Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Ann Plast Surg ; 74(4): 462-6, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25749211

ABSTRACT

BACKGROUND: Nodal status is the most significant prognostic factor in melanoma. No study has examined the relationship between lymphoscintigraphy, γ probe counts, harvested nodes, and nodal status. METHODS: Two-hundred sixty two patients were identified who underwent sentinel lymph node biopsy for melanoma between 2001 and 2010. Clinicopathologic and treatment information was collected. The number of lymph nodes and basins demonstrated on lymphoscintigraphy was compared to those at surgery. γ Probe counts were compared. RESULTS: Median age was 54.5 years (range, 18-90 years) with 52.3% male. Average Breslow depth was 2.0 (1.9) mm; 99.6% of lymphoscintigraphy studies identified at least 1 basin, 80% showed only 1 (range, 0-4). Lymphoscintigraphy identified on average 1.5 (0.9) sentinel nodes and 31% with secondary node. Surgery excised on average 2.6 (1.4) nodes involving 1.2 (0.5) basins; 17.6% had a positive sentinel lymph node. There was no difference in the sum or average of γ counts between positive and negative sentinel lymph node groups (P = 0.2, P = 0.5). When comparing lymphoscintigraphy and surgical excision, the correlation of lymphatic basins was r = 0.67 and of lymph node numbers was r = 0.33. CONCLUSIONS: Lymphoscintigraphy should be used to identify the proper lymphatic basins for a sentinel node procedure, however, the removal of nodes must continue until the background count is less than 10%. The correlation of lymph node number identified on lymphoscintigraphy to surgical excision is weak. γ Probe counts cannot be used to differentiate positive from negative nodes and the positive lymph node is not always the hottest node.


Subject(s)
Lymphoscintigraphy , Melanoma/diagnostic imaging , Preoperative Care/methods , Sentinel Lymph Node Biopsy , Skin Neoplasms/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Lymphatic Metastasis , Male , Melanoma/pathology , Melanoma/surgery , Middle Aged , Retrospective Studies , Skin Neoplasms/pathology , Skin Neoplasms/surgery , Young Adult
2.
Surg Endosc ; 29(11): 3246-50, 2015 Nov.
Article in English | MEDLINE | ID: mdl-25612548

ABSTRACT

BACKGROUND: Inguinal hernia repair, laparoscopic or open, is one of the most frequently performed operations in general surgery. Postoperative urinary retention (POUR) can occur in 0.2-35 % of patients after inguinal hernia repair. The primary objective of this study was to determine the incidence of POUR after inguinal hernia repair. As a secondary goal, we sought to determine whether perioperative and patient factors predicted urinary retention. METHODS: This study is a retrospective review of patients who underwent inguinal hernia repair with synthetic mesh at the Medical College of Wisconsin from January 2007 to June 2012. Procedures were performed by four surgeons. Clinical information and perioperative outcomes were collected up to hospital discharge. Urinary retention was defined as need for urinary catheterization postoperatively. RESULTS: A total of 192 patients were included in the study (88 bilateral, 46 %) and (104 unilateral, 54 %). The majority of subjects (76 %) underwent laparoscopic repair. The overall POUR rate was 13 %, with 25 of 192 patients requiring a Foley catheter prior to discharge. POUR was significantly associated with bilateral hernia repairs (p = 0.04), BMI ≥ 35 kg/m(2) (p = 0.05) and longer operative times (p = 0.03). Based on odds ratio (OR) estimates, for every 10-min increase in operative time, an 11 % increase in the odds of urinary retention is expected (OR 1.11, CI 1.004-1.223; p = 0.04). For every 10-min increase in operative time, an 11 % increase in POUR is expected. CONCLUSIONS: Bilateral hernia repairs, BMI ≥ 35 kg/m(2), and operative time are significant predictors of POUR. These factors are important to determine potential risk to patients and interventions such as strict fluid administration, use of catheters, and potential premedication.


Subject(s)
Hernia, Inguinal/surgery , Herniorrhaphy/adverse effects , Operative Time , Postoperative Complications/epidemiology , Urinary Retention/epidemiology , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Incidence , Laparoscopy/adverse effects , Male , Middle Aged , Postoperative Complications/etiology , Prognosis , Retrospective Studies , Urinary Retention/etiology , Wisconsin/epidemiology , Young Adult
3.
J Pediatr Orthop ; 33(2): 212-5, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23389578

ABSTRACT

INTRODUCTION: It is common for pediatric patients with a history of hip dysplasia to undergo anteroposterior (AP) and frog-leg (FL) lateral radiographs to monitor development of the hip. Because of sensitivity of pediatric tissues to ionizing radiation, we sought to document the relationship between AP and FL radiographs and to determine which image was better to assess acetabular dysplasia. METHODS: An Institutional Review Board-approved, retrospective review was conducted on 33 patients screened for hip dysplasia at a single institution. We sought to determine whether either film was more likely to be qualitatively better in position and whether there were differences in acetabular measures between the 2 radiographs. Standard measurements on AP and FL radiographs were made by 5 observers on 2 different occasions to assess interobserver and intraobserver variability. RESULTS: The mean age was 23+1 months, and 80% were female; none of the children had hip dysplasia. There was no statistical significance in the quotient of pelvic rotation (AP 1.2 + 0.1 degrees and FL 1.1 + 0.1 degrees; P = 0.84). There was a statistical difference in obturator height in mm (AP 16.0 + 0.3 and FL 17.8 + 0.2; P = 7.2E-10). The mean intraobserver variability for the acetabular index was 1.8 + 0.2 and 1.7 + 0.2 degrees for AP and FL alignments, respectively (P = 0.58), and the mean interobserver variability was 1.7 + 0.1 and 1.7 + 0.1 degrees, respectively (P = 0.75). The measurements of linear variability between the AP and FL showed no statistical significant difference with the exception of the left Hilgenreiner distance in mm (AP 1.00 + 0.08 and FL 0.81 + 0.08; P = 0.02). DISCUSSION: These results demonstrate that there is little clinical difference in variability of positioning and rotational variables between AP and FL radiographs for hip dysplasia. These results indicate that either image could be used assess to acetabular dysplasia thus decreasing risks of ionizing radiation. LEVEL OF EVIDENCE: Level III.


Subject(s)
Acetabulum/diagnostic imaging , Hip Dislocation/diagnostic imaging , Hip Joint/diagnostic imaging , Acetabulum/abnormalities , Child, Preschool , Female , Hip Joint/pathology , Humans , Infant , Male , Observer Variation , Pelvis , Radiography , Retrospective Studies , Rotation
SELECTION OF CITATIONS
SEARCH DETAIL
...