Cardiovasc Eng Technol ; 11(4): 362-380, 2020 08.
Article in English | MEDLINE | ID: mdl-32405926

ABSTRACT

PURPOSE: Currently used cannulae for extracorporeal carbon dioxide removal (ECCO2R) are associated with complications such as thrombosis and distal limb ischemia, especially for long-term use. We hypothesize that the risk of these complications is reducible by attaching hemodynamically optimized grafts to the patient's vessels. In this study, as a first step towards a long-term stable ECCO2R connection, we investigated the feasibility of a venovenous connection to the common iliac veins. To ensure its applicability, the drainage of reinfused blood (recirculation) and high wall shear stress (WSS) must be avoided. METHODS: A reference model was selected for computational fluid dynamics, on the basis of the analysis of imaging data. Initially, a sensitivity analysis regarding recirculation was conducted using as variables: blood flow, the distance of drainage and return to the iliocaval junction, as well as the diameter and position of the grafts. Subsequently, the connection was optimized regarding recirculation and the WSS was evaluated. We validated the simulations in a silicone model traversed by dyed fluid. RESULTS: The simulations were in good agreement with the validation measurements (mean deviation 1.64%). The recirculation ranged from 32.1 to 0%. The maximum WSS did not exceed 5.57 Pa. The position and diameter of the return graft show the highest influence on recirculation. A correlation was ascertained between recirculation and WSS. Overall, an inflow jet directed at a vessel wall entails not only high WSS, but also a flow separation and thereby an increased recirculation. Therefore, return grafts aligned to the vena cava are crucial. CONCLUSION: In conclusion, a connection without recirculation could be feasible and therefore provides a promising option for a long-term ECCO2R connection.


Subject(s)
Blood Vessel Prosthesis Implantation , Carbon Dioxide/blood , Extracorporeal Membrane Oxygenation , Iliac Vein/surgery , Models, Cardiovascular , Biomarkers/blood , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Computer Simulation , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Feasibility Studies , Hemodynamics , Humans , Iliac Vein/physiopathology , Numerical Analysis, Computer-Assisted , Prosthesis Design , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...