Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Nat Prod ; 83(4): 1334-1351, 2020 04 24.
Article in English | MEDLINE | ID: mdl-32281793

ABSTRACT

There is an active and growing interest in cannabis female inflorescence (Cannabis sativa) for medical purposes. Therefore, a definition of its quality attributes can help mitigate public health risks associated with contaminated, substandard, or adulterated products and support sound and reproducible basic and clinical research. As cannabis is a heterogeneous matrix that can contain a complex secondary metabolome with an uneven distribution of constituents, ensuring its quality requires appropriate sampling procedures and a suite of tests, analytical procedures, and acceptance criteria to define the identity, content of constituents (e.g., cannabinoids), and limits on contaminants. As an independent science-based public health organization, United States Pharmacopeia (USP) has formed a Cannabis Expert Panel, which has evaluated specifications necessary to define key cannabis quality attributes. The consensus within the expert panel was that these specifications should differentiate between cannabis chemotypes. Based on the secondary metabolite profiles, the expert panel has suggested adoption of three broad categories of cannabis. These three main chemotypes have been identified as useful for labeling based on the following cannabinoid constituents: (1) tetrahydrocannabinol (THC)-dominant chemotype; (2) intermediate chemotype with both THC and cannabidiol (CBD); and (3) CBD-dominant chemotype. Cannabis plants in each of these chemotypes may be further subcategorized based on the content of other cannabinoids and/or mono- and sesquiterpene profiles. Morphological and chromatographic tests are presented for the identification and quantitative determination of critical constituents. Limits for contaminants including pesticide residues, microbial levels, mycotoxins, and elemental contaminants are presented based on toxicological considerations and aligned with the existing USP procedures for general tests and assays. The principles outlined in this review should be able to be used as the basis of public quality specifications for cannabis inflorescence, which are needed for public health protection and to facilitate scientific research on cannabis safety and therapeutic potential.


Subject(s)
Cannabidiol/chemistry , Cannabinoids/analysis , Cannabis/chemistry , Dronabinol/chemistry , Cannabinoids/chemistry , Hallucinogens/chemistry , Hallucinogens/metabolism , Humans , Inflorescence/chemistry
2.
Vet Med (Auckl) ; 11: 45-55, 2020.
Article in English | MEDLINE | ID: mdl-32346530

ABSTRACT

PURPOSE: The use of veterinary low tetrahydrocannabinol (THC) Cannabis sativa (ie, hemp) products has increased in popularity for a variety of pet ailments. Low-THC Cannabis sativa is federally legal for sale and distribution in the USA, and the rise in internet commerce has provided access to interested consumers, with minimal quality control. MATERIALS AND METHODS: We performed an internet word search of "hemp extract and dog" or "CBD product and dog" and analyzed 29 products that were using low-THC Cannabis sativa extracts in their production of supplements. All products were tested for major cannabinoids including cannabidiol (CBD), ∆9-tetrahydrocannabinol (THC), cannabigerol (CBG), and other minor cannabinoids, as well as their carboxylic acid derivatives (CBDA, THCA, CBGA) using an ISO/IEC 17025 certified laboratory. Products were also tested for major terpenes and heavy metals to understand constituents in the hemp plants being extracted and distributed. RESULTS: All products were below the federal limit of 0.3% THC with variable amounts of CBD (0-88 mg/mL or g). Only two products did not supply a CBD or total cannabinoid concentration on their packaging or website, while 22/29 could supply a certificate of analysis (COA) from a third-party laboratory. Ten of the 27 products were within 10% of the total cannabinoid concentrations of their label claim with a median concentration of 93% of claims (0-154%). Heavy metal contamination was found in 4/29 products, with lead being the most prevalent contaminant (3/29). CONCLUSION: The products analyzed had highly variable concentrations of CBD or total cannabinoids with only 18 of 29 being appropriately labeled according to current FDA non-medication, non-dietary supplement or non-food guidelines. Owners and veterinarians wanting to utilize CBD-rich Cannabis sativa products should be aware of low-concentration products and should obtain a COA enabling them to fully discuss the implications of use and calculated dosing before administering to pets.

3.
F1000Res ; 5: 2471, 2016.
Article in English | MEDLINE | ID: mdl-27853518

ABSTRACT

Background: The presence of bacteria and fungi in medicinal or recreational Cannabis poses a potential threat to consumers if those microbes include pathogenic or toxigenic species. This study evaluated two widely used culture-based platforms for total yeast and mold (TYM) testing marketed by 3M Corporation and Biomérieux, in comparison with a quantitative PCR (qPCR) approach marketed by Medicinal Genomics Corporation. Methods: A set of 15 medicinal Cannabis samples were analyzed using 3M and Biomérieux culture-based platforms and by qPCR to quantify microbial DNA. All samples were then subjected to next-generation sequencing and metagenomics analysis to enumerate the bacteria and fungi present before and after growth on culture-based media. Results: Several pathogenic or toxigenic bacterial and fungal species were identified in proportions of >5% of classified reads on the samples, including Acinetobacter baumannii, Escherichia coli, Pseudomonas aeruginosa, Ralstonia pickettii, Salmonella enterica, Stenotrophomonas maltophilia, Aspergillus ostianus, Aspergillus sydowii, Penicillium citrinum and Penicillium steckii. Samples subjected to culture showed substantial shifts in the number and diversity of species present, including the failure of Aspergillus species to grow well on either platform. Substantial growth of Clostridium botulinum and other bacteria were frequently observed on one or both of the culture-based TYM platforms. The presence of plant growth promoting (beneficial) fungal species further influenced the differential growth of species in the microbiome of each sample. Conclusions: These findings have important implications for the Cannabis and food safety testing industries.

4.
J Chromatogr A ; 1362: 278-93, 2014 Oct 03.
Article in English | MEDLINE | ID: mdl-25200534

ABSTRACT

Scaling is regularly done in chromatography either to transfer a successfully designed method of analysis developed in one system to another system, or to scale-up a separation method developed in analytical scale to preparative scale. For liquid chromatography there are well-tested guidelines for scaling, which makes it a routine job. For supercritical fluid chromatography (SFC), on the other hand, neither do we have any well-understood principles behind scaling nor do we know how far the strategies applied in LC could be applicable to SFC. In this article, we have addressed these issues and proposed a rule applicable for scaling isocratic methods between different SFC systems and column dimensions under commonly used operating temperatures and pressures. We have shown that the scale-up and method transfer techniques used in LC can be applied to SFC, provided we ensure that both the original and the target systems in SFC operate at the same average density. The current article will present the theory, discuss the extents of applicability of this rule, and outline its limitations. In an accompanying article implementation of this rule in various practical situations will be presented.


Subject(s)
Chromatography, Supercritical Fluid/methods , Biomechanical Phenomena , Limit of Detection , Particle Size , Pressure , Temperature , Viscosity
5.
J Chromatogr A ; 1060(1-2): 153-63, 2004 Dec 10.
Article in English | MEDLINE | ID: mdl-15628158

ABSTRACT

The important experimental design criteria for an accelerated low-pH RPLC column stability test are discussed. The influence of method variables on the amount and rate of retention-loss and the final optimized parameters for the accelerated low-pH RPLC stability test are presented. The retention-loss curves for selected C8 and C18 stationary phases are compared. These studies indicate that ligand chain length, functionality and bonding density play an important role in determining the low-pH stability of a stationary phase. Additionally, elemental analysis data are used to infer the mechanism responsible for the observed retention-loss under low-pH conditions.


Subject(s)
Chromatography, High Pressure Liquid/instrumentation , Hydrogen-Ion Concentration , Temperature
6.
Anal Chem ; 75(24): 6781-8, 2003 Dec 15.
Article in English | MEDLINE | ID: mdl-14670036

ABSTRACT

The characterization and evaluation of three novel 5-microm HPLC column packings, prepared using ethyl-bridged hybrid organic/inorganic materials, is described. These highly spherical hybrid particles, which vary in specific surface area (140, 187, and 270 m(2)/g) and average pore diameter (185, 148, and 108 A), were characterized by elemental analysis, SEM, and nitrogen sorption analysis and were chemically modified in a two-step process using octadecyltrichlorosilane and trimethylchlorosilane. The resultant bonded materials had an octadecyl surface concentration of 3.17-3.35 micromol/m(2), which is comparable to the coverage obtained for an identically bonded silica particle (3.44 micromol/m(2)) that had a surface area of 344 m(2)/g. These hybrid materials were shown to have sufficient mechanical strength under conditions normally employed for traditional reversed-phase HPLC applications, using a high-pressure column flow test. The chromatographic properties of the C(18) bonded hybrid phases were compared to a C(18) bonded silica using a variety of neutral and basic analytes under the same mobile-phase conditions. The hybrid phases exhibited similar selectivity to the silica-based column, yet had improved peak tailing factors for the basic analytes. Column retentivity increased with increasing particle surface area. Elevated pH aging studies of these hybrid materials showed dramatic improvement in chemical stability for both bonded and unbonded hybrid materials compared to the C(18) bonded silica phase, as determined by monitoring the loss in column efficiency through 140-h exposure to a pH 10 triethylamine mobile phase at 50 degrees C.

SELECTION OF CITATIONS
SEARCH DETAIL
...