Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Front Cardiovasc Med ; 11: 1388313, 2024.
Article in English | MEDLINE | ID: mdl-38957328

ABSTRACT

Background: Hypertension is the most significant global risk factor for mortality and morbidity, making standardized blood pressure measurement crucial. Objectives: To investigate whether the location of blood pressure monitors and the positioning of cuffs yield differing results in blood pressure measurements. Methods: Patients admitted to the Affiliated Hospital of Jiujiang College between 1 January 2022 and 30 June 2023 were enrolled in this study and randomly allocated into four groups. These groups were defined based on the positioning of monitoring equipment as follows: varied placements of cuffs on automatic blood pressure monitors, different heights for mercury column blood pressure monitors, varied heights for automatic blood pressure monitors, and different orientations for the cuff airbag tubes on electrocardiogram monitors. Blood pressure was measured and recorded for each group, followed by an analysis of the variations in readings across the different setups. Results: In the first cohort of 763 individuals, mean systolic blood pressure measured at the standard upper arm site was 128.8 ± 10.5 mmHg, compared to 125.3 ± 10.4 mmHg at the elbow fossa. The corresponding diastolic pressures were 79.2 ± 10.7 and 75.0 ± 10.6 mmHg, respectively. The difference in systolic pressure between these positions was significant at 3.48 ± 3.22 mmHg (t1 = 29.91, p1 < 0.001) and for diastolic pressure at 4.23 ± 1.31 mmHg (t2 = 88.98, p2 < 0.001). For the subsequent groups, involving 253, 312, and 225 individuals, respectively, blood pressure measurements were analyzed and compared across different methods within each group. All p-values exceeded 0.05, indicating no statistically significant differences. Conclusions: Blood pressure values measured at the elbow fossa position using an upper arm-type automatic sphygmomanometer were found to be lower than those measured at the upper arm position, with a difference of 3.48 mmHg for systolic and 4.23 mmHg for diastolic pressures. It is therefore essential to position the cuff correctly, specifically 2-3 cm above the elbow fossa, when utilizing an upper arm-type automatic sphygmomanometer for blood pressure monitoring. Conversely, the placement of the mercury column sphygmomanometer and the automated sphygmomanometer at varying heights had no significant effect on blood pressure readings. Similarly, the orientation of the electrocardiogram's cuffed balloon tube, whether facing upward or downward, did not influence blood pressure measurement outcomes.

2.
World J Clin Cases ; 10(33): 12352-12357, 2022 Nov 26.
Article in English | MEDLINE | ID: mdl-36483839

ABSTRACT

BACKGROUND: Currently, the implantation of permanent cardiac pacemakers entails mostly subclavian vein puncture, which is relatively simpler and easier to master. However, due to individual differences, some patients carry a narrow space between the clavicle and the first rib. If the range of activity of the upper limb is increased, the friction between the electrode wire and the bone gap leads to the breakage of the electrode wire, which is manifested by poor pacemaker perception and pacing. CASE SUMMARY: A 68-year-old woman underwent permanent pacemaker implantation in our hospital because of third-degree atrioventricular block 6 years ago. At that time, the patient was recommended to have a dual-chamber permanent pacemaker implantation, and finally chose a single-chamber permanent pacemaker because she could not afford the cost. The patient has repeatedly lost consciousness for no obvious reason in the past 3 d, and went to our hospital for treatment. The chest X-ray showed that the pacemaker electrode was broken. After the patient was given a pacemaker electrode replacement, the patient did not continue to lose consciousness. CONCLUSION: Because the electrodes implanted in the subclavian approach are close to the clavicle and the first rib, the pacemaker electrodes may wear out. If the patient loses consciousness again after the pacemaker is implanted, we should consider whether there is a pacemaker. The possibility of electrode breakage, and timely help the patient to replace the new pacemaker electrodes.

3.
Mol Med Rep ; 20(1): 350-358, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31115545

ABSTRACT

Endoplasmic reticulum (ER) stress and autophagy are involved in myocardial ischemia­reperfusion (I/R) injury; however, their roles in this type of injury remain unclear. The present study investigated the roles of ER stress and autophagy, and their underlying mechanisms, in H9c2 cells during hypoxia/reoxygenation (H/R) injury. Cell viability was detected by CCK­8 assay. The autophagy flux was monitored with mCherry­GFP­LC3­adenovirus transfection. The expression levels of autophagy­related proteins and ER stress­related proteins were measured by western blotting. Apoptosis was detected by flow cytometry and western blotting. The results indicated that autophagy was induced, ER stress was activated and apoptosis was promoted in H9c2 cells during H/R injury. The inhibition of ER stress by 4­phenylbutyrate or C/EBP homologous protein (CHOP)­targeting small interfering RNA (siRNA) decreased autophagy and ameliorated cell apoptosis during H/R injury. Activation of autophagy by rapamycin attenuated ER stress and ameliorated cell apoptosis. Inhibition of autophagy by 3­methyladenine or Beclin1­targeting siRNA aggravated ER stress and exacerbated cell apoptosis, and activation of ER stress by thapsigargin decreased autophagy and induced cell apoptosis. Collectively, the findings of the present study demonstrated that H/R induced apoptosis and autophagy via ER stress in H9c2 cells, and that CHOP may serve an important role in ER stress­induced autophagy and apoptosis. Autophagy, as an adaptive response, was activated by ER stress and alleviated ER stress­induced cell apoptosis during H/R injury.


Subject(s)
Autophagy/genetics , Endoplasmic Reticulum Stress/genetics , Myocardial Reperfusion Injury/genetics , Myocytes, Cardiac/drug effects , Animals , Apoptosis/drug effects , Autophagy/drug effects , Autophagy-Related Proteins/genetics , Beclin-1/genetics , Cell Hypoxia/genetics , Cell Line , Gene Expression Regulation/genetics , Humans , Myocardial Reperfusion Injury/pathology , Myocardial Reperfusion Injury/therapy , Myocytes, Cardiac/metabolism , Myocytes, Cardiac/pathology , Phenylbutyrates/pharmacology , RNA, Small Interfering/genetics , Rats , Signal Transduction/drug effects , Transcription Factor CHOP/genetics
4.
Naunyn Schmiedebergs Arch Pharmacol ; 392(6): 715-722, 2019 06.
Article in English | MEDLINE | ID: mdl-30762075

ABSTRACT

Endoplasmic reticulum (ER) stress-induced apoptosis is a major cause of myocardial ischemia/reperfusion (I/R) injury. Emerging evidence indicates that glucagon-like peptide-1 (GLP-1) has potential cardioprotective effects. However, the precise mechanisms underlying the involvement of GLP-1 in I/R injury remain largely unknown. In the present study, we aimed to determine whether GLP-1 attenuates hypoxia/reoxygenation (H/R) injury in cardiomyocytes and to further elucidate the underlying signaling pathway. The results indicate that GLP-1 reversed the increased apoptotic ratio, the increased lactate dehydrogenase (LDH) levels, the reduced cell viability, the increased Caspase-3 activity, and the increased Bax/Bcl-2 ratio caused by H/R. Importantly, GLP-1 significantly decreased the expression of H/R-induced ER stress proteins (GRP78, CHOP) and Caspase-12. In addition, we found that GLP-1 increased the expression of p-Akt in H9c2 cells with H/R injuries, and that the protective action of GLP-1 against H/R-induced injury was blocked by the GLP-1 receptor (GLP-1R) inhibitor Exendin9-39 and the PI3K inhibitor LY294002. Exendin9-39 and LY294002 also blocked the downregulation of ER stress protein expression by GLP-1, after H/R injury. Therefore, we have shown that GLP-1 exerts its cardioprotective effects by alleviating ER stress-induced apoptosis due to H/R injury and that these effects are most likely associated with the activation of GLP-1R/PI3K/Akt signaling pathway.


Subject(s)
Apoptosis/drug effects , Endoplasmic Reticulum Stress/drug effects , Glucagon-Like Peptide 1/pharmacology , Glucagon-Like Peptide-1 Receptor/physiology , Myocardial Reperfusion Injury/prevention & control , Myocytes, Cardiac/drug effects , Phosphatidylinositol 3-Kinases/physiology , Proto-Oncogene Proteins c-akt/physiology , Animals , Cells, Cultured , Endoplasmic Reticulum Stress/physiology , Myocytes, Cardiac/physiology , Rats , Signal Transduction/drug effects , Signal Transduction/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...