonstrated good calibration performance and the nomogram created from the combined model showed potential for clinical utility. CONCLUSION: A clinical-radiomic model was developed to predict the 3-year CSS for lung cancer patients treated with SBRT.


Subject(s)
Lung Neoplasms , Radiosurgery , Humans , Lung Neoplasms/radiotherapy , Radiomics , Calibration , Death
3.
Clin Lung Cancer ; 24(8): e323-e331.e2, 2023 12.
Article in English | MEDLINE | ID: mdl-37648569

ABSTRACT

BACKGROUND: The study aims to identify the risk factors and develop a model for predicting grade ≥2 radiation pneumonitis (RP) for lung cancer patients treated with stereotactic body radiation therapy (SBRT). MATERIALS AND METHODS: Clinical data, dosimetric data, and laboratory biomarkers from 186 patients treated with lung SBRT were collected. Univariate and multivariate logistic regression were performed to determine the predictive factors for grade ≥2 RP. Three models were developed by using the clinical, dosimetric, and combined factors, respectively. RESULTS: With a median follow-up of 36 months, grade ≥2 RP was recorded in 13.4% of patients. On univariate logistic regression analysis, clinical factors of age and lung volume, dosimetric factors of treatment durations, fractional dose and V10, and laboratory biomarkers of neutrophil, PLT, PLR, and Hb levels were significantly associated with grade ≥2 RP. However, on multivariate analysis, only age, lung volume, fractional dose, V10, and Hb levels were independent factors. AUC values for the clinical, dosimetric, and combined models were 0.730 (95% CI, 0.660-0.793), 0.711 (95% CI, 0.641-0.775) and 0.830 (95% CI, 0.768-0.881), respectively. The combined model provided superior discriminative ability than the clinical and dosimetric models (P < .05). CONCLUSION: Age, lung volume, fractional dose, V10, and Hb levels were demonstrated to be significant factors associated with grade ≥2 RP for lung cancer patients after SBRT. A novel model combining clinical, dosimetric factors, and laboratory biomarkers improved predictive performance compared with the clinical and dosimetric model alone.


Subject(s)
Lung Neoplasms , Radiation Pneumonitis , Radiosurgery , Humans , Lung Neoplasms/surgery , Radiation Pneumonitis/diagnosis , Radiation Pneumonitis/epidemiology , Radiation Pneumonitis/etiology , Radiosurgery/adverse effects , Lung , Biomarkers
4.
Front Oncol ; 12: 863502, 2022.
Article in English | MEDLINE | ID: mdl-35299750

ABSTRACT

Purpose: Stereotactic body radiation therapy (SBRT) is a standard treatment for early primary lung cancer patients. However, there are few simple models for predicting the clinical outcomes of these patients. Our study analyzed the clinical outcomes, identified the prognostic factors, and developed prediction nomogram models for these patients. Materials and Methods: We retrospectively analyzed 114 patients with primary lung cancer treated with SBRT from 2012 to 2020 at our institutions and assessed patient's clinical outcomes and levels of toxicity. Kaplan-Meier analysis with a log-rank test was used to generate the survival curve. The cut-off values of continuous factors were calculated with the X-tile tool. Potential independent prognostic factors for clinical outcomes were explored using cox regression analysis. Nomograms for clinical outcomes prediction were established with identified factors and assessed by calibration curves. Results: The median overall survival (OS) was 40.6 months, with 3-year OS, local recurrence free survival (LRFS), distant disease-free survival (DDFS) and progression free survival (PFS) of 56.3%, 61.3%, 72.9% and 35.8%, respectively, with grade 3 or higher toxicity rate of 7%. The cox regression analysis revealed that the clinical stage, immobilization device, and the prescription dose covering 95% of the target area (D95) were independent prognostic factors associated with OS. Moreover, the clinical stage, and immobilization device were independent prognostic factors of LRFS and PFS. The smoking status, hemoglobin (Hb) and immobilization device were significant prognostic factors for DDFS. The nomograms and calibration curves incorporating the above factors indicated good predictive accuracy. Conclusions: SBRT is effective and safe for primary lung cancer. The prognostic factors associated with OS, LRFS, DDFS and PFS are proposed, and the nomograms we proposed are suitable for clinical outcomes prediction.

5.
Front Oncol ; 11: 819047, 2021.
Article in English | MEDLINE | ID: mdl-35174072

ABSTRACT

PURPOSE: Stereotactic body radiotherapy (SBRT) is an important treatment modality for lung cancer patients, however, tumor local recurrence rate remains some challenge and there is no reliable prediction tool. This study aims to develop a prediction model of local control for lung cancer patients undergoing SBRT based on radiomics signature combining with clinical and dosimetric parameters. METHODS: The radiomics model, clinical model and combined model were developed by radiomics features, incorporating clinical and dosimetric parameters and radiomics signatures plus clinical and dosimetric parameters, respectively. Three models were established by logistic regression (LR), decision tree (DT) or support vector machine (SVM). The performance of models was assessed by receiver operating characteristic curve (ROC) and DeLong test. Furthermore, a nomogram was built and was assessed by calibration curve, Hosmer-Lemeshow and decision curve. RESULTS: The LR method was selected for model establishment. The radiomics model, clinical model and combined model showed favorite performance and calibration (Area under the ROC curve (AUC) 0.811, 0.845 and 0.911 in the training group, 0.702, 0.786 and 0.818 in the validation group, respectively). The performance of combined model was significantly superior than the other two models. In addition, Calibration curve and Hosmer-Lemeshow (training group: P = 0.898, validation group: P = 0.891) showed good calibration of combined nomogram and decision curve proved its clinical utility. CONCLUSIONS: The combined model based on radiomics features plus clinical and dosimetric parameters can improve the prediction of 1-year local control for lung cancer patients undergoing SBRT.

6.
J Cancer ; 10(19): 4655-4661, 2019.
Article in English | MEDLINE | ID: mdl-31528230

ABSTRACT

Objective: The applicability of the linear quadratic (LQ) model to local control (LC) modeling after hypofractionated radiotherapy to treat lung cancer is highly debated. To date, the differences in predicted outcomes between the LQ model and other radiobiological models, which are characterized by additional dose modification beyond a certain transitional dose (dT), have not been well established. This study aims to compare the outcomes predicted by the LQ model with those predicted by two other radiobiological models in stereotactic body radiotherapy (SBRT) for non-small cell lung cancer (NSCLC). Methods: Computer tomography (CT) simulation data sets for 20 patients diagnosed with stage Ⅰ primary NSCLC were included in this study. Three radiobiological models, including the LQ, the universal survival curve (USC) and the modified linear quadratic and linear (mLQL) model were employed to predict the tumor control probability (TCP) data. First, the dT values for the USC and mLQL models were determined. Then, the biologically effective dose (BED) and the predicted TCP values from the LQ model were compared with those calculated from the USC and mLQL models. Results: The dT values from the USC model were 29.6 Gy, 33.8 Gy and 44.5 Gy, whereas the values were 90.2 Gy, 84.0 Gy and 57.3 Gy for the mLQL model for 1-year, 2-year and 3-year TCP prediction. The remarkable higher dT values obtained from the mLQL model revealed the same dose-response relationship as the LQ model in the low- and high-dose ranges. We also found that TCP prediction from the LQ and USC models differed by less than 3%, although the BED values for the two models were significantly different. Conclusion: Radiobiological analysis reveals small differences between the models and suggested that the LQ model is applicable for modeling LC using SBRT to treat lung cancer, even when an extremely high fractional dose is used.

7.
Radiat Oncol ; 14(1): 111, 2019 Jun 20.
Article in English | MEDLINE | ID: mdl-31221159

ABSTRACT

BACKGROUND: To calculate the individualized fraction regime (IFR) in stereotactic body radiotherapy (SBRT) for non-small cell lung cancer (NSCLC) patients using the uncomplicated tumor control probability (UTCP, P+) function. METHODS: Thirty-three patients with peripheral lung cancer or lung metastases who had undergone SBRT were analyzed. Treatment planning was performed using the dose regime of 48 Gy in 4 fractions. Dose volume histogram (DVH) data for the gross tumor volume (GTV), lung, chest wall (CW) and rib were exported and the dose bin was multiplied by a certain percentage of the dose in that bin which ranged from 1 to 200% in steps of 1%. For each dose fraction, P+ values were calculated by considering the tumor control probability (TCP), radiation-induced pneumonitis (RIP), chest wall pain (CWP) and radiation-induced rib fracture (RIRF). UTCP values as a function of physical dose were plotted and the maximum P+ values corresponded to the optimal therapeutic gain. The IFR in 3 fractions was also calculated with the same method by converting the dose using the linear quadratic (LQ) model. RESULTS: Thirty-three patients attained an IFR using the introduced methods. All the patients achieved a TCP value higher than 92.0%. The IFR ranged from 3 × 10.8 Gy to 3 × 12.5 Gy for 3 fraction regimes and from 4 × 9.2 Gy to 4 × 10.7 Gy for 4 fraction regimes. Four patients with typical tumor characteristics demonstrated that the IFR was patient-specific and could maximize the therapeutic gain. Patients with a large tumor had a lower TCP and UTCP and a smaller fractional dose than patients with a small tumor. Patients with a tumor adjacent to the organ at risk (OAR) or at a high risk of RIP had a lower UTCP and a smaller fractional dose compared with patients with a tumor located distant from the OAR. CONCLUSIONS: The proposed method is capable of predicting the IFR for NSCLC patients undergoing SBRT. Further validation in clinical samples is required.


Subject(s)
Algorithms , Carcinoma, Non-Small-Cell Lung/surgery , Lung Neoplasms/surgery , Models, Statistical , Organs at Risk/radiation effects , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Aged , Carcinoma, Non-Small-Cell Lung/pathology , Dose Fractionation, Radiation , Female , Humans , Image Processing, Computer-Assisted/methods , Lung Neoplasms/pathology , Male , Middle Aged , Prognosis , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods , Tomography, X-Ray Computed/methods
8.
Radiother Oncol ; 124(2): 256-262, 2017 08.
Article in English | MEDLINE | ID: mdl-28764926

ABSTRACT

PURPOSE: To develop and validate prediction models of overall survival (OS) for head and neck cancer (HNC) patients based on image biomarkers (IBMs) of the primary tumor and positive lymph nodes (Ln) in combination with clinical parameters. MATERIAL AND METHODS: The study cohort was composed of 289 nasopharyngeal cancer (NPC) patients from China and 298 HNC patients from the Netherlands. Multivariable Cox-regression analysis was performed to select clinical parameters from the NPC and HNC datasets, and IBMs from the NPC dataset. Final prediction models were based on both IBMs and clinical parameters. RESULTS: Multivariable Cox-regression analysis identified three independent IBMs (tumor Volume-density, Run Length Non-uniformity and Ln Major-axis-length). This IBM model showed a concordance(c)-index of 0.72 (95%CI: 0.65-0.79) for the NPC dataset, which performed reasonably with a c-index of 0.67 (95%CI: 0.62-0.72) in the external validation HNC dataset. When IBMs were added in clinical models, the c-index of the NPC and HNC datasets improved to 0.75 (95%CI: 0.68-0.82; p=0.019) and 0.75 (95%CI: 0.70-0.81; p<0.001), respectively. CONCLUSION: The addition of IBMs from the primary tumor and Ln improved the prognostic performance of the models containing clinical factors only. These combined models may improve pre-treatment individualized prediction of OS for HNC patients.


Subject(s)
Carcinoma/diagnosis , Carcinoma/mortality , Nasopharyngeal Neoplasms/diagnosis , Nasopharyngeal Neoplasms/mortality , Biomarkers, Tumor/analysis , Carcinoma/diagnostic imaging , Carcinoma/therapy , Cetuximab/therapeutic use , Chemoradiotherapy , China/epidemiology , Cohort Studies , Female , Humans , Male , Middle Aged , Multivariate Analysis , Nasopharyngeal Carcinoma , Nasopharyngeal Neoplasms/diagnostic imaging , Nasopharyngeal Neoplasms/therapy , Neoplasm Staging , Netherlands/epidemiology , Prognosis , Proportional Hazards Models , Radiotherapy Planning, Computer-Assisted , Retrospective Studies
9.
Biomed Res Int ; 2017: 1436573, 2017.
Article in English | MEDLINE | ID: mdl-28695127

ABSTRACT

PURPOSE: The consistency for predicting local control (LC) data using biophysical models for stereotactic body radiotherapy (SBRT) treatment of lung cancer is unclear. This study aims to compare the results calculated from different models using the treatment planning data. MATERIALS AND METHODS: Treatment plans were designed for 17 patients diagnosed with primary non-small cell lung cancer (NSCLC) using 5 different fraction schemes. The Martel model, Ohri model, and the Tai model were used to predict the 2-year LC value. The Gucken model, Santiago model, and the Tai model were employed to estimate the 3-year LC data. RESULTS: We found that the employed models resulted in completely different LC prediction except for the Gucken and the Santiago models which exhibited quite similar 3-year LC data. The predicted 2-year and 3-year LC values in different models were not only associated with the dose normalization but also associated with the employed fraction schemes. The greatest difference predicted by different models was up to 15.0%. CONCLUSIONS: Our results show that different biophysical models influence the LC prediction and the difference is not only correlated to the dose normalization but also correlated to the employed fraction schemes.


Subject(s)
Biophysical Phenomena , Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/radiotherapy , Models, Biological , Radiosurgery , Aged , Dose-Response Relationship, Radiation , Female , Humans , Male , Middle Aged
10.
Onco Targets Ther ; 10: 2209-2217, 2017.
Article in English | MEDLINE | ID: mdl-28458564

ABSTRACT

OBJECTIVE: To compare the radiobiological response between simultaneously dose-escalated and non-escalated intensity-modulated radiation therapy (DE-IMRT and NE-IMRT) for patients with upper thoracic esophageal cancer (UTEC) using radiobiological evaluation. METHODS: Computed tomography simulation data sets for 25 patients pathologically diagnosed with primary UTEC were used in this study. DE-IMRT plan with an escalated dose of 64.8 Gy/28 fractions to the gross tumor volume (GTV) and involved lymph nodes from 25 patients pathologically diagnosed with primary UTEC, was compared to an NE-IMRT plan of 50.4 Gy/28 fractions. Dose-volume metrics, tumor control probability (TCP), and normal tissue complication probability for the lung and spinal cord were compared. In addition, the risk of acute esophageal toxicity (AET) and late esophageal toxicity (LET) were also analyzed. RESULTS: Compared with NE-IMRT plan, we found the DE-IMRT plan resulted in a 14.6 Gy dose escalation to the GTV. The tumor control was predicted to increase by 31.8%, 39.1%, and 40.9% for three independent TCP models. The predicted incidence of radiation pneumonitis was similar (3.9% versus 3.6%), and the estimated risk of radiation-induced spinal cord injury was extremely low (<0.13%) in both groups. Regarding the esophageal toxicities, the estimated grade ≥2 and grade ≥3 AET predicted by the Kwint model were increased by 2.5% and 3.8%. Grade ≥2 AET predicted using the Wijsman model was increased by 14.9%. The predicted incidence of LET was low (<0.51%) in both groups. CONCLUSION: Radiobiological evaluation reveals that the DE-IMRT dosing strategy is feasible for patients with UTEC, with significant gains in tumor control and minor or clinically acceptable increases in radiation-induced toxicities.

11.
Sci Rep ; 7(1): 120, 2017 03 09.
Article in English | MEDLINE | ID: mdl-28273921

ABSTRACT

We aim to evaluate whether different definitions of esophagus (DEs) impact on the esophageal toxicity prediction for esophageal cancer (EC) patients administered intensity-modulated radiation therapy with simultaneous integrated boost (SIB-IMRT) vs. standard-dose IMRT (SD-IMRT). The esophagus for 21 patients diagnosed with primary EC were defined in the following four ways: the whole esophagus, including the tumor (ESOwhole); ESOwhole within the treatment field (ESOinfield); ESOinfield, excluding the tumor (ESOinfield-tumor) and ESOwhole, excluding the tumor (ESOwhole-tumor). The difference in the dose variation, acute esophageal toxicity (AET) and late esophageal toxicity (LET) of four DEs were compared. We found that the mean esophageal dose for ESOwhole, ESOinfield, ESOinfield-tumor and ESOwhole-tumor were increased by 7.2 Gy, 10.9 Gy, 4.6 Gy and 2.0 Gy, respectively, in the SIB-IMRT plans. Radiobiological models indicated that a grade ≥ 2 AET was 2.9%, 3.1%, 2.2% and 1.6% higher on average with the Kwint model and 14.6%, 13.2%, 7.2% and 3.4% higher with the Wijsman model for the four DEs. A grade ≥ 3 AET increased by 4.3%, 7.2%, 4.2% and 1.2%, respectively. Additionally, the predicted LET increased by 0.15%, 0.39%, 1.2 × 10-2% and 1.5 × 10-3%. Our study demonstrates that different DEs influence the esophageal toxicity prediction for EC patients administered SIB-IMRT vs. SD-IMRT treatment.


Subject(s)
Esophageal Neoplasms/radiotherapy , Esophagus/radiation effects , Radiotherapy, Intensity-Modulated/adverse effects , Aged , Computer Simulation , Female , Humans , Male , Middle Aged , Terminology as Topic
12.
Sci Rep ; 6: 25959, 2016 05 13.
Article in English | MEDLINE | ID: mdl-27173670

ABSTRACT

This study aimed to investigate the dosimetric characteristics of an isocentrically shielded RapidArc (IS-RA) technique for treatment of locally recurrent nasopharyngeal cancer (lrNPC). In IS-RA, the isocenter was placed at the center of the pre-irradiated brainstem (BS)/spinal cord (SC) and the jaws were set to shield the BS/SC while ensuring the target coverage during the whole gantry rotation. For fifteen patients, the IS-RA plans were compared with the conventional RapidArc (C-RA) regarding target coverage, organ-at-risk (OAR) sparing and monitor units (MUs). The relationship between the dose reduction of BS/SC and some geometric parameters including the angle extended by the target with respect to the axis of BS/SC (Ang_BSSC), the minimum distance between the target and BS/SC (Dist_Min) and the target volume were evaluated. The IS-RA reduced the BS/SC doses by approximately 1-4 Gy on average over the C-RA, with more MUs. The IS-RA demonstrated similar target coverage and sparing of other OARs except for slightly improved sparing of optic structures. More dose reduction in the isocentric region was observed in the cases with larger Ang_BSSC or smaller Dist_Min. Our results indicated that the IS-RA significantly improves the sparing of BS/SC without compromising dosimetric requirements of other involved structures for lrNPC.


Subject(s)
Nasopharyngeal Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Radiometry , Radiotherapy Dosage , Recurrence , Young Adult
13.
Oncotarget ; 7(26): 40746-40755, 2016 Jun 28.
Article in English | MEDLINE | ID: mdl-27203739

ABSTRACT

This study aims to compare the radiobiological response of two stereotactic body radiotherapy (SBRT) schedules for patients with stage I peripheral non-small cell lung cancer (NSCLC) using radiobiological modeling methods. Volumetric modulated arc therapy (VMAT)-based SBRT plans were designed using two dose schedules of 1 × 34 Gy (34 Gy in 1 fraction) and 4 × 12 Gy (48 Gy in 4 fractions) for 19 patients diagnosed with primary stage I NSCLC. Dose to the gross target volume (GTV), planning target volume (PTV), lung and chest wall (CW) were converted to biologically equivalent dose in 2 Gy fraction (EQD2) for comparison. Five different radiobiological models were employed to predict the tumor control probability (TCP) value. Three additional models were utilized to estimate the normal tissue complication probability (NTCP) value for the lung and the modified equivalent uniform dose (mEUD) value to the CW. Our result indicates that the 1 × 34 Gy dose schedule provided a higher EQD2 dose to the tumor, lung and CW. Radiobiological modeling revealed that the TCP value for the tumor, NTCP value for the lung and mEUD value for the CW were 7.4% (in absolute value), 7.2% (in absolute value) and 71.8% (in relative value) higher on average, respectively, using the 1 × 34 Gy dose schedule.


Subject(s)
Carcinoma, Non-Small-Cell Lung/metabolism , Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/metabolism , Lung Neoplasms/radiotherapy , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Adult , Aged , Dose Fractionation, Radiation , Female , Humans , Lung/radiation effects , Male , Middle Aged , Probability , Radiometry , Radiotherapy Dosage , Tomography, X-Ray Computed
14.
PLoS One ; 11(5): e0156675, 2016.
Article in English | MEDLINE | ID: mdl-27231871

ABSTRACT

PURPOSE: To study the dosimetric difference between fixed-jaw volumetric modulated radiotherapy (FJ-VMAT) and large-field volumetric modulated radiotherapy (LF-VMAT) for nasopharyngeal carcinoma (NPC) with cervical lymph node metastasis. METHODS: Computed tomography (CT) datasets of 10 NPC patients undergoing chemoradiotherapy were used to generate LF-VMAT and FJ-VMAT plans in the Eclipse version 10.0 treatment planning system. These two kinds of plans were then compared with respect to planning-target-volume (PTV) coverage, conformity index (CI), homogeneity index (HI), organ-at-risk sparing, monitor units (MUs) and treatment time (TT). RESULTS: The FJ-VMAT plans provided lower D2% of PGTVnd (PTV of lymph nodes), PTV1 (high-risk PTV) and PTV2 (low-risk PTV) than did the LF-VMAT plans, whereas no significant differences were observed in PGTVnx (PTV of primary nasopharyngeal tumor). The FJ-VMAT plans provided lower doses delivered to the planning organ at risk (OAR) volumes (PRVs) of both brainstem and spinal cord, both parotid glands and normal tissue than did the LF-VMAT plans, whereas no significant differences were observed with respect to the oral cavity and larynx. The MUs of the FJ-VMAT plans (683 ± 87) were increased by 22% ± 12% compared with the LF-VMAT plans (559 ± 62). In terms of the TT, no significant difference was found between the two kinds of plans. CONCLUSIONS: FJ-VMAT was similar or slightly superior to LF-VMAT in terms of PTV coverage and was significantly superior in terms of OAR sparing, at the expense of increased MUs.


Subject(s)
Carcinoma/pathology , Carcinoma/radiotherapy , Nasopharyngeal Neoplasms/pathology , Nasopharyngeal Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Adult , Aged , Female , Humans , Lymphatic Metastasis , Male , Middle Aged , Nasopharyngeal Carcinoma , Organs at Risk/radiation effects , Radiometry , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/instrumentation , Young Adult
15.
Sci Rep ; 6: 23543, 2016 Mar 24.
Article in English | MEDLINE | ID: mdl-27009235

ABSTRACT

This study aimed to evaluate the dosimetric outcomes of a base-dose-plan-compensation (BDPC) planning method for improving intensity-modulated radiotherapy (IMRT) for stage III lung cancer. For each of the thirteen included patients, three types of planning methods were applied to obtain clinically acceptable plans: (1) the conventional optimization method (CO); (2) a split-target optimization method (STO), in which the optimization objectives were set higher dose for the target with lung density; (3) the BDPC method, which compensated for the optimization-convergence error by further optimization based on the CO plan. The CO, STO and BDPC methods were then compared regarding conformity index (CI), homogeneity index (HI) of the target, organs at risk (OARs) sparing and monitor units (MUs). The BDPC method provided better HI/CI by 54%/7% on average compared to the CO method and by 38%/3% compared to the STO method. The BDPC method also spared most of the OARs by up to 9%. The average MUs of the CO, STO and BDPC plans were 890, 937 and 1023, respectively. Our results indicated that the BDPC method can effectively improve the dose distribution in IMRT for stage III lung cancer, at the expense of more MUs.


Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Female , Humans , Male , Neoplasm Staging , Organs at Risk/radiation effects , Radiotherapy Dosage , Treatment Outcome
16.
PLoS One ; 11(1): e0146604, 2016.
Article in English | MEDLINE | ID: mdl-26734731

ABSTRACT

PURPOSE: To evaluate the dosimetric impacts of flattening filter-free (FFF) beams in intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for sinonasal cancer. METHODS: For fourteen cases, IMRT and VMAT planning was performed using 6-MV photon beams with both conventional flattened and FFF modes. The four types of plans were compared in terms of target dose homogeneity and conformity, organ-at-risk (OAR) sparing, number of monitor units (MUs) per fraction, treatment time and pure beam-on time. RESULTS: FFF beams led to comparable target dose homogeneity, conformity, increased number of MUs and lower doses to the spinal cord, brainstem and normal tissue, compared with flattened beams in both IMRT and VMAT. FFF beams in IMRT resulted in improvements by up to 5.4% for sparing of the contralateral optic structures, with shortened treatment time by 9.5%. However, FFF beams provided comparable overall OAR sparing and treatment time in VMAT. With FFF mode, VMAT yielded inferior homogeneity and superior conformity compared with IMRT, with comparable overall OAR sparing and significantly shorter treatment time. CONCLUSIONS: Using FFF beams in IMRT and VMAT is feasible for the treatment of sinonasal cancer. Our results suggest that the delivery mode of FFF beams may play an encouraging role with better sparing of contralateral optic OARs and treatment efficiency in IMRT, but yield comparable results in VMAT.


Subject(s)
Nose Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Adult , Aged , Female , Humans , Male , Middle Aged , Organs at Risk , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy, Intensity-Modulated/instrumentation
17.
Sci Rep ; 5: 18010, 2015 Dec 11.
Article in English | MEDLINE | ID: mdl-26657569

ABSTRACT

This study aimed to determine the optimal fraction scheme (FS) in patients with small peripheral non-small cell lung cancer (NSCLC) undergoing stereotactic body radiotherapy (SBRT) with the 4 × 12 Gy scheme as the reference. CT simulation data for sixteen patients diagnosed with primary NSCLC or metastatic tumor with a single peripheral lesion ≤3 cm were used in this study. Volumetric modulated arc therapy (VMAT) plans were designed based on ten different FS of 1 × 25 Gy, 1 × 30 Gy, 1 × 34 Gy, 3 × 15 Gy, 3 × 18 Gy, 3 × 20 Gy, 4 × 12 Gy, 5 × 12 Gy, 6 × 10 Gy and 10 × 7 Gy. Five different radiobiological models were employed to predict the tumor control probability (TCP) value. Three other models were utilized to estimate the normal tissue complication probability (NTCP) value to the lung and the modified equivalent uniform dose (mEUD) value to the chest wall (CW). The 1 × 30 Gy regimen is recommended to achieve 4.2% higher TCP and slightly higher NTCP and mEUD values to the lung and CW compared with the 4 × 12 Gy schedule, respectively. This regimen also greatly shortens the treatment duration. However, the 3 × 15 Gy schedule is suggested in patients where the lung-to-tumor volume ratio is small or where the tumor is adjacent to the CW.


Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Dose Fractionation, Radiation , Lung Neoplasms/radiotherapy , Models, Theoretical , Radiotherapy, Intensity-Modulated , Adult , Aged , Algorithms , Carcinoma, Non-Small-Cell Lung/diagnosis , Female , Humans , Lung Neoplasms/diagnosis , Male , Middle Aged , Neoplasm Staging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Retrospective Studies , Tomography, X-Ray Computed , Tumor Burden
18.
Sci Rep ; 5: 18453, 2015 Dec 18.
Article in English | MEDLINE | ID: mdl-26679747

ABSTRACT

The increasingly attractive stereotactic body radiotherapy (SBRT) treatment for stage I lung cancer is concomitant with a large amount of monitor units (MU), leading to excessive out-of-field dose and prolonged beam-on time. The study aims to reduce the MU number and shorten the beam-on time by optimizing the planning parameters. Clinically acceptable treatment plans from fourteen patients suffered from peripheral stage I non-small cell lung cancer (NSCLC) were created in the study. Priority for the upper objective of the target (PUOT), strength and Max MU setting in the MU objective function (MUOF) were adjusted respectively to investigate their effect on MU number, organs at risk (OARs) sparing and beam-on time. We found that the planning parameters influenced the MU number in a PUOT, strength and Max MU dependent manner. Combined with high priority for the UOT (HPUOT) and MUOF, the MU number was reduced from 443 ± 25 to 228 ± 22 MU/Gy without compromising the target coverage and OARs sparing. We also found beam-on time was proportional to MU number and it could be shortened from 7.9 ± 0.5 to 4.1 ± 0.4 minutes.


Subject(s)
Carcinoma, Non-Small-Cell Lung/surgery , Lung Neoplasms/surgery , Aged , Carcinoma, Non-Small-Cell Lung/pathology , Female , Humans , Lung Neoplasms/pathology , Male , Middle Aged , Neoplasm Staging , Organs at Risk/pathology , Radiosurgery , Radiotherapy Dosage , Retrospective Studies , Tomography, X-Ray Computed
19.
Sci Rep ; 5: 15361, 2015 Oct 26.
Article in English | MEDLINE | ID: mdl-26497620

ABSTRACT

Homogeneous target dose distribution in intensity-modulated radiotherapy (IMRT) for sinonasal cancer (SNC) is challenging to achieve. To solve this problem, we established and evaluated a basal-dose-compensation (BDC) optimization approach, in which the treatment plan is further optimized based on the initial plans. Generally acceptable initial IMRT plans for thirteen patients were created and further optimized individually by (1) the BDC approach and (2) a local-dose-control (LDC) approach, in which the initial plan is further optimized by addressing hot and cold spots. We compared the plan qualities, total planning time and monitor units (MUs) among the initial, BDC, LDC IMRT plans and volumetric modulated arc therapy (VMAT) plans. The BDC approach provided significantly superior dose homogeneity/conformity by 23%-48%/6%-9% compared with both the initial and LDC IMRT plans, as well as reduced doses to the organs at risk (OARs) by up to 18%, with acceptable MU numbers. Compared with VMAT, BDC IMRT yielded superior homogeneity, inferior conformity and comparable overall OAR sparing. The planning of BDC, LDC IMRT and VMAT required 30, 59 and 58 minutes on average, respectively. Our results indicated that the BDC optimization approach can achieve significantly better dose distributions with shorter planning time in the IMRT for SNC.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Paranasal Sinuses/pathology , Radiotherapy Dosage , Adult , Aged , Female , Humans , Male , Middle Aged
20.
PLoS One ; 10(7): e0127501, 2015.
Article in English | MEDLINE | ID: mdl-26131554

ABSTRACT

PURPOSE: To investigate the performance of using partial arc (PA) and full arc with avoidance sectors (FAAS) in stereotactic body radiotherapy (SBRT) of peripheral lung cancer with flattening filter free (FFF) beams. METHODS: Eighteen patients with primary (T1 or T2) non-small-cell lung cancer (NSCLC) or lung metastatic were selected for this study. Nine patients with a gross tumor volume (GTV) <= 10 cc were designated as the small tumor group. The other nine patients with a GTV between 10 cc and 44 cc were assigned to the large tumor group. The treatment plans were generated in eighteen patients using PA and FAAS techniques, respectively, and delivered with a Varian TrueBeam Linac. Dosimetry of the target and organs at risk (OARs), monitor unit (MU), out-of-field dose, and delivery time were statistically analyzed. Delta4 and portal dosimetry were employed to evaluate the delivery accuracy. RESULTS: For the small tumor group, compared with the PA plans, the FAAS plans significantly achieved a lower MU/fraction, out-of-field dose and a shorter treatment time (p<0.05), but the target dose was slightly higher than that delivered by PA plans (p<0.05). For the large tumor group, the PA plans significantly attained a shorter treatment time (p<0.05), whereas MU/fraction, out-of-field dose and dose to OARs were comparable between the two plans (p>0.05). Furthermore, all plans generated from the eighteen patients achieved a high pass rate in patient-specific quality assurance, with all the gamma indices greater than 97% at the Γ3mm, 3% threshold. CONCLUSION: This study suggests that the FAAS technique is more beneficial for the small tumor patients undergoing lung SBRT with FFF beams because of its higher treatment efficiency and MU reduction. However, for the large tumor patients, the PA technique is recommended due to its higher treatment efficiency.


Subject(s)
Lung Neoplasms/pathology , Lung Neoplasms/surgery , Radiosurgery/methods , Adult , Aged , Aged, 80 and over , Carcinoma, Non-Small-Cell Lung/pathology , Carcinoma, Non-Small-Cell Lung/surgery , Female , Humans , Male , Middle Aged , Neoplasm Staging , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...