Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 294
Filter
1.
Res Sq ; 2024 May 02.
Article in English | MEDLINE | ID: mdl-38746233

ABSTRACT

Background: There is growing interest in the development of next-generation probiotics to prevent or treat metabolic syndrome. Previous studies suggested that Anaerobutyricum soehngenii may represent a promising probiotic candidate. A recent human study showed that while A. soehngenii supplementation is well tolerated and safe, it resulted in variable responses among individuals with a subset of the subjects significantly benefiting from the treatment. We hypothesized that gut microbiome variation is linked to the heterogeneous responses to A. soehngenii treatment observed in humans. Results: We colonized germ-free mice with fecal microbiota from human subjects that responded to A. soehngenii treatment (R65 and R55) and non-responder subjects (N96 and N40). Colonized mice were fed a high-fat diet (45% kcal from fat) to induce insulin resistance, and orally treated with either live A. soehngenii culture or heat-killed culture. We found that R65-colonized mice received a benefit in glycemic control with live A. soehngenii treatment while mice colonized with microbiota from the other donors did not. The glucose homeostasis improvements observed in R65-colonized mice were positively correlated with levels of cecal propionate, an association that was reversed in N40-colonized mice. To test whether the microbiome modulates the effects of propionate, R65- or N40-colonized mice were treated with tripropionin (TP, glycerol tripropionate), a pro-drug of propionate, or glycerol (control). TP supplementation showed a similar response pattern as that observed in live A. soehngenii treatment, suggesting that propionate may mediate the effects of A. soehngenii. We also found that TP supplementation to conventional mice reduces adiposity, improves glycemic control, and reduces plasma insulin compared to control animals supplemented with glycerol. Conclusions: These findings highlight the importance of the microbiome on glycemic control and underscore the need to better understand personal microbiome-by-therapeutic interactions to develop more effective treatment strategies.

2.
Clin Chem ; 70(4): 669-679, 2024 04 03.
Article in English | MEDLINE | ID: mdl-38385453

ABSTRACT

BACKGROUND: The harmonization status of most tumor markers (TMs) is unknown. We report a feasibility study performed to determine whether external quality assessment (EQA) programs can be used to obtain insights into the current harmonization status of the tumor markers α-fetoprotein (AFP), prostate specific antigen (PSA), carcinoembryonic antigen (CEA), cancer antigen (CA)125, CA15-3 and CA19-9. METHODS: EQA sample results provided by 6 EQA providers (INSTAND [Germany], Korean Association of External Quality Assessment Service [KEQAS, South Korea], National Center for Clinical Laboratories [NCCL, China], United Kingdom National External Quality Assessment Service [UK NEQAS, United Kingdom], Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek [SKML, the Netherlands], and the Royal College of Pathologists of Australasia Quality Assurance Programs [RCPAQAP, Australia]) between 2020 and 2021 were used. The consensus means, calculated from the measurement procedures present in all EQA programs (Abbott Alinity, Beckman Coulter DxI, Roche Cobas, and Siemens Atellica), was used as reference values. Per measurement procedure, the relative difference between consensus mean for each EQA sample and the mean of all patient-pool-based EQA samples were calculated and compared to minimum, desirable, and optimal allowable bias criteria based on biological variation. RESULTS: Between 19040 (CA15-3) and 25398 (PSA) individual results and 56 (PSA) to 76 (AFP) unique EQA samples were included in the final analysis. The mean differences with the consensus mean of patient-pool-based EQA samples for all measurement procedures were within the optimum bias criterion for AFP, the desirable bias for PSA, and the minimum bias criterion for CEA. However, CEA results <8 µg/L exceeded the minimum bias criterion. For CA125, CA15-3, and CA19-9, the harmonization status was outside the minimum bias criterion, with systematic differences identified. CONCLUSIONS: This study provides relevant information about the current harmonization status of 6 tumor markers. A pilot harmonization investigation for CEA, CA125, CA15-3, and CA19-9 would be desirable.


Subject(s)
Biomarkers, Tumor , Carcinoembryonic Antigen , Male , Humans , alpha-Fetoproteins/analysis , Prostate-Specific Antigen , CA-19-9 Antigen , Feasibility Studies , Mucin-1 , CA-125 Antigen
3.
Clin Chem Lab Med ; 62(5): 824-829, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38295422

ABSTRACT

Thyroid-stimulating hormone (TSH) is an important clinical marker in the diagnosis and management of thyroid disease. TSH measurements are reported in milli-International Units per Litre (mIU/L), traceable to a World Health Organisation (WHO) reference material. There is a wide variety of commercial immunoassays for TSH measurements available, which have historically been poorly harmonised due to a lack of commutability of the WHO reference materials with patient samples. This led to the recent development of a serum-based reference panel for TSH, traceable to the WHO reference material, available via the International Federation for Clinical Chemistry and Laboratory Medicine (IFCC), aimed at harmonisation of TSH immunoassays. This report describes recent developments in the TSH reference system, including establishment of the 4th WHO International Standard for TSH, and aims to clarify the relationship between the available reference materials and their intended uses. This 4th WHO IS is widely available and defines the unit of TSH activity, therefore its continued existence is of paramount importance, however it continues to show a lack of commutability with patient in many TSH immunoassays. This makes the C-STFT TSH panel, albeit available in restricted numbers, a critical resource to ensure better TSH assay harmonisation.


Subject(s)
Thyroid Diseases , Thyrotropin , Humans , Reference Standards , Chemistry, Clinical , Immunoassay , Reference Values
4.
CJC Pediatr Congenit Heart Dis ; 2(3): 124-133, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37969355

ABSTRACT

Background: Anomalous aortic origin of a right coronary artery (AAORCA) with an interarterial course merits further evaluation; however, robust risk assessment strategies for myocardial ischemia and sudden cardiac death are currently lacking. The aim of this study is to explore the potential role of fractional flow reserve (FFR), instantaneous wave-free ratio (iFR), and intravascular ultrasound (IVUS) in patients with AAORCA. Methods: Consecutive adult patients with AAORCA with an interarterial course were included. Computed tomography angiography, noninvasive ischemia detection, and FFR, iFR, and IVUS were performed at baseline and during adrenaline-induced stress. External compression was evaluated with IVUS. Results: Eight patients (63% female, mean age: 53 ± 9.5 years) were included. Five patients (63%) were symptomatic, and computed tomography angiography revealed high-risk anatomy of the AAORCA in all patients. Only in 1 (12.5%) patient FFR and iFR were positive; however, this was attributed at large to concomitant diffuse atherosclerosis. In 2 of 8 (25%), IVUS revealed external compression; however, the ostial coronary surface area remained unchanged. In all patients, a conservative treatment strategy was pursued. During a mean follow-up of 29.3 months (standard deviation ±2.6 months), symptoms spontaneously disappeared in 4 of 5 (80%) and no adverse cardiac events occurred in any of the patients. Conclusions: Despite the presence of high-risk anatomy in all patients, none had proven ischemia prompting a conservative treatment strategy. No adverse cardiac events occurred during follow-up, and in the majority of patients, symptoms spontaneously disappeared. Therefore, FFR, iFR, and IVUS with pharmacologic stress merit further investigation and might contribute to ischemia-based risk stratification and management strategies in adult patients with AAORCA.


Contexte: L'anomalie de naissance de l'artère coronaire droite à partir de l'aorte (AAORCA, anomalous aortic origin of a right coronary artery) combinée à un trajet interartériel mérite un examen plus approfondi. Cependant, on observe à l'heure actuelle des lacunes en ce qui a trait à l'emploi de stratégies fiables d'évaluation du risque d'ischémie myocardique et de mort subite d'origine cardiaque. L'objectif de cette étude est d'examiner le rôle potentiel de la mesure de la réserve coronarienne (MRC), de l'évaluation du rapport instantané sans onde (iFR, instantaneous wave-free ratio) et de l'échographie intravasculaire chez des patients présentant une AAORCA. Méthodologie: Des cas de patients adultes consécutifs présentant une AAORCA combinée à un trajet interartériel ont été inclus à l'étude. Une angiographie par tomodensitométrie (TDM), une détection non invasive de la présence d'une ischémie, la MRC, l'évaluation de l'iFR et l'échographie intravasculaire ont été effectuées au début de l'étude ainsi que lors d'un stress induit par l'adrénaline. La compression externe a également été évaluée au moyen d'une échographie intravasculaire. Résultats: Huit patients (63 % de sexe féminin; âge moyen de 53 ans ± 9,5 ans) ont participé à l'étude. Cinq patients (63 %) présentaient des symptômes, et l'angiographie par TDM a révélé une AAORCA à risque élevé chez tous les patients. Les résultats de la MRC et de l'évaluation de l'iFR étaient positifs chez seulement un patient (12,5 %), ce qui est attribuable en majeure partie à une athérosclérose diffuse concomitante. Chez deux patients (25 %), l'échographie intravasculaire a montré une compression externe de l'artère coronaire droite même si l'aire de l'ostium de l'artère n'avait pas changé. Une stratégie thérapeutique prudente a été employée pour tous les patients. Pendant la période de suivi qui a duré en moyenne 29,3 mois (écart-type : ± 2,6 mois), les symptômes se sont résorbés de manière spontanée chez quatre des cinq patients (80 %), et aucun événement cardiaque indésirable n'est survenu. Conclusion: Malgré une anatomie à risque élevé chez tous les patients, aucun d'entre eux ne présentait une ischémie connue, ce qui justifiait une stratégie thérapeutique prudente. Aucun événement cardiaque indésirable n'est survenu durant la période de suivi, et les symptômes se sont résorbés de manière spontanée chez la majorité des patients. À la lumière de ces renseignements, la MRC, l'évaluation de l'iFR et l'échographie intravasculaire lors d'un stress pharmacologique devraient faire l'objet d'autres études et pourraient éventuellement être utiles dans la stratification du risque d'ischémie et dans le choix des stratégies de prise en charge des patients adultes présentant une AAORCA.

5.
Front Cardiovasc Med ; 10: 1093201, 2023.
Article in English | MEDLINE | ID: mdl-37435053

ABSTRACT

Aims: Given the compelling evidence on the effectiveness of sodium-glucose cotransporter 2 inhibitors (SGLT2i) in the conventional heart failure population, SGLT2i deserve exploration in systemic right ventricular (sRV) failure. The initial experience with dapagliflozin in sRV failure patients is described, with a focus on tolerability and short-term effects on clinical outcomes. Methods and results: Ten patients (70% female, median age 50 years [46.5-52]) with symptomatic sRV failure who received dapagliflozin 10 mg per day on top of optimal medical therapy between 04-2021 and 01-2023 were included. Within 4 weeks, no significant changes in blood pressure, electrolytes, or serum glucose occurred. Creatinine and estimated glomerular filtration rate (eGFR) showed a slight decline (88 ± 17 to 97 ± 23 µmol/L, p = 0.036, and 72 ± 14 vs. 66 ± 16 ml/min/1.73m2, p = 0.020, respectively). At 6 months follow-up (n = 8), median NT-proBNP decreased significantly from 736.6 [589.3-1193.3] to 531.6 [400.8-1018] ng/L (p = 0.012). Creatinine and eGFR recovered to baseline levels. There were no significant changes in echocardiographic systolic sRV or left ventricular function. New York Heart Association class improved significantly in 4 out of 8 patients (p = 0.046), who also showed an improvement in the 6-minute walk test or bicycle exercise test performance. One female patient developed an uncomplicated urinary tract infection. No patients discontinued treatment. Conclusion: Dapagliflozin was well-tolerated in this small cohort of sRV failure patients. While the early results on the reduction of NT-proBNP and clinical outcome parameters are encouraging, large-scale prospective studies are warranted to thoroughly evaluate the effects of SGLT2i in the growing sRV failure population.

6.
J Mass Spectrom Adv Clin Lab ; 29: 9-15, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37449264

ABSTRACT

Background: Free thyroxine (FT4) measurement is one of the most requested tests in patient care for diagnosing and treating thyroid-related illnesses. Equilibrium dialysis (ED) is considered the "gold standard" for FT4 measurement; however, several factors have a profound effect on the reliability of FT4 assays and require special consideration. Methods: In the current study, we focused on evaluating critical factors that could contribute to reporting errors, such as adsorption of thyroxine (T4) to labware surfaces, stability of serum samples, stock solutions, and calibrator storage conditions, as well as the solvents used to prepare T4 solutions. Results: The adsorption of T4 in ethanolic solutions and dialysates to labware surfaces can be reduced with the careful selection of pipette tips, test tubes, and 96-well plates. Adding pH modifiers to neat T4 solutions can improve its stability. FT4 in serum samples remains stable after exposure to four freeze-thaw cycles, 5 °C for 18-20 h, or -70 °C for a minimum of three years. Conclusion: The presented study has demonstrated that the loss of analyte due to pre-analytical and analytical factors during operation of the FT4 reference measurement procedure (RMP) can be minimized by careful selection of all labware for sample preparation. It was found that the accuracy and imprecision of FT4 assays can be influenced by different types of dialysis devices, but acceptable alternatives to ED membranes were identified. This study demonstrates approaches to establish a FT4 method that is independent from specific suppliers and addresses critical pre-analytical and analytical factors important for FT4 measurements.

7.
Heart ; 109(20): 1525-1532, 2023 Sep 28.
Article in English | MEDLINE | ID: mdl-37169551

ABSTRACT

OBJECTIVE: Patients with a systemic right ventricle (sRV) in the context of transposition of the great arteries (TGA) after atrial switch or congenitally corrected TGA (ccTGA) are prone to sRV dysfunction. Pharmacological options for sRV failure remain poorly defined. This study aims to investigate the tolerability and effects of sacubitril/valsartan on sRV failure in adult patients with sRV. METHODS: In this two-centre, prospective cohort study, all consecutive adult patients with symptomatic heart failure and at least moderately reduced sRV systolic function were initiated on sacubitril/valsartan and underwent structured follow-up. RESULTS: Data of 40 patients were included (40% female, 30% ccTGA, median age 48 (44-53) years). Five patients discontinued therapy during titration. Median follow-up was 24 (12-36) months. The maximal dose was tolerated by 49% of patients. No episodes of hyperkalaemia or renal function decline occurred. Six-minute walking distance increased significantly after 6 months of treatment (569±16 to 597±16 m, p=0.016). Serum N-terminal-prohormone brain natriuretic peptide (NT-proBNP) levels decreased significantly after 3 months (567 (374-1134) to 404 (226-633) ng/L, p<0.001). Small, yet consistent echocardiographic improvements in sRV function were observed after 6 months (sRV global longitudinal strain: -11.1±0.5% to -12.6±0.7%, p<0.001, and fractional area change: 20% (16%-24%) to 26% (19%-30%), p<0.001). The linear mixed-effects model illustrated that after first follow-up moment, no time effect was present for the parameters. CONCLUSIONS: Treatment with sacubitril/valsartan was associated with a low rate of adverse effects in this adult sRV cohort. Persisting improvement in 6-minute walking test distance, NT-proBNP levels and echocardiographic parameters of sRV function was observed in an on-treatment analysis and showed no differential response based on sex or anatomy.

8.
Clin Chem Lab Med ; 61(10): 1719-1729, 2023 09 26.
Article in English | MEDLINE | ID: mdl-37071928

ABSTRACT

OBJECTIVES: The clinical use of soluble transferrin receptor (sTfR) as an iron status indicator is hindered by a lack of assay standardization and common reference ranges and decision thresholds. In 2009, the WHO and National Institute for Biological Standards and Controls (NIBSC) released a sTfR reference material (RM), 07/202, for assay standardization; however, a comprehensive, formal commutability study was not conducted. METHODS: This study evaluated the commutability of WHO 07/202 sTfR RM and human serum pools and the impacts of their use as common calibrators. Commutability was assessed for six different measurement procedures (MPs). Serum pools were prepared according to updated CLSI C37-A procedures (C37) or non-C37 procedures. The study design and analyses were based on Parts 2 and 3 of the 2018 IFCC Commutability in Metrological Traceability Working Group's Recommendations for Commutability Assessment. WHO 07/202 and serum pools were used for instrument/assay and mathematical recalibration, respectively, to determine if their use decreases inter-assay measurement variability for clinical samples. RESULTS: The WHO 07/202 RM dilutions were commutable for all 6 MPs assessed and, when used for instrument calibration, decreased inter-assay variability from 208 to 55.7 %. Non-C37 and C37 serum pools were commutable for all 6 MPs assessed and decreased inter-assay variability from 208 to 13.8 % and 4.6 %, respectively, when used for mathematical recalibration. CONCLUSIONS: All materials evaluated, when used as common calibrators, substantially decreased inter-assay sTfR measurement variability. MP calibration to non-C37 and C37 serum pools may reduce the sTfR IMPBR to a greater extent than WHO 07/202 RM.


Subject(s)
Receptors, Transferrin , Serum , Humans , Reference Standards , Calibration , World Health Organization
9.
J Cardiovasc Dev Dis ; 10(4)2023 Apr 20.
Article in English | MEDLINE | ID: mdl-37103059

ABSTRACT

In the transposition of the great arteries (TGA), alterations in hemodynamics and oxygen saturation could result in fibrotic remodeling, but histological studies are scarce. We aimed to investigate fibrosis and innervation state in the full spectrum of TGA and correlate findings to clinical literature. Twenty-two human postmortem TGA hearts, including TGA without surgical correction (n = 8), after Mustard/Senning (n = 6), and arterial switch operation (ASO, n = 8), were studied. In newborn uncorrected TGA specimens (1 day-1.5 months), significantly more interstitial fibrosis (8.6% ± 3.0) was observed compared to control hearts (5.4% ± 0.8, p = 0.016). After the Mustard/Senning procedure, the amount of interstitial fibrosis was significantly higher (19.8% ± 5.1, p = 0.002), remarkably more in the subpulmonary left ventricle (LV) than in the systemic right ventricle (RV). In TGA-ASO, an increased amount of fibrosis was found in one adult specimen. The amount of innervation was diminished from 3 days after ASO (0.034% ± 0.017) compared to uncorrected TGA (0.082% ± 0.026, p = 0.036). In conclusion, in these selected postmortem TGA specimens, diffuse interstitial fibrosis was already present in newborn hearts, suggesting that altered oxygen saturations may already impact myocardial structure in the fetal phase. TGA-Mustard/Senning specimens showed diffuse myocardial fibrosis in the systemic RV and, remarkably, in the LV. Post-ASO, decreased uptake of nerve staining was observed, implicating (partial) myocardial denervation after ASO.

10.
Clin Biochem ; 116: 42-51, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36940844

ABSTRACT

BACKGROUND: Accurate and reliable measurement of human serum free thyroxine (FT4) is critical for the diagnosis and treatment of thyroid diseases. However, concerns have been raised regarding the performance of FT4 measurements in patient care. Centers for Disease Control and Prevention Clinical Standardization Programs (CDC-CSP) address these concerns by creating a FT4 standardization program to standardize FT4 measurements. The study aims to develop a highly accurate and precise candidate Reference Measurement Procedure (cRMP), as one key component of CDC-CSP, for standardization of FT4 measurements. METHODS: Serum FT4 was separated from protein-bound thyroxine with equilibrium dialysis (ED) following the recommended conditions in the Clinical and Laboratory Standards Institute C45-A guideline and the published RMP [20,21,23]. FT4 in dialysate was directly quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS) without derivatization. Gravimetric measurements of specimens and calibrator solutions, calibrator bracketing, isotope dilution, enhanced chromatographic resolution, and T4 specific mass transitions were used to ensure the accuracy, precision, and specificity of the cRMP. RESULTS: The described cRMP agreed well with the established RMP and two other cRMPs in an interlaboratory comparison study. The mean biases of each method to the overall laboratory mean were within ±2.5%. The intra-day, inter-day, and total imprecision for the cRMP were within 4.4%. The limit of detection was 0.90 pmol/L, which was sufficiently sensitive to determine FT4 for patients with hypothyroidism. The structural analogs of T4 and endogenous components in dialysate did not interfere with the measurements. CONCLUSION: Our ED-LC-MS/MS cRMP provides high accuracy, precision, specificity, and sensitivity for FT4 measurement. The cRMP can serve as a higher-order standard for establishing measurement traceability and provide an accuracy base for the standardization of FT4 assays.


Subject(s)
Tandem Mass Spectrometry , Thyroxine , Humans , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Renal Dialysis , Dialysis Solutions , Reference Standards
11.
Clin Chem Lab Med ; 61(9): 1605-1611, 2023 08 28.
Article in English | MEDLINE | ID: mdl-36994743

ABSTRACT

OBJECTIVES: Free thyroxine (FT4) in serum is routinely measured in clinical practice to diagnose and monitor thyroid disease. Due to its concentration in picomolar range and the delicate equilibrium of free and protein-bound T4, accurate measurement is challenging. As a consequence, large inter-method differences in FT4 results exists. Optimal method design and standardization of the FT4 measurement is therefore necessary. The IFCC Working Group for Standardization of Thyroid Function Tests proposed a reference system with a conventional reference measurement procedure (cRMP) for FT4 in serum. In this study, we describe our FT4 candidate cRMP and its validation in clinical samples. METHODS: This candidate cRMP is based on equilibrium dialysis (ED) combined with determination of T4 with an isotope-dilution liquid chromatography tandem mass-spectrometry (ID-LC-MS/MS) procedure and was developed according to the endorsed conventions. Its accuracy, reliability, and comparability was investigated using human sera. RESULTS: It was shown that the candidate cRMP adhered to the conventions and its accuracy, precision, and robustness were adequate in serum of healthy volunteers. CONCLUSIONS: Our candidate cRMP measures FT4 accurately and performs well in serum matrix.


Subject(s)
Tandem Mass Spectrometry , Thyroxine , Humans , Chromatography, Liquid/methods , Reproducibility of Results , Tandem Mass Spectrometry/methods , Renal Dialysis , Isotopes , Reference Standards
12.
J Cardiovasc Dev Dis ; 10(3)2023 Mar 17.
Article in English | MEDLINE | ID: mdl-36975893

ABSTRACT

Baffle leaks are a frequently encountered and often overlooked complication after the atrial switch procedure for transposition of the great arteries. Baffle leaks are present in up to 50% of non-selected patients, and while they initially may not cause clear symptoms, they can complicate the hemodynamic course and influence the prognosis in this complex patient group. A shunt from the pulmonary venous atrium (PVA) to the systemic venous atrium (SVA) can lead to pulmonary overflow and subpulmonary left ventricular (LV) volume overload, while a shunt from the SVA to the PVA can result in (exercise-associated) cyanosis and paradoxical embolism. We report three cases of baffle leaks in patients with systemic right ventricular (sRV) failure late after the atrial switch procedure. Two symptomatic patients who presented with exercise-associated cyanosis due to SVA to PVA shunting over the baffle leak underwent successful percutaneous baffle leak closure with a septal occluder device. One patient with overt sRV failure and signs of subpulmonary LV volume overload due to PVA to SVA shunting was managed conservatively, as baffle leak closure was expected to lead to an increase in sRV end-diastolic pressure and aggravation of sRV dysfunction. These three cases illustrate the considerations made, challenges faced, and necessity of a patient-tailored approach when addressing baffle leaks.

13.
Clin Chem ; 69(3): 251-261, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36644914

ABSTRACT

BACKGROUND: Medical results generated by European CE Marking for In Vitro Diagnostic or in-house tests should be traceable to higher order reference measurement systems (RMS), such as International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)-endorsed reference measurement procedures (RMPs) and reference materials. Currently, serum apolipoprotein (a) [apo(a)] is recognized as a novel risk factor for cardiovascular risk assessment and patient management. The former RMS for serum apo(a) is no longer available; consequently, an International System of Units (SI)-traceable, ideally multiplexed, and sustainable RMS for apo(a) is needed. METHODS: A mass spectrometry (MS)-based candidate RMP (cRMP) for apo(a) was developed using quantitative bottom-up proteomics targeting 3 proteotypic peptides. The method was provisionally validated according to ISO 15193 using a single human serum based calibrator traceable to the former WHO-IFCC RMS. RESULTS: The quantitation of serum apo(a) was by design independent of its size polymorphism, was linear from 3.8 to 456 nmol/L, and had a lower limit of quantitation for apo(a) of 3.8 nmol/L using peptide LFLEPTQADIALLK. Interpeptide agreement showed Pearson Rs of 0.987 and 0.984 for peptides GISSTVTGR and TPENYPNAGLTR, and method comparison indicated good correspondence (slopes 0.977, 1.033, and 1.085 for LFLEPTQADIALLK, GISSTVTGR, and TPENYPNAGLTR). Average within-laboratory imprecision of the cRMP was 8.9%, 11.9%, and 12.8% for the 3 peptides. CONCLUSIONS: A robust, antibody-independent, MS-based cRMP was developed as higher order RMP and an essential part of the apo(a) traceability chain and future RMS. The cRMP fulfils predefined analytical performance specifications, making it a promising RMP candidate in an SI-traceable MS-based RMS for apo(a).


Subject(s)
Peptides , Serum , Humans , Apoprotein(a) , Mass Spectrometry , Reference Standards , Calibration
14.
Clin Chem ; 69(3): 262-272, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36644921

ABSTRACT

BACKGROUND: Elevated concentrations of lipoprotein(a) [Lp(a)] are directly related to an increased risk of cardiovascular diseases, making it a relevant biomarker for clinical risk assessment. However, the lack of global standardization of current Lp(a) measurement procedures (MPs) leads to inconsistent patient care. The International Federation for Clinical Chemistry and Laboratory Medicine working group on quantitating apolipoproteins by mass spectrometry (MS) aims to develop a next-generation SI (International system of units)-traceable reference measurement system consisting of a MS-based, peptide-calibrated reference measurement procedure (RMP) and secondary serum-based reference materials (RMs) certified for their apolipoprotein(a) [apo(a)] content. To reach measurement standardization through this new measurement system, 2 essential requirements need to be fulfilled: a sufficient correlation among the MPs and appropriate commutability of future serum-based RMs. METHODS: The correlation among the candidate RMP (cRMP) and immunoassay-based MPs was assessed by measuring a panel of 39 clinical samples (CS). In addition, the commutability of 14 different candidate RMs was investigated. RESULTS: Results of the immunoassay-based MPs and the cRMPs demonstrated good linear correlations for the CS but some significant sample-specific differences were also observed. The results of the commutability study show that RMs based on unspiked human serum pools can be commutable with CS, whereas human pools spiked with recombinant apo(a) show different behavior compared to CS. CONCLUSIONS: The results of this study show that unspiked human serum pools are the preferred candidate secondary RMs in the future SI-traceable Lp(a) Reference Measurement System.


Subject(s)
Chemistry, Clinical , Lipoprotein(a) , Humans , Immunoassay , Mass Spectrometry , Reference Standards
15.
J Electrocardiol ; 74: 94-100, 2022.
Article in English | MEDLINE | ID: mdl-36057190

ABSTRACT

INTRODUCTION: Application of the chronic thromboembolic pulmonary hypertension (CTEPH) rule out criteria (manual electrocardiogram [ECG] reading and N-terminal pro-brain natriuretic peptide [NTproBNP] test) can rule out CTEPH in pulmonary embolism (PE) patients with persistent dyspnea (InShape II algorithm). Increased pulmonary pressure may also be identified using automated ECG-derived ventricular gradient optimized for right ventricular pressure overload (VG-RVPO). METHOD: A predefined analysis of the InShape II study was performed. The diagnostic performance of the VG-RVPO for the detection of CTEPH and the incremental diagnostic value of the VG-RVPO as new rule-out criteria in the InShape II algorithm were evaluated. RESULTS: 60 patients were included; 5 (8.3%) were ultimately diagnosed with CTEPH. The mean baseline VG-RVPO (at time of PE diagnosis) was -18.12 mV·ms for CTEPH patients and - 21.57 mV·ms for non-CTEPH patients (mean difference 3.46 mV·ms [95%CI -29.03 to 35.94]). The VG-RVPO (after 3-6 months follow-up) normalized in patients with and without CTEPH, without a clear between-group difference (mean Δ VG-RVPO of -8.68 and - 8.42 mV·ms respectively; mean difference of -0.25 mV·ms, [95%CI -12.94 to 12.44]). The overall predictive accuracy of baseline VG-RVPO, follow-up RVPO and Δ VG-RVPO for CTEPH was moderate to poor (ROC AUC 0.611, 0.514 and 0.539, respectively). Up to 76% of the required echocardiograms could have been avoided with VG-RVPO criteria replacing the InShape II rule-out criteria, however at cost of missing up to 80% of the CTEPH diagnoses. CONCLUSION: We could not demonstrate (additional) diagnostic value of VG-RVPO as standalone test or as on top of the InShape II algorithm.


Subject(s)
Hypertension, Pulmonary , Pulmonary Embolism , Humans , Electrocardiography , Hypertension, Pulmonary/complications , Hypertension, Pulmonary/diagnosis , Pulmonary Embolism/complications , Pulmonary Embolism/diagnosis
16.
Eur Heart J Open ; 2(4): oeac031, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35919578

ABSTRACT

Aims: An anomalous coronary artery originating from the opposite sinus of Valsalva (ACAOS) with an interarterial course can be assessed using computed tomography angiography (CTA) for the presence of high-risk characteristics associated with sudden cardiac death. These features include a slit-like ostium, acute angle take-off, proximal luminal narrowing, and an intramural segment. To date, no robust CTA criteria exist to determine the presence of an intramural segment. We aimed to deduct new CTA parameters to distinguish an intramural course of interarterial ACAOS. Methods and results: Twenty-five patients with an interarterial ACAOS (64% female, mean age 46 years, 88% right ACAOS) from two academic hospitals were evaluated. Inclusion criteria were the availability of a preoperative CTA scan (0.51 mm slice thickness) and peroperative confirmation of the intramural segment. Using multiplanar reconstruction of the CTA, the distance between the lumen of the aorta and the lumen of the ACAOS [defined as 'interluminal space' (ILS)] was assessed at 2 mm intervals along the intramural segment. Analysis showed a mean ILS of 0.69 ± 0.15 mm at 2 mm from the ostium. At the end of the intramural segment where the ACAOS becomes non-intramural, the mean ILS was significantly larger (1.27 ± 0.29 mm, P < 0.001). Interobserver agreement evaluation showed good reproducibility (intraclass correlation coefficient 0.77, P < 0.001). Receiver operator characteristic analysis demonstrated that at a cut-off ILS of <0.95 mm, an intramural segment can be diagnosed with 100% sensitivity and 84% specificity. Conclusion: The ILS is introduced as a novel and robust CTA parameter to identify an intramural course of interarterial ACAOS. An ILS of <0.95 mm is indicative of an intramural segment.

18.
Front Cardiovasc Med ; 9: 870459, 2022.
Article in English | MEDLINE | ID: mdl-35620520

ABSTRACT

Background: Patients with transposition of the great arteries (TGA) after an atrial switch or congenitally corrected TGA (ccTGA) are prone to systemic right ventricular (sRV) failure. Tricuspid valve (TV) regurgitation aggravates sRV dysfunction. Timely TV surgery stabilizes sRV function, yet the development of atrioventricular (AV)-conduction disturbances in the course of sRV failure can contribute to sRV dysfunction through pacing-induced dyssynchrony. This study aims to explore the incidence, timing, and functional consequences of AV-block requiring ventricular pacing after TV surgery in patients with sRV. Methods: Consecutive adolescent and adult patients with an sRV who underwent TV surgery between 1989 and 2020 and followed-up at our center were included in this observational cohort study. Results: The data of 28 patients (53% female, 57% ccTGA, and a mean age at surgery 38 ± 13 years) were analyzed. The mean follow-up was 9.7 ± 6.8 years. Of the remaining 22 patients at the risk of developing high degree AV-block after TV surgery, 9 (41%) developed an indication for chronic ventricular pacing during follow-up, of which 5 (56%) within 24 months postoperatively (3 prior to hospital discharge). The QRS duration, a surrogate marker for dyssynchrony, was significantly higher in patients with chronic left ventricular pacing than in patients with native AV-conduction (217 ± 24 vs. 116 ± 23 ms, p = 0.000), as was the heart failure biomarker NT-pro-BNP [2,746 (1,242-6,879) vs. 495 (355-690) ng/L, p = 0.004] and the percentage of patients with ≥1 echocardiographic class of deterioration of systolic sRV function (27 vs. 83%, p = 0.001). Of the patients receiving chronic subpulmonary ventricular pacing (n = 12), 9 (75%) reached the composite endpoint of progressive heart failure [death, ventricular assist device implantation, or upgrade to cardiac resynchronization therapy (CRT)]. Only 4 (31%) patients with native AV-conduction (n = 13) reached this composite endpoint (p = 0.027). Conclusion: Patients with a failing sRV who undergo TV surgery are prone to develop AV-conduction abnormalities, with 41% developing an indication for chronic ventricular pacing during 10 years of follow-up. Patients with chronic subpulmonary ventricular pacing have a significantly longer QRS complex duration, have higher levels of the heart failure biomarker NT-pro-BNP, and are at a higher risk of deterioration of systolic sRV function and progressive heart failure.

19.
JAMA Pediatr ; 176(7): 699-714, 2022 Jul 01.
Article in English | MEDLINE | ID: mdl-35467725

ABSTRACT

Importance: Appropriately established pediatric reference intervals are critical to the clinical decision-making process and should reflect the physiologic changes that occur during healthy child development. Reference intervals used in pediatric care today remain highly inconsistent across a broad range of common clinical biomarkers. Observations: This narrative review assesses biomarker-specific pediatric reference intervals and their clinical utility with respect to the underlying biological changes occurring during development. Pediatric reference intervals from PubMed-indexed articles published from January 2015 to April 2021, commercial laboratory websites, study cohorts, and pediatric reference interval books were all examined. Although large numbers of pediatric reference intervals are published for some biomarkers, very few are used by clinical and commercial laboratories. The patterns, extent, and timing of biomarker changes are highly variable, particularly during developmental stages with rapid physiologic changes. However, many pediatric reference intervals do not capture these changes and thus do not accurately reflect the underlying biochemistry of development, resulting in significant inconsistencies between reference intervals. Conclusions and Relevance: There is a need to correctly describe the biochemistry of child development as well as to identify strategies to develop accurate and consistent pediatric reference intervals for improved pediatric care.


Subject(s)
Family , Biomarkers , Child , Clinical Decision-Making , Humans , Reference Values
20.
J Am Soc Nephrol ; 33(8): 1448-1458, 2022 08.
Article in English | MEDLINE | ID: mdl-35396262

ABSTRACT

Full-length parathyroid hormone (PTH 1-84) is crucial for the regulation of calcium and phosphate homeostasis and bone remodeling. PTH 1-84 is metabolized into various PTH fragments, which are measured with varying levels of efficiency by PTH immunoassays. These PTH fragments, which increase in serum as CKD progresses, could potentially modulate the effects of PTH 1-84 and contribute to CKD-associated bone disorders. To obtain a true biologic representation of total PTH bioactivity, it is necessary to measure not only PTH 1-84 but also PTH fragments that are present in circulation. Traditional second-generation PTH immunoassays collectively measure PTH 1-84, PTH fragments, and post-translationally modified PTH 1-84, making it difficult to accurately predict the character of underlying renal osteodystrophy. This review highlights current advances in methods available for PTH measurement and the clinical relevance of PTH fragments in CKD. We emphasize the usefulness of mass spectrometry as a potential reference method for PTH measurement.


Subject(s)
Chronic Kidney Disease-Mineral and Bone Disorder , Renal Insufficiency, Chronic , Bone and Bones , Humans , Mass Spectrometry , Parathyroid Hormone , Peptide Fragments
SELECTION OF CITATIONS
SEARCH DETAIL
...