Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Healthcare (Basel) ; 11(7)2023 Apr 04.
Article in English | MEDLINE | ID: mdl-37046960

ABSTRACT

Mixed results have been reported for the relationship between personality and hangover, but recent findings have indicated that regulatory and attentional control processes may relate to hangover severity and the impact of a hangover on completing daily activities. This study aimed to explore how these factors relate to hangover severity, hangover impact, and to unhealthy alcohol use. In total, 108 participants completed a survey, rating the severity and impact of their last-experienced hangover and completing measures of the above factors. Separate multiple linear regressions were conducted to analyse each outcome (severity, impact, unhealthy drinking). For severity, the overall regression was significant (Adj. R2 = 0.46, p < 0.001), with the attentional control factor 'Focusing' (B = -0.096, p = 0.011), and personality factor 'Agreeableness' (B = 0.072, p = 0.005) predicting severity. For impact, the overall regression was significant (Adj. R2 = 0.41, p < 0.001) with the attentional control factor 'Shifting' (B = -0.252, p = 0.021), personality factors 'Extraversion' (B = 0.225, p = 0.009) and 'Agreeableness' (B = -0.156, p = 0.042), and hangover severity (B = 1.603, p < 0.001) predicting impact. For unhealthy drinking, the overall regression model was significant (Adj. R2 = 0.45, p < 0.001) with emotion dysregulation factors 'Awareness' (B = 0.301, p = 0.044) and 'Impulse Control' (B = 0.381, p = 0.011) predicting unhealthy drinking. These findings add to our understanding of the heterogeneity of hangover experience and highlight that attentional control, emotion regulation, and personality play important roles in the experience and impact of a hangover.

2.
J Med Radiat Sci ; 69(4): 473-483, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35715996

ABSTRACT

INTRODUCTION: The magnitude and impact of rotational error is unclear in rectal cancer radiation therapy. This study evaluates rotational errors in rectal cancer patients, and investigates the feasibility of planning target volume (PTV) margin reduction to decrease organs at risk (OAR) irradiation. METHODS: In this study, 10 patients with rectal cancer were retrospectively selected. Rotational errors were assessed through image registration of daily cone beam computed tomography (CBCT) and planning CT scans. Two reference treatment plans (TPR ) with PTV margins of 5 mm and 10 mm were generated for each patient. Pre-determined rotational errors (±1°, ±3°, ±5°) were simulated to produce six manipulated treatment plans (TPM ) from each TPR . Differences in evaluated dose-volume metrics between TPR and TPM of each rotation were compared using Wilcoxon Signed-Rank Test. Clinical compliance was investigated for statistically significant dose-volume metrics. RESULTS: Mean rotational errors in pitch, roll and yaw were -0.72 ± 1.81°, -0.04 ± 1.36° and 0.38 ± 0.96° respectively. Pitch resulted in the largest potential circumferential displacement of clinical target volume (CTV) at 1.42 ± 1.06 mm. Pre-determined rotational errors resulted in statistically significant differences in CTV, small bowel, femoral heads and iliac crests (P < 0.05). Only small bowel and iliac crests failed clinical compliance, with majority in the PTV 10 mm margin group. CONCLUSION: Rotational errors affected clinical compliance for OAR dose but exerted minimal impact on CTV coverage even with reduced PTV margins. Both PTV margin reduction and rotational correction decreased irradiated volume of OAR. PTV margin reduction to 5 mm is feasible, and rotational corrections are recommended in rectal patients to further minimise OAR irradiation.


Subject(s)
Radiotherapy, Intensity-Modulated , Rectal Neoplasms , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage , Retrospective Studies , Organs at Risk/radiation effects , Rectal Neoplasms/diagnostic imaging , Rectal Neoplasms/radiotherapy
3.
J Med Radiat Sci ; 68(4): 379-388, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34288534

ABSTRACT

INTRODUCTION: Chemoradiotherapy (CRT) is the standard treatment for locally advanced cervical and vaginal cancer. It is associated with high haematological toxicity (HT) that can lead to treatment interruptions and cancelled chemotherapy cycles, reducing the potential effectiveness of this regimen. Bone marrow sparing (BMS) utilising volumetric modulated arc therapy (VMAT) is one method to reduce dose to the active bone marrow (ABM) so that HT rates are reduced. The aim of this paper was to assess whether BMS-VMAT can effectively spare the ABM whilst maintaining clinically acceptable target and organ-at-risk (OAR) doses. METHODS: Twenty gynaecological cancer patients treated with definitive CRT at the Liverpool/Macarthur Cancer Therapy centres between 2015 and 2020 were retrospectively included. ABM was delineated based on fluorodeoxyglucose positron emission tomography (FDG-PET) imaging. Weekly blood tests and ABM dose parameters at the V10Gy, V20Gy, V30Gy, V40Gy and Dmean were assessed on original plans for any potential correlation with grade 2+ HT. Replanned with VMAT for BMS, various dose parameters were compared with the original plan to assess for any significant differences. RESULTS: Active bone marrow doses were significantly reduced (P < 0.001 for all parameters) in BMS-VMAT plans, and significant improvements in target and OAR coverage were found compared with the original plans. Compared with VMAT only, target and OARs were comparable. No significant correlations between HT and ABM doses were found. CONCLUSION: Bone marrow sparing volumetric modulated arc therapy can significantly reduce dose to the active bone marrow whilst maintaining acceptable target and OAR doses. Future prospective trials are needed to evaluate the clinical impact of BMS on toxicity and compliance.


Subject(s)
Radiotherapy, Intensity-Modulated , Vaginal Neoplasms , Bone Marrow , Feasibility Studies , Female , Humans , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated/adverse effects , Retrospective Studies
4.
Front Psychiatry ; 12: 787166, 2021.
Article in English | MEDLINE | ID: mdl-35153857

ABSTRACT

The experience of psychosis can present additional difficulties for parents, over and above the normal challenges of parenting. Although there is evidence about parenting interventions specifically targeted at parents with affective disorders, anxiety, and borderline personality disorder, there is currently limited evidence for parents with psychotic disorders. It is not yet known what, if any, interventions exist for this population, or what kinds of evaluations have been conducted. To address this, we conducted a scoping review to determine (1) what parenting interventions have been developed for parents with psychosis (either specifically for, or accessible by, this client group), (2) what components these interventions contain, and (3) what kinds of evaluations have been conducted. The eligibility criteria were broad; we included any report of an intervention for parents with a mental health diagnosis, in which parents with psychosis were eligible to take part, that had been published within the last 20 years. Two reviewers screened reports and extracted the data from the included reports. Thirty-eight studies of 34 interventions were included. The findings show that most interventions have been designed either for parents with any mental illness or parents with severe mental illness, and only two interventions were trialed with a group of parents with psychosis. After noting clusters of intervention components, five groups were formed focused on: (1) talking about parental mental illness, (2) improving parenting skills, (3) long-term tailored support for the whole family, (4) groups for parents with mental illness, and (5) family therapy. Twenty-three quantitative evaluations and 13 qualitative evaluations had been conducted but only eight interventions have or are being evaluated using a randomized controlled trial (RCT). More RCTs of these interventions are needed, in addition to further analysis of the components that are the most effective in changing outcomes for both the parent and their children, in order to support parents with psychosis and their families.

5.
J Med Imaging Radiat Oncol ; 61(4): 517-521, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28256052

ABSTRACT

INTRODUCTION: In recent years, using radiation energies greater than 10 MV in patients with implantable cardioverter defibrillators (ICDs) has been contra-indicated due to the risk of a power on reset (POR) occurring. The ICD is often greater than 30 cm from the treatment field and subject to scatter radiation only. The aim of this study was to use recent patient cases to verify published failure rates and treatment recommendations. METHOD: Five patients with ICDs who experienced a device malfunction during radiation therapy treatments were identified in three Sydney hospitals between 2008 and 2012. The types of treatments delivered during these events were assessed. Further assessment of all ICD patients at one Sydney hospital during this time was carried out to assess the rate of ICD failure during high energy treatments using 18 MV. RESULTS: All ICDs that suffered malfunctions were exposed to scatter radiation only. All were exposed to partial or exclusive irradiation using 18 MV photons. Accumulated doses to the ICDs were estimated to be well below accepted dose limits found in literature. One centre reported a 22.2% rate of POR during exposure to 18 MV radiation therapy during this time frame. CONCLUSIONS: Where possible, radiation therapy using energies greater than 10 MV should be avoided for ICD patients. While the use of these energies carries a risk of failure, it must be weighed against potential benefit to the patient requiring treatment if no alternatives are available. Stringent monitoring of these patients, including regular cardiac device checks and ECG monitoring is recommended if treatment is to proceed with energies greater than 10 MV.


Subject(s)
Defibrillators, Implantable , Equipment Failure Analysis , Prostatic Neoplasms/radiotherapy , Radiation, Ionizing , Rectal Neoplasms/radiotherapy , Aged , Aged, 80 and over , Equipment Failure , Female , Humans , Male , New South Wales , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...