Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
VideoGIE ; 3(11): 361-363, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30402586

ABSTRACT

BACKGROUND AND AIMS: Portal hypertension is a serious adverse event of liver cirrhosis. Recently, we developed a simple novel technique for EUS-guided portal pressure gradient (PPG) measurement (PPGM). Our animal studies showed excellent correlation between EUS-PPGM and interventional radiology-acquired PPGM. In this video we demonstrate the results of the first human pilot study of EUS-PPGM in patients with liver disease. METHODS: EUS-PPGM was performed by experienced endosonographers using a linear echoendoscope, a 25-gauge FNA needle, and a novel compact manometer. The portal vein and hepatic vein (or inferior vena cava) were targeted by use of a transgastric or transduodenal approach. Feasibility was defined as successful PPGM in each patient. Safety was based on adverse events captured in a postprocedural interview. RESULTS: Twenty-eight patients underwent EUS-PPGM with 100% technical success and no adverse events. PPG ranged from 1.5 to 19 mm Hg and had excellent correlation with clinical parameters of portal hypertension, including the presence of varices (P = .0002), PH gastropathy (P = .007), and thrombocytopenia (P = .036). CONCLUSION: This novel technique of EUS-PPGM using a 25-gauge needle and compact manometer is feasible and appears safe. Given the availability of EUS and the simplicity of the manometry setup, EUS-guided PPG may represent a promising breakthrough for procuring indispensable information in the management of patients with liver disease.

2.
3.
ACG Case Rep J ; 4: e2, 2017.
Article in English | MEDLINE | ID: mdl-28138446

ABSTRACT

Biliary leaks are uncommon but morbid complications of pancreaticoduodenectomies, which have historically been managed with percutaneous drainage, reoperation, or a combination of both. We report a de novo percutaneous-endoscopic hepaticojejunostomy from an anomalous right hepatic duct injured during pancreaticoduodenectomy to the afferent bowel limb. The percutaneous-endoscopic hepaticojejunostomy was stented to allow for tract formation with successful stent removal after 5.5 months. One year after the creation of the percutaneous-endoscopic hepaticojejunostomy, the patient remains clinically well without evidence of biliary leak or obstruction.

4.
Gastrointest Endosc ; 85(5): 996-1001, 2017 May.
Article in English | MEDLINE | ID: mdl-27693644

ABSTRACT

BACKGROUND AND AIMS: Portal hypertension (PH) is a serious adverse event of liver cirrhosis. The hepatic venous pressure gradient or portal pressure gradient (PPG) accurately reflects the degree of PH and is the single best prognostic indicator in liver disease. This is usually obtained by interventional radiology (IR), although it is not routinely performed. Recently, we developed a simple novel technique for EUS-guided PPG measurement (PPGM). Our animal studies showed excellent correlation between EUS-PPGM and IR-PPGM. We present the first human pilot study of EUS-PPGM in patients with liver disease. METHODS: EUS-PPGM was performed by experienced endosonographers using a linear echoendoscope, a 25-gauge fine-needle aspiration needle, and a novel compact manometer. The portal vein and hepatic vein (or inferior vena cava) were targeted using a transgastric-transduodenal approach. Clinical parameters of PH were evaluated in each patient. Feasibility was defined as successful PPGM in each patient. Safety was based on adverse events captured in a postprocedural interview. RESULTS: Twenty-eight patients underwent EUS-PPGM with 100% technical success and no adverse events. PPG ranged from 1.5 to 19 mm Hg and had excellent correlation with clinical parameters of portal hypertension including the presence of varices (P = .0002), PH gastropathy (P = .007), and thrombocytopenia (P = .036). PPG was increased in patients with high clinical evidence of cirrhosis (P = .005). CONCLUSION: This novel technique of EUS-PPGM using a 25-gauge needle and compact manometer is feasible and appears safe. Given the availability of EUS and the simplicity of the manometry setup, EUS-guided PPG may represent a promising breakthrough for procuring indispensable information in the management of patients with liver disease.


Subject(s)
Blood Pressure Determination/methods , Endosonography/methods , Hypertension, Portal/diagnosis , Portal Pressure , Adult , Aged , Aged, 80 and over , Esophageal and Gastric Varices/etiology , Feasibility Studies , Female , Hepatic Veins , Humans , Hypertension, Portal/complications , Liver Cirrhosis/complications , Male , Manometry/instrumentation , Middle Aged , Needles , Pilot Projects , Portal Vein , Stomach Diseases/etiology , Thrombocytopenia/etiology , Vena Cava, Inferior
6.
Gastrointest Endosc ; 84(2): 358-62, 2016 Aug.
Article in English | MEDLINE | ID: mdl-26945557

ABSTRACT

BACKGROUND AND AIMS: Portal hypertension (PH) is a serious adverse event of liver cirrhosis. The hepatic venous pressure gradient (HVPG) accurately reflects the degree of PH and is the single best prognostic factor in liver disease. Currently, portal pressure gradient (PPG) measurement is performed at interventional radiology (IR) with a standard transjugular approach requiring radiation and intravenous contrast. The aim of this study was to develop a novel EUS-guided system using a 25G FNA needle and compact manometer to directly measure PPG and to evaluate its performance and clinical feasibility. METHODS: Experiments were performed in 3 swine that were under general anesthesia. Manometry was performed in venous (baseline and PH) and arterial (aorta) systems. The PH model was created by rapid Dextran-40 infusion peripherally. Under EUS guidance a 25G FNA needle with attached manometer was used to puncture (transgastric-transhepatic approach) and measure pressures in the portal vein, right hepatic vein (RHV), inferior vena cava (IVC), and aorta. With the IR approach, RHV (free and wedged), IVC, and aorta pressure were measured with an occlusion balloon. Pressure correlation was divided into 3 groups; low pressure (baseline), medium pressure (noncirrhotic portal hypertensive model), and high pressure (arterial). Correlation between the 2 methods of measurement was charted in scatter plots, and the Pearson's correlation coefficient (R) was calculated. RESULTS: EUS identification, access, and manometry was successful in all targeted vessels. There was excellent correlation (R, .985-.99) between EUS and IR methods in all pressure ranges. No adverse event occurred. CONCLUSIONS: This novel technique of EUS-PPG measurement using a 25G needle and novel manometer was feasible and demonstrated excellent correlation with the standard transjugular method throughout low, medium, and high pressure ranges.


Subject(s)
Aorta , Blood Pressure Determination/instrumentation , Hepatic Veins , Jugular Veins , Manometry/instrumentation , Portal Pressure , Vena Cava, Inferior , Animals , Arterial Pressure , Blood Pressure Determination/methods , Endosonography , Feasibility Studies , Manometry/methods , Needles , Swine , Ultrasonography, Interventional
SELECTION OF CITATIONS
SEARCH DETAIL
...