Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE Trans Med Imaging ; PP2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38607705

ABSTRACT

With the widespread interest and uptake of super-resolution ultrasound (SRUS) through localization and tracking of microbubbles, also known as ultrasound localization microscopy (ULM), many localization and tracking algorithms have been developed. ULM can image many centimeters into tissue in-vivo and track microvascular flow non-invasively with sub-diffraction resolution. In a significant community effort, we organized a challenge, Ultrasound Localization and TRacking Algorithms for Super-Resolution (ULTRA-SR). The aims of this paper are threefold: to describe the challenge organization, data generation, and winning algorithms; to present the metrics and methods for evaluating challenge entrants; and to report results and findings of the evaluation. Realistic ultrasound datasets containing microvascular flow for different clinical ultrasound frequencies were simulated, using vascular flow physics, acoustic field simulation and nonlinear bubble dynamics simulation. Based on these datasets, 38 submissions from 24 research groups were evaluated against ground truth using an evaluation framework with six metrics, three for localization and three for tracking. In-vivo mouse brain and human lymph node data were also provided, and performance assessed by an expert panel. Winning algorithms are described and discussed. The publicly available data with ground truth and the defined metrics for both localization and tracking present a valuable resource for researchers to benchmark algorithms and software, identify optimized methods/software for their data, and provide insight into the current limits of the field. In conclusion, Ultra-SR challenge has provided benchmarking data and tools as well as direct comparison and insights for a number of the state-of-the art localization and tracking algorithms.

2.
Sci Rep ; 8(1): 14640, 2018 10 02.
Article in English | MEDLINE | ID: mdl-30279545

ABSTRACT

Diffusion tensor tractography (DTT) enables visualization of fiber trajectories in soft tissue using magnetic resonance imaging. DTT exploits the anisotropic nature of water diffusion in fibrous structures to identify diffusion pathways by generating streamlines based on the principal diffusion vector. Anomalies in these pathways can be linked to neural deficits. In a different field, contrast-enhanced ultrasound is used to assess anomalies in blood flow with the aim of locating cancer-induced angiogenesis. Like water diffusion, blood flow and transport of contrast agents also shows a principal direction; however, this is now determined by the local vasculature. Here we show how the tractographic techniques developed for magnetic resonance imaging DTT can be translated to contrast-enhanced ultrasound, by first estimating contrast flow velocity fields from contrast-enhanced ultrasound acquisitions, and then applying tractography. We performed 4D in-vivo contrast-enhanced ultrasound of three human prostates, proving the feasibility of the proposed approach with clinically acquired datasets. By comparing the results to histopathology after prostate resection, we observed qualitative agreement between the contrast flow tracts and typical markers of cancer angiogenic microvasculature: higher densities and tortuous geometries in tumor areas. The method can be used in-vivo using a standard contrast-enhanced ultrasound protocol, opening up new possibilities in the area of vascular characterization for cancer diagnostics.


Subject(s)
Diffusion Tensor Imaging/methods , Image Enhancement/methods , Imaging, Three-Dimensional/methods , Neovascularization, Pathologic/diagnostic imaging , Prostate/blood supply , Prostate/diagnostic imaging , Prostatic Neoplasms/blood supply , Prostatic Neoplasms/diagnostic imaging , Ultrasonography/methods , Contrast Media , Humans , Male
3.
Am J Surg ; 202(5): 605-11, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21824594

ABSTRACT

BACKGROUND: This study was designed to compare the accuracy of endoscopic ultrasound (EUS) with double contrast-enhanced ultrasound (DCUS) in the staging of gastric malignancies. DCUS is a transabdominal ultrasound technique using both intravenous and intraluminal contrast to enhance sonographic visualization. METHODS: This retrospective study included 162 patients with biopsy-proven gastric cancer who underwent DCUS and EUS preoperatively with the ultrasound results compared with the pathologic findings of the resected specimens. RESULTS: The overall accuracy of DCUS and EUS for tumor (T) staging was 77.2% and 74.7%, respectively. Comparison of ultrasound techniques for T staging revealed that DCUS was superior to EUS only for a tumor depth of T3 (chi-square, P = .025). Lymph nodes were staged correctly with DCUS and EUS in 78.4% and 57.4% of cases, respectively (chi-square, P = .001). CONCLUSIONS: DCUS offers a noninvasive approach for the staging of gastric cancer. DCUS was comparable to EUS in tumor depth evaluation but offered an advantage in lymph node detection.


Subject(s)
Endosonography , Neoplasm Staging/methods , Preoperative Care , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Contrast Media/administration & dosage , Female , Gastrectomy , Humans , Lymph Nodes/pathology , Male , Middle Aged , Retrospective Studies , Stomach Neoplasms/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...