Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Small ; 20(14): e2309014, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37972262

ABSTRACT

Developing single-atomic catalysts with superior selectivity and outstanding stability for CO2 electroreduction is desperately required but still challenging. Herein, confinement strategy and three-dimensional (3D) nanoporous structure design strategy are combined to construct unsaturated single Ni sites (Ni-N3) stabilized by pyridinic N-rich interconnected carbon nanosheets. The confinement agent chitosan and its strong interaction with g-C3N4 nanosheet are effective for dispersing Ni and restraining their agglomeration during pyrolysis, resulting in ultrastable Ni single-atom catalyst. Due to the confinement effect and structure advantage, such designed catalyst exhibits a nearly 100% selectivity and remarkable stability for CO2 electroreduction to CO, exceeding most reported state-of-the-art catalysts. Specifically, the CO Faradaic efficiency (FECO) maintains above 90% over a broad potential range (-0.55 to -0.95 V vs. RHE) and reaches a maximum value of 99.6% at a relatively low potential of -0.67 V. More importantly, the FECO is kept above 95% within a long-term 100 h electrolyzing. Density functional theory (DFT) calculations explain the high selectivity for CO generation is due to the high energy barrier required for hydrogen evolution on the unsaturated Ni-N3. This work provides a new designing strategy for the construction of ultrastable and highly selective single-atom catalysts for efficient CO2 conversion.

2.
Int J Clin Exp Med ; 8(9): 16077-82, 2015.
Article in English | MEDLINE | ID: mdl-26629115

ABSTRACT

The aim of this study was to investigate the clinical application effects of a novel computer-aided detection (CAD) system based on three-dimensional computed tomography (CT) images on pulmonary nodule. 98 cases with pulmonary nodule (PN) in our hospital from Jun, 2009 to Jun, 2013 were analysed in this study. All cases underwent PN detection both by the simple spiral CT scan and by the computer-aided system based on 3D CT images, respectively. Postoperative pathological results were considered as the "gold standard", for both two checking methods, the diagnostic accuracies for determining benign and malignant PN were calculated. Under simple spiral CT scan method, 63 cases is malignant, including 50 true positive cases and 13 false positive cases from the "gold standard"; 35 cases is benign, 16 true negative case and 19 false negative cases, the Sensitivity 1 (Se1)=0.725, Specificity1 (Sp1)=0.448, Agreement rate1 (Kappa 1)=0.673, J1 (Youden's index 1)=0.173, LR(+)1=1.616, LR(-)1=0.499. Kappa 1=0.673 between the 0.4 and 0.75, has a moderate consistency. Underwent computer-aided detection (CAD) based on 3D CT method, 67cases is malignant, including 62 true positive cases and 7 false positive cases; 31 cases is benign, 24 true negative case and 7 false negative cases, Sensitivity 2 (Se2)=0.899, Specificity2 (Sp2)=0.828, Agreement rate (Kappa 2)=0.877, J2 (Youden's index 2)=0.727, LR(+)2=5.212, LR(-)2=0.123. Kappa 2=0.877 >0.75, has a good consistency. Computer-aided PN detecting system based on 3D CT images has better clinical application value, and can help doctor carry out early diagnosis of lung disease (such as cancer, etc.) through CT images.

SELECTION OF CITATIONS
SEARCH DETAIL
...