1.
Invest Radiol ; 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38923436

ABSTRACT

OBJECTIVES: Clinical experience regarding the use of dedicated photon-counting breast CT (PC-BCT) for diagnosis of breast microcalcifications is scarce. This study systematically compares the detection and classification of breast microcalcifications using a dedicated breast photon-counting CT, especially designed for examining the breast, in comparison with digital breast tomosynthesis (DBT). MATERIALS AND METHODS: This is a prospective intraindividual study on women with DBT screening-detected BI-RADS-4/-5 microcalcifications who underwent PC-BCT before biopsy. PC-BCT images were reconstructed with a noninterpolated spatial resolution of 0.15 × 0.15 × 0.15 mm (reconstruction mode 1 [RM-1]) and with 0.3 × 0.3 × 0.3 mm (reconstruction mode 2 [RM-2]), plus thin-slab maximum intensity projection (MIP) reconstructions. Two radiologists independently rated the detection of microcalcifications in direct comparison with DBT on a 5-point scale. The distribution and morphology of microcalcifications were then rated according to BI-RADS. The size of the smallest discernible microcalcification particle was measured. For PC-BCT, the average glandular dose was determined by Monte Carlo simulations; for DBT, the information provided by the DBT system was used. RESULTS: Between September 2022 and July 2023, 22 participants (mean age, 61; range, 42-85 years) with microcalcifications (16 malignant; 6 benign) were included. In 2/22 with microcalcifications in the posterior region, microcalcifications were not detectable on PC-BCT, likely because they were not included in the PC-BCT volume. In the remaining 20 participants, microcalcifications were detectable. With high between-reader agreement (κ > 0.8), conspicuity of microcalcifications was rated similar for DBT and MIPs of RM-1 (mean, 4.83 ± 0.38 vs 4.86 ± 0.35) (P = 0.66), but was significantly lower (P < 0.05) for the remaining PC-BCT reconstructions: 2.11 ± 0.92 (RM-2), 2.64 ± 0.80 (MIPs of RM-2), and 3.50 ± 1.23 (RM-1). Identical distribution qualifiers were assigned for PC-BCT and DBT in 18/20 participants, with excellent agreement (κ = 0.91), whereas identical morphologic qualifiers were assigned in only 5/20, with poor agreement (κ = 0.44). The median size of smallest discernible microcalcification particle was 0.2 versus 0.6 versus 1.1 mm in DBT versus RM-1 versus RM-2 (P < 0.001), likely due to blooming effects. Average glandular dose was 7.04 mGy (PC-BCT) versus 6.88 mGy (DBT) (P = 0.67). CONCLUSIONS: PC-BCT allows reliable detection of in-breast microcalcifications as long as they are not located in the posterior part of the breast and allows assessment of their distribution, but not of their individual morphology.

2.
Eur Radiol ; 32(11): 7430-7438, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35524784

ABSTRACT

OBJECTIVES: Levonorgestrel-releasing intrauterine contraceptive devices (LNG-IUDs) are designed to exhibit only local hormonal effects. There is an ongoing debate on whether LNG-IUDs can have side effects similar to systemic hormonal medication. Benign background parenchymal enhancement (BPE) in dynamic contrast-enhanced (DCE) MRI has been established as a sensitive marker of hormonal stimulation of the breast. We investigated the association between LNG-IUD use and BPE in breast MRI to further explore possible systemic effects of LNG-IUDs. METHODS: Our hospital database was searched to identify premenopausal women without personal history of breast cancer, oophorectomy, and hormone replacement or antihormone therapy, who had undergone standardized DCE breast MRI at least twice, once with and without an LNG-IUD in place. To avoid confounding aging-related effects on BPE, half of included women had their first MRI without, the other half with, LNG-IUD in place. Degree of BPE was analyzed according to the ACR categories. Wilcoxon-matched-pairs signed-rank test was used to compare the distribution of ACR categories with vs. without LNG-IUD. RESULTS: Forty-eight women (mean age, 46 years) were included. In 24/48 women (50% [95% CI: 35.9-64.1%]), ACR categories did not change with vs. without LNG-IUDs. In 23/48 women (48% [33.9-62.1%]), the ACR category was higher with vs. without LNG-IUDs; in 1/48 (2% [0-6%]), the ACR category was lower with vs. without LNG-IUDs. The change of ACR category depending on the presence or absence of an LNG-IUD proved highly significant (p < 0.001). CONCLUSION: The use of an LNG-IUD can be associated with increased BPE in breast MRI, providing further evidence that LNG-IUDs do have systemic effects. KEY POINTS: • The use of levonorgestrel-releasing intrauterine contraceptive devices is associated with increased background parenchymal enhancement in breast MRI. • This suggests that hormonal effects of these devices are not only confined to the uterine cavity, but may be systemic. • Potential systemic effects of levonorgestrel-releasing intrauterine contraceptive devices should therefore be considered.


Subject(s)
Intrauterine Devices, Copper , Intrauterine Devices, Medicated , Female , Humans , Middle Aged , Levonorgestrel/adverse effects , Intrauterine Devices, Medicated/adverse effects , Intrauterine Devices, Copper/adverse effects , Breast/diagnostic imaging , Magnetic Resonance Imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...