Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 24(8)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38676145

ABSTRACT

The state detection of power cables is very important to ensure the reliability of the power supply. Traditional sensors are mostly based on electric field detection. The operation is complex, and its efficiency needs to be improved. This paper optimizes the design and development of the magnetic field detection sensor for AC power cables. First, through the establishment of the magnetic field sensor model, it is determined that permalloy is the material of the magnetic core, the optimal aspect ratio of the magnetic core is 20, and the ratio of coil length to core length is 0.3. Second, the coil-simulation model is established, and it is determined that the optimal number of turns of the coil is 11,000 turns, the diameter of the enameled copper wire is 0.08 mm, and the equivalent magnetic field noise of the sensor is 0.06 pT. Finally, the amplifying circuit based on negative magnetic flux feedback is designed, the sensor is assembled, and the experimental circuit is built for the sensitivity test. The results show that the sensitivity of the magnetic field sensor is 327.6 mV/µT. The sensor designed in this paper has the advantages of small size, high sensitivity, ease of carry, and high reliability.

2.
Polymers (Basel) ; 14(18)2022 Sep 09.
Article in English | MEDLINE | ID: mdl-36145930

ABSTRACT

Electrical treeing is one of the main causes of crosslinked polyethylene (XLPE) cable failure. The current methods for locating electrical trees are mainly based on the partial discharge (PD) signal. However, PD signals are easily attenuated in the long cable and the PD test voltage may cause damage to the insulation. This work proposes an improved broadband impedance spectrum (BIS) method to locate electrical trees in XLPE cable. A mathematical model of a long cable containing local electrical tree degradation is established. The Gaussian signal is chosen as the simulated incident signal to reduce the spectral leakage. The location spectrum is obtained by multiplying the frequency domain function of the single-ended reflection coefficient and the Gaussian pulse. It has been found that the location spectrum of the local capacitance change can be characterized as a typical double-peak waveform and the spectrum of the local conductance change can be regarded as a typical single-peak waveform. Electrical tree experiments at different temperatures were carried out to initiate different types of electrical trees. A vector network analyzer (VNA) was used to test the high frequency capacitance characteristics in the treeing process. The location spectra of the 20 m long cable containing different types of electrical trees was calculated by the improved location algorithm. The results show that the location error of local electrical tree degradation is less than 3%. The capacitance of the sliced sample decreases with treeing time. The effect of the bush-pine tree on capacitance parameters is greater than that of the branch-pine tree. A typical double-peak is found in the bush-pine tree location spectrum and a single-peak is found in the branch-pine tree spectrum.

SELECTION OF CITATIONS
SEARCH DETAIL
...