Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Opt Express ; 32(11): 20401-20411, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38859152

ABSTRACT

A FMCW LiDAR system of both the distributed feedback laser and external cavity laser is established in baseband beat notes, rather than up-conversion to an intermediate frequency to exclude flicker noise. Meanwhile, utilizing fast-scanning MEMS mirrors, high-quality real-time (1 fps) 4-D images of the slow-moving object (10 mm/s) can be directly constructed at the baseband with a central frequency as low as 100 kHz and a small Doppler shift. The proposed LiDAR architecture based on such a low-frequency baseband significantly improves the optical power budget on the transmitter side and eliminates the costly high-speed sampling circuits on the receiver side.

2.
PLoS One ; 19(5): e0299602, 2024.
Article in English | MEDLINE | ID: mdl-38696439

ABSTRACT

PURPOSE: The purposes of this study were to determine whether biomechanical properties of mature oocytes could predict usable blastocyst formation better than morphological information or maternal factors, and to demonstrate the safety of the aspiration measurement procedure used to determine the biomechanical properties of oocytes. METHODS: A prospective split cohort study was conducted with patients from two IVF clinics who underwent in vitro fertilization. Each patient's oocytes were randomly divided into a measurement group and a control group. The aspiration depth into a micropipette was measured, and the biomechanical properties were derived. Oocyte fertilization, day 3 morphology, and blastocyst development were observed and compared between measured and unmeasured cohorts. A predictive classifier was trained to predict usable blastocyst formation and compared to the predictions of four experienced embryologists. RESULTS: 68 patients and their corresponding 1252 oocytes were included in the study. In the safety analyses, there was no significant difference between the cohorts for fertilization, while the day 3 and 5 embryo development were not negatively affected. Four embryologists predicted usable blastocyst development based on oocyte morphology with an average accuracy of 44% while the predictive classifier achieved an accuracy of 71%. Retaining the variables necessary for normal fertilization, only data from successfully fertilized oocytes were used, resulting in a classifier an accuracy of 81%. CONCLUSIONS: To date, there is no standard guideline or technique to aid in the selection of oocytes that have a higher likelihood of developing into usable blastocysts, which are chosen for transfer or vitrification. This study provides a comprehensive workflow of extracting biomechanical properties and building a predictive classifier using these properties to predict mature oocytes' developmental potential. The classifier has greater accuracy in predicting the formation of usable blastocysts than the predictions provided by morphological information or maternal factors. The measurement procedure did not negatively affect embryo culture outcomes. While further analysis is necessary, this study shows the potential of using biomechanical properties of oocytes to predict embryo developmental outcomes.


Subject(s)
Blastocyst , Embryonic Development , Fertilization in Vitro , Oocytes , Humans , Blastocyst/physiology , Blastocyst/cytology , Female , Oocytes/physiology , Oocytes/cytology , Adult , Biomechanical Phenomena , Fertilization in Vitro/methods , Embryonic Development/physiology , Prospective Studies
3.
Biosens Bioelectron ; 258: 116353, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38696966

ABSTRACT

Male infertility is a pervasive global reproductive challenge, primarily attributed to a decline in semen quality. Addressing this concern, there has been a growing focus on spermatozoa sorting in assisted reproductive technology. This study introduces a groundbreaking development in the form of a thermotaxis and rheotaxis microfluidic (TRMC) device designed for efficient motile spermatozoa sorting within a short 15-min timeframe. The TRMC device mimics the natural sperm sorting mechanism of the oviduct, selecting spermatozoa with superior motility and DNA integrity. The experimental outcomes demonstrate a remarkable enhancement in the percentage of progressive spermatozoa following sorting, soaring from 3.90% to an impressive 96.11% when subjected to a temperature decrease from 38 °C to 35 °C. Notably, sperm motility exhibited a substantial 69% improvement. The TRMC device exhibited a commendable recovery rate of 60.93%, surpassing current clinical requirements. Furthermore, the sorted spermatozoa displayed a notable reduction in the DNA fragmentation index to 6.94%, signifying a substantial 90% enhancement in DNA integrity. This remarkable advancement positions the TRMC device as highly suitable for applications in in vitro fertilization (IVF) and intracytoplasmic sperm injection (ICSI), offering a promising solution to male infertility challenges.


Subject(s)
Lab-On-A-Chip Devices , Sperm Motility , Spermatozoa , Male , Spermatozoa/physiology , Spermatozoa/cytology , Humans , Equipment Design , Infertility, Male , Biosensing Techniques/instrumentation , Cell Separation/instrumentation , DNA Fragmentation , Temperature
4.
Int J Mol Sci ; 25(7)2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38612482

ABSTRACT

Despite serum progesterone being a widely accepted method for luteal phase support during embryo transfer cycles, debates persist regarding the optimal strategy for guiding clinical decisions on progesterone dosages to maximize reproductive outcomes. This retrospective study explored the utility of microRNA (miRNA) biomarkers in guiding personalized progesterone dosage adjustments for frozen embryo transfer (FET) cycles in 22 in vitro fertilization (IVF) patients undergoing hormone replacement therapy. Utilizing MIRA, an miRNA-based endometrial receptivity test, we analyzed patients' miRNA expression profiles before and after progesterone dosage adjustments to determine suitable dosages and assess endometrial status. Despite patients receiving identical progesterone dosages, variations in miRNA profiles were observed in the initial cycle, and all patients presented a displaced window of implantation. Following dosage adjustments based on their miRNA profiles, 91% of patients successfully transitioned their endometrium towards the receptive stages. However, two patients continued to exhibit persistent displaced receptivity despite the adjustments. Given the evident variation in endometrial status and serum progesterone levels among individuals, analyzing miRNA expression profiles may address the challenge of inter-personal variation in serum progesterone levels, to deliver more personalized dosage adjustments and facilitate personalized luteal phase support in IVF.


Subject(s)
MicroRNAs , Progesterone , Female , Humans , Luteal Phase , Retrospective Studies , MicroRNAs/genetics , Embryo Transfer , Endometrium
5.
Bioengineering (Basel) ; 11(4)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38671799

ABSTRACT

OBJECTIVES: This study aimed to establish reference values for fetal aortic isthmus blood flow velocity and associated indices during the first trimester, utilizing a novel ultrasonographic technique known as high-definition flow imaging (HDFI). Additionally, the correlation between Doppler profiles of aortic blood flow and key fetal parameters, including nuchal thickness (NT), crown-rump length (CRL), and fetal heartbeat (FHB), was investigated. METHODS: A total of 262 fetuses were included in the analysis between December 2022 and December 2023. Utilizing 2D power Doppler ultrasound images, aortic blood flow parameters were assessed, including aortic peak systolic velocity (PS), aortic end-diastolic velocity (ED), aortic time average maximal velocity (TAMV), and various indices such as aortic systolic velocity/diastolic velocity (S/D), aortic pulsatile index (PI), aortic resistance index (RI), aortic isthmus flow velocity index (IFI), and aortic isthmic systolic index (ISI). Concurrently, fetal FHB, NT, and CRL were evaluated during early trimester Down syndrome screening. RESULTS: Significant findings include a positive correlation between gestational age (GA) and PS (PS = 3.75 × (GA) - 15.4, r2 = 0.13, p < 0.01), ED (ED = 0.42 × (GA) - 0.61, r2 = 0.04, p < 0.01), PI (PI = 0.07 × (GA) + 1.03, r2 = 0.04, p < 0.01), and TAMV (TAMV = 1.23 × (GA) - 1.66, r2 = 0.08, p < 0.01). In contrast, aortic ISI demonstrated a significant decrease (ISI = -0.03 × (GA) + 0.57, r2 = 0.05, p < 0.05) with gestational age. No significant correlation was observed for aortic RI (p = 0.33), S/D (p = 0.39), and IFI (p = 0.29) with gestational age. Aortic PS exhibited positive correlations with NT (0.217, p = 0.001) and CRL (0.360, p = 0.000) but a negative correlation with FHB (-0.214, p = 0.001). Aortic PI demonstrated positive correlations with CRL (0.208, p = 0.001) and negative correlations with FHB (-0.176, p = 0.005). Aortic TAMV showed positive correlations with NT (0.233, p = 0.000) and CRL (0.290, p = 0.000) while exhibiting a negative correlation with FHB (-0.141, p = 0.026). Aortic ISI demonstrated negative correlations with NT (-0.128, p = 0.045) and CRL (-0.218, p = 0.001) but a positive correlation with FHB (0.163, p = 0.010). CONCLUSIONS: Power Doppler angiography with Doppler ultrasound demonstrates the ability to establish accurate reference values for fetal aortic blood flow during the first trimester of pregnancy. Notably, aortic PS, TAMV, and ISI exhibit significant correlations with NT, CRL, and FHB, with ISI appearing more relevant than IFI, PS, TAMV, and FHB. The utilization of HDFI technology proves advantageous in efficiently detecting the site of the aortic isthmus compared to traditional color Doppler mode in early second trimesters.

6.
Biomedicines ; 12(3)2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38540313

ABSTRACT

Though tremendous advances have been made in the field of in vitro fertilization (IVF), a portion of patients are still affected by embryo implantation failure issues. One of the most significant factors contributing to implantation failure is a uterine condition called displaced window of implantation (WOI), which refers to an unsynchronized endometrium and embryo transfer time for IVF patients. Previous studies have shown that microRNAs (miRNAs) can be important biomarkers in the reproductive process. In this study, we aim to develop a miRNA-based classifier to identify the WOI for optimal time for embryo transfer. A reproductive-related PanelChip® was used to obtain the miRNA expression profiles from the 200 patients who underwent IVF treatment. In total, 143 out of the 167 miRNAs with amplification signals across 90% of the expression profiles were utilized to build a miRNA-based classifier. The microRNA-based classifier identified the optimal timing for embryo transfer with an accuracy of 93.9%, a sensitivity of 85.3%, and a specificity of 92.4% in the training set, and an accuracy of 88.5% in the testing set, showing high promise in accurately identifying the WOI for the optimal timing for embryo transfer.

7.
Opt Express ; 31(16): 26463-26473, 2023 Jul 31.
Article in English | MEDLINE | ID: mdl-37710507

ABSTRACT

The enhancement in responsivity of photodiodes (PDs) or avalanche photodiodes (APDs) with the traditional flip-chip bonding package usually comes at the expense of degradation in the optical-to-electrical (O-E) bandwidth due to the increase of parasitic capacitance. In this work, we demonstrate backside-illuminated In0.52Al0.48As based APDs with novel flip-chip bonding packaging designed to relax this fundamental trade-off. The inductance induced peak in the measured O-E frequency response of these well-designed and well-packaged APDs, which can be observed around its 3-dB bandwidth (∼30 GHz), effectively widens the bandwidth and becomes more pronounced when the active diameter of the APD is aggressively downscaled to as small as 3 µm. With a typical active window diameter of 14 µm, large enough for alignment tolerance and low optical coupling loss, the packaged APD exhibits a moderate damping O-E frequency response with a bandwidth (36 vs. 31 GHz) and responsivity (3.4 vs. 2.3 A/W) superior to those of top-illuminated reference sample under 0.9 Vbr operation, to attain a high millimeter wave output power (0 dBm at 40 GHz) and output current (12.5 mA at +8.8 dBm optical power). The excellent static and dynamic performance of this design open up new possibilities to further improve the sensitivity at the receiver-end of the next-generation of passive optical network (PON) and coherent communication systems.

8.
iScience ; 26(8): 107356, 2023 Aug 18.
Article in English | MEDLINE | ID: mdl-37559897

ABSTRACT

Assisted reproductive technology (ART) is an important invention for the treatment of human infertility, and the isolation of high-quality sperm with progressive motility is one of the most critical steps that eventually affect the fertilization rate. Conventional sperm separation approaches include the swim-up method and density gradient centrifugation. However, the quality of isolated sperm obtained from both approaches can still be improved by improving sorted sperm motility, minimizing the DNA fragmentation rate, and removing abnormal phenotypes. Here, we report a Progressive Sperm Sorting Chip (PSSC) for high-quality sperm isolation. Based on the rheotaxis behavior of sperm, a gradient flow field is created in the chip for progressive sperm sorting. Clinical experiment results for 10 volunteers showed that greater than 90% of isolated sperm exhibit high motility (> 25 µm/s), high linearity (0.8), and a very low DNA fragmentation rate (< 5%). In addition, the whole process is label and chemical free. These features aid in gentle sperm sorting to obtain healthy sperm. This device uniquely enables the selection of high-quality sperm with progressive motility and might be clinically applied for infertility treatment in the near future.

9.
Int J Mol Sci ; 25(1)2023 Dec 20.
Article in English | MEDLINE | ID: mdl-38203247

ABSTRACT

MicroRNAs (miRNAs) can regulate the expression of genes involved in the establishment of the window of implantation (WOI) in the endometrium. Recent studies indicated that cell-free miRNAs in uterine fluid and blood samples could act as alternative and non-invasive sample types for endometrial receptivity analysis. In this study, we attempt to systematically evaluate whether the expression levels of cell-free microRNAs in blood samples could be used as non-invasive biomarkers for assessing endometrial receptivity status. We profiled the miRNA expression levels of 111 blood samples using next-generation sequencing to establish a predictive model for the assessment of endometrial receptivity status. This model was validated with an independent dataset (n = 73). The overall accuracy is 95.9%. Specifically, we achieved accuracies of 95.9%, 95.9%, and 100.0% for the pre-receptive group, the receptive group, and the post-respective group, respectively. Additionally, we identified a set of differentially expressed miRNAs between different endometrial receptivity statuses using the following criteria: p-value < 0.05 and fold change greater than 1.5 or less than -1.5. In conclusion, the expression levels of cell-free miRNAs in blood samples can be utilized in a non-invasive manner to distinguish different endometrial receptivity statuses.


Subject(s)
Circulating MicroRNA , MicroRNAs , Female , Humans , Embryo Implantation/genetics , Embryo Transfer , Endometrium , MicroRNAs/genetics
10.
Healthc (Amst) ; 10(3): 100640, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35841839

ABSTRACT

Two-thirds of health professionals facing the clinical demands of responding to the Covid-19 pandemic experience psychiatric symptoms, including post-traumatic stress, anxiety, substance use, depression, insomnia, and suicide.1,2 Compounding matters, access to mental health services is poor, quality is variable, and stigma is prevalent. COBALT, a digital mental health and wellness platform developed at Penn Medicine, was designed to support health care workers, offering a combination of self-directed resources, virtual group sessions, and individual appointments with a stepped care model of providers, including peers, resilience coaches, psychotherapists, and psychiatrists. In COBALT's first 11 months, the platform saw approximately 10,000 users, 200,000 page views, 1,400 one-on-one appointment bookings, over 1,000 group appointment reservations, and 158 interceptions of employees contemplating self-harm. COBALT reveals the unmet demand for mental health support among health professionals and provides a model for both expanding the supply of and streamlining access to services.


Subject(s)
COVID-19 , Cobalt , Delivery of Health Care , Health Personnel/psychology , Humans , Mental Health , Pandemics , SARS-CoV-2 , Technology , Workforce
11.
Diagnostics (Basel) ; 12(5)2022 May 03.
Article in English | MEDLINE | ID: mdl-35626287

ABSTRACT

We have conducted cervical imaging of uterine and micro-vessel flow velocity waveforms in acute pelvic inflammatory disease (PID) by transvaginal power Doppler ultrasound (TVPDU) in order to explore the associations of sonographic parameters with simple and complex cervicitis. Thirty-eight patients with acute PID (26 with acute simple cervicitis and 12 with complex cervicitis) were enrolled for an assessment of vascular grading of cervix and micro-vessel flow velocity using TVPDU before treatment. Seven parameters, including vascular grading (VG), lowest pulsatility index (PI), resistance index (RI), peak systolic velocity (PS), end diastolic velocity (ED), time average maximum velocity (TAMV), and vascular index (VI = PS/ED), were measured and recorded. Forty-one healthy patients were assessed as the control group. Vascular grading (VG) was significantly higher in the study group than the control group (p < 0.0001). The PI, RI, and VI were significantly lower in the study group than control group (p < 0.0001). No significant associations were observed between seven sonographic parameters and acute simple or/and complex cervicitis. For acute simple cervicitis, a PI cutoff of 1.1 had a sensitivity of 85.4% and a specificity of 92.1% (area under ROC curve [AUC], 93.2%). A RI of 0.6 had a sensitivity of 85.4% and a specificity of 78.9% (AUC, 86.1%). A VI of 2.6 had a sensitivity of 85.4% and a specificity of 78.9% (AUC, 84.9%). Power Doppler angiography of micro-vessel flow velocity waveforms in the cervix could represent a practical method to assist the diagnosis of pelvic inflammatory disease presented as acute cervicitis detected on transvaginal ultrasound before medical or surgical treatment. Cervical PI may be a useful index to detect micro-vessel flow velocity waveforms in acute cervicitis and differentiate acute simple cervicitis from complex cervicitis.

12.
Am J Med Qual ; 37(1): 39-45, 2022.
Article in English | MEDLINE | ID: mdl-34310377

ABSTRACT

Building organizational capacity is critical for hospitals participating in payment models such as bundled payments and accountable care organizations, particularly "co-participant" hospitals with experience in both models. This study used a national survey of American Hospital Association member hospitals with bundled payment experience, with (co-participant hospitals) or without (bundled payment hospitals) accountable care organization experience. Questions examined capacity in 4 domains: performance feedback, postacute care provider utilization, care management, and health information technology. Of 424 hospitals, 38% responded. Both co-participant and bundled payment hospitals reported high capacity for performance feedback and risk stratification and predictive risk assessment using health information technology systems. The hospital groups did not differ in care management capacity, but bundled payment hospitals reported higher postacute care provider utilization capacity. Experience with multiple payment models may prompt hospitals to make different investments or adopt different strategies than hospitals with experience in a single model.


Subject(s)
Accountable Care Organizations , Capacity Building , Hospitals , Humans , Medicare , Reimbursement Mechanisms , United States
13.
Fertil Steril ; 116(1): 181-188, 2021 07.
Article in English | MEDLINE | ID: mdl-33823989

ABSTRACT

OBJECTIVE: To identify predictor microRNAs (miRNAs) from patients with repeated implantation failure (RIF). DESIGN: Systemic analysis of miRNA profiles from the endometrium of patients undergoing in vitro fertilization (IVF). SETTING: University research institute, private IVF center, and molecular testing laboratory. PATIENT(S): Twenty five infertile patients in the discovery cohort and 11 patients in the validation cohort. INTERVENTIONS(S): None. MAIN OUTCOME MEASURE(S): A signature set of miRNA associated with the risk of RIF. RESULT(S): We designed a reproductive disease-related PanelChip to access endometrium miRNA profiles in patients undergoing IVF. Three major miRNA signatures, including hsa-miR-20b-5p, hsa-miR-155-5p, and hsa-miR-718, were identified using infinite combination signature search algorithm analysis from 25 patients in the discovery cohort undergoing IVF. These miRNAs were used as biomarkers in the validation cohort of 11 patients. Finally, the 3-miRNA signature was capable of predicting patients with RIF with an accuracy >90%. CONCLUSION(S): Our findings indicated that specific endometrial miRNAs can be applied as diagnostic biomarkers to predict RIF. Such information will definitely help to increase the success rate of implantation practice.


Subject(s)
Embryo Implantation/genetics , Embryo Transfer , Endometrium/physiopathology , Fertilization in Vitro , Gene Expression Profiling , Infertility/therapy , MicroRNAs/genetics , Transcriptome , Algorithms , Embryo Transfer/adverse effects , Female , Fertilization in Vitro/adverse effects , Humans , Infertility/diagnosis , Infertility/genetics , Infertility/physiopathology , Male , Predictive Value of Tests , Pregnancy , Reproducibility of Results , Retreatment , Treatment Failure
14.
Opt Express ; 27(11): 15495-15504, 2019 May 27.
Article in English | MEDLINE | ID: mdl-31163745

ABSTRACT

We demonstrate a top-illuminated high-speed uni-traveling carrier photodiode (UTC-PD) with a novel design in the p-type absorber, which can effectively shorten the photon absorption depth at telecommunication wavelengths (1.31~1.55 µm) and further enhance the bandwidth-efficiency product of UTC-PD. In our proposed new UTC-PD structure, the p-type In0.53Ga0.47As absorption layer is replaced by the type-II GaAs0.5Sb0.5 (p)/In0.53Ga0.47As (i) hybrid absorber. Due to the narrowing of the bandgap and enhancement of the photo-absorption process at the type-II interface between the GaAs0.5Sb0.5 and In0.53Ga0.47As layers, our device shows an over 16.7% improvement in the responsivity compared with that of UTC-PD with the same thickness of pure In0.53Ga0.47As absorber (0.7 µm) and a zero optical coupling loss. Our demonstrated device with a simple top-illuminated structure offers a large active mesa (25 µm), a wide optical-to-electrical (O-E) bandwidth (33 GHz), a high responsivity (0.7 A/W), and a high saturation current (>5 mA) under 1.31 µm optical wavelength. These promising results suggest that our proposed PD structure can fundamentally overcome the trade-off among bandwidth, efficiency, and device active diameter of high-speed PDs.

16.
Med Care Res Rev ; 76(1): 56-72, 2019 02.
Article in English | MEDLINE | ID: mdl-29148344

ABSTRACT

While financial incentives to providers or patients are increasingly common as a quality improvement strategy, their impact on patient subgroups and health care disparities is unclear. To examine these patterns, we analyzed data from a randomized clinical trial of financial incentives to lower low-density lipoprotein (LDL) cholesterol levels in patients at risk for cardiovascular disease. Patients with higher baseline LDL experienced greater cholesterol reductions in the shared incentive arm (0.23 mg/dL per unit change in baseline LDL, 95% CI [-0.46, -0.00]) but were also less likely to have medication potency increases in the physician incentive arm ( OR = 0.98, 95% CI [0.97, 0.996]). Uninsured patients and those of race other than Black or White were less likely to have potency increases in the shared incentive arm ( OR = 0.15, 95% CI [0.03, 0.70] and OR = 0.09, 95% CI [0.01, 0.93], respectively). These findings suggest some differential response to incentives, particularly in the form of targeted medication changes.


Subject(s)
Cardiovascular Diseases/prevention & control , Quality Improvement , Reimbursement, Incentive/economics , Female , Humans , Male , Middle Aged , Physicians , Randomized Controlled Trials as Topic
17.
J Am Coll Health ; 66(4): 317-323, 2018.
Article in English | MEDLINE | ID: mdl-29447623

ABSTRACT

OBJECTIVE: To assess the impact of a campus community health worker program (HealthPALs) on student influenza vaccination. PARTICIPANTS: Undergraduate students at a northeastern US university (enrollment 6650), influenza seasons 2011-2012 through 2015-2016. METHODS: Study design: Difference-in-differences analysis of student vaccination at campus dormitory influenza clinics during intervention vs. baseline. INTERVENTION: In the first intervention year, HealthPALs conducted in-person peer outreach at several campus dormitory flu clinics. Subsequent years, HealthPALs conducted an enhanced intervention, with the addition of a personalized, dormitory-specific social media campaign appealing to students' community identity. RESULTS: The initial intervention increased vaccinations by 66% (IRR = 1.66, 95%CI 1.39-1.97) at intervention clinics relative to control. The enhanced intervention increased vaccinations by 85% (IRR = 1.85, 95%CI 1.75-1.96). CONCLUSION: Community health workers can be a highly effective, low-cost strategy for increasing influenza vaccination among college students. This model could also be used to address other campus health challenges where student engagement is key.


Subject(s)
Community Health Workers/organization & administration , Influenza Vaccines/administration & dosage , Influenza, Human/prevention & control , Students , Universities/organization & administration , Community Health Workers/economics , Female , Housing , Humans , Male , Student Health Services/organization & administration , Universities/economics , Vaccination Coverage/methods , Vaccination Coverage/statistics & numerical data , Young Adult
18.
Emerg Med J ; 34(6): 398-401, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27852652

ABSTRACT

INTRODUCTION: Maintaining the standard two-handed chest compression is difficult in high-speed ambulances in rural areas. METHODS: A retrospective, video-based, observational study was conducted from June to September 2013 in Nantou, a rural county of central Taiwan, to evaluate the chest compression fraction in an ambulance carriage during the travel from the scene to the hospital. The chest compression fraction was calculated as the chest compression time period divided by the ambulance travelling time period; the one-handed and two-handed chest compression fractions were also calculated. RESULTS: During the 4-month study period, a total of 102 videos that were recorded in an ambulance carriage were reviewed, including 97 cases of manual chest compressions. When there was only one emergency medical technician (EMT) in the carriage, the combined chest compression fraction was 50.6±20.7%; when there were two EMTs, the fraction was 58.3±16.0% and the fraction was 58.3±21.0% in a three-EMT scenario (p=0.221). Moreover, in the carriage, EMTs usually performed one-handed chest compressions. CONCLUSIONS: The chest compression fraction was low for patients with out-of-hospital cardiac arrest in a moving ambulance, irrespective of the number of providers. Reasons for this observation, as well as the effectiveness of the one-handed chest compression require further evaluation.


Subject(s)
Cardiopulmonary Resuscitation/methods , Cardiopulmonary Resuscitation/standards , Emergency Medical Technicians/standards , Out-of-Hospital Cardiac Arrest/therapy , Ambulances , Humans , Retrospective Studies , Taiwan , Time Factors , Workforce
19.
Methods Mol Biol ; 1154: 171-231, 2014.
Article in English | MEDLINE | ID: mdl-24782010

ABSTRACT

Assisted reproductive technologies (ART) encompass fertility treatments, which involve manipulations of both oocyte and sperm in vitro. This chapter provides a brief overview of ART, including indications for treatment, ovarian reserve testing, selection of controlled ovarian hyperstimulation (COH) protocols, laboratory techniques of ART including in vitro fertilization (IVF), and intracytoplasmic sperm injection (ICSI), embryo transfer techniques, and luteal phase support. This chapter also discusses potential complications of ART, namely ovarian hyperstimulation syndrome (OHSS) and multiple gestations, and the perinatal outcomes of ART.


Subject(s)
Embryo Transfer/methods , Fertilization in Vitro/methods , Ovulation Induction/methods , Reproductive Techniques, Assisted , Female , Fertility/genetics , Humans , Molecular Biology/methods , Oocytes/physiology , Pregnancy , Sperm Injections, Intracytoplasmic/methods
20.
Healthc (Amst) ; 1(3-4): 152-3, 2013 Dec.
Article in English | MEDLINE | ID: mdl-26249787
SELECTION OF CITATIONS
SEARCH DETAIL
...