Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Materials (Basel) ; 16(11)2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37297263

ABSTRACT

Over the past few years, alternative power supplies to either supplement or replace batteries for electronic textile and wearable applications have been sought, with the development of wearable solar energy harvesting systems gaining significant interest. In a previous publication the authors reported a novel concept to craft a yarn capable of harvesting solar energy by embedding miniature solar cells within the fibers of a yarn (solar electronic yarns). The aim of this publication is to report the development of a large-area textile solar panel. This study first characterized the solar electronic yarns, and then analyzed the solar electronic yarns once woven into double cloth woven textiles; as part of this study, the effect of different numbers of covering warp yarns on the performance of the embedded solar cells was explored. Finally, a larger woven textile solar panel (510 mm × 270 mm) was constructed and tested under different light intensities. It was observed that a PMAX = 335.3 ± 22.4 mW of energy could be harvested on a sunny day (under 99,000 lux lighting conditions).

2.
Materials (Basel) ; 16(5)2023 Feb 25.
Article in English | MEDLINE | ID: mdl-36903036

ABSTRACT

Falls can be detrimental to the quality of life of older people, and therefore the ability to detect falls is beneficial, especially if the person is living alone and has injured themselves. In addition, detecting near falls (when a person is imbalanced or stumbles) has the potential to prevent a fall from occurring. This work focused on the design and engineering of a wearable electronic textile device to monitor falls and near-falls and used a machine learning algorithm to assist in the interpretation of the data. A key driver behind the study was to create a comfortable device that people would be willing to wear. A pair of over-socks incorporating a single motion sensing electronic yarn each were designed. The over-socks were used in a trial involving 13 participants. The participants performed three types of activities of daily living (ADLs), three types of falls onto a crash mat, and one type of near-fall. The trail data was visually analyzed for patterns, and a machine learning algorithm was used to classify the data. The developed over-socks combined with the use of a bidirectional long short-term memory (Bi-LSTM) network have been shown to be able to differentiate between three different ADLs and three different falls with an accuracy of 85.7%, ADLs and falls with an accuracy of 99.4%, and ADLs, falls, and stumbles (near-falls) with an accuracy of 94.2%. In addition, results showed that the motion sensing E-yarn only needs to be present in one over-sock.

3.
Sensors (Basel) ; 21(8)2021 Apr 15.
Article in English | MEDLINE | ID: mdl-33920830

ABSTRACT

Overexposure to hand transmitted vibrations (HTVs) from prolonged use of vibrating power tools can result in severe injuries. By monitoring the exposure of a worker to HTVs, overexposure, and injury, can be mitigated. An ideal HTV-monitoring system would measure vibration were it enters the body, which for many power tools will be the palm and fingers, however this is difficult to achieve using conventional transducers as they will affect the comfort of the user and subsequently alter the way that the tool is held. By embedding a transducer within the core of a textile yarn, that can be used to produce a glove, vibration can be monitored close to where it enters the body without compromising the comfort of the user. This work presents a vibration-sensing electronic yarn that was created by embedding a commercially available accelerometer within the structure of a yarn. These yarns were subsequently used to produce a vibration-sensing glove. The purpose of this study is to characterize the response of the embedded accelerometer over a range of relevant frequencies and vibration amplitudes at each stage of the electronic yarn's manufacture to understand how the yarn structure influences the sensors response. The vibration-sensing electronic yarn was subsequently incorporated into a fabric sample and characterized. Finally, four vibration-sensing electronic yarns were used to produce a vibration-sensing glove that is capable of monitoring vibration at the palm and index finger.


Subject(s)
Textiles , Vibration , Electronics , Gloves, Protective , Hand
4.
Sensors (Basel) ; 20(20)2020 Oct 21.
Article in English | MEDLINE | ID: mdl-33096633

ABSTRACT

An increased use in wearable, mobile, and electronic textile sensing devices has led to a desire to keep these devices continuously powered without the need for frequent recharging or bulky energy storage. To achieve this, many have proposed integrating energy harvesting capabilities into clothing: solar energy harvesting has been one of the most investigated avenues for this due to the abundance of solar energy and maturity of photovoltaic technologies. This review provides a comprehensive, contemporary, and accessible overview of electronic textiles that are capable of harvesting solar energy. The review focusses on the suitability of the textile-based energy harvesting devices for wearable applications. While multiple methods have been employed to integrate solar energy harvesting with textiles, there are only a few examples that have led to devices with textile properties.

5.
Materials (Basel) ; 13(5)2020 Mar 09.
Article in English | MEDLINE | ID: mdl-32182823

ABSTRACT

Electronically active yarn (E-yarn) pioneered by the Advanced Textiles Research Group of Nottingham Trent University contains a fine conductive copper wire soldered onto a package die, micro-electro-mechanical systems device or flexible circuit. The die or circuit is then held within a protective polymer packaging (micro-pod) and the ensemble is inserted into a textile sheath, forming a flexible yarn with electronic functionality such as sensing or illumination. It is vital to be able to wash E-yarns, so that the textiles into which they are incorporated can be treated as normal consumer products. The wash durability of E-yarns is summarized in this publication. Wash tests followed a modified version of BS EN ISO 6330:2012 procedure 4N. It was observed that E-yarns containing only a fine multi-strand copper wire survived 25 cycles of machine washing and line drying; and between 5 and 15 cycles of machine washing followed by tumble-drying. Four out of five temperature sensing E-yarns (crafted with thermistors) and single pairs of LEDs within E-yarns functioned correctly after 25 cycles of machine washing and line drying. E-yarns that required larger micro-pods (i.e., 4 mm diameter or 9 mm length) were less resilient to washing. Only one out of five acoustic sensing E-yarns (4 mm diameter micro-pod) operated correctly after 20 cycles of washing with either line drying or tumble-drying. Creating an E-yarn with an embedded flexible circuit populated with components also required a relatively large micro-pod (diameter 0.93 mm, length 9.23 mm). Only one embedded circuit functioned after 25 cycles of washing and line drying. The tests showed that E-yarns are suitable for inclusion in textiles that require washing, with some limitations when larger micro-pods were used. Reduction in the circuit's size and therefore the size of the micro-pod, may increase wash resilience.

6.
Sci Rep ; 8(1): 16205, 2018 11 01.
Article in English | MEDLINE | ID: mdl-30385876

ABSTRACT

A novel photodiode-embedded yarn has been presented and characterized for the first time, offering new possibilities for applications including monitoring body vital signs (including heart rate, blood oxygen and skin temperature) and environmental conditions (light, humidity and ultraviolet radiation). To create an E-Textile integrated with electronic devices that is comfortable, conformal, aesthetically pleasing and washable, electronic components are best integrated within the structure of a textile fabric in yarn form. The device is first encapsulated within a protective clear resin micro-pod before being covered in a fibrous sheath. The resin micro-pod and covering fibres have a significant effect on the nature of light received by the photoactive region of the device. This work characterised the effects of both encapsulating photodiodes within resin micro-pods and covering the micro-pod with a fibrous sheath on the opto-electronic parameters. A theoretical model is presented to provide an estimate for these effects and validated experimentally using two photodiode types and a range of different resin micro-pods. This knowledge may have wider applications to other devices with small-scale opto-electronic components. Wash tests confirmed that the yarns could survive multiple machine wash and drying cycles without deterioration in performance.

7.
Sensors (Basel) ; 18(7)2018 Jul 21.
Article in English | MEDLINE | ID: mdl-30037070

ABSTRACT

In medicine, temperature changes can indicate important underlying pathologies such as wound infection. While thermographs for the detection of wound infection exist, a textile substrate offers a preferable solution to the designs that exist in the literature, as a textile is very comfortable to wear. This work presents a fully textile, wearable, thermograph created using temperature-sensing yarns. As described in earlier work, temperature-sensing yarns are constructed by encapsulating an off-the-shelf thermistor into a polymer resin micro-pod and then embedding this within the fibres of a yarn. This process creates a temperature-sensing yarn that is conformal, drapeable, mechanically resilient, and washable. This work first explored a refined yarn design and characterised its accuracy to take absolute temperature measurements. The influence of contact errors with the refined yarns was explored seeing a 0.24 ± 0.03 measurement error when the yarn was held just 0.5 mm away from the surface being measured. Subsequently, yarns were used to create a thermograph. This work characterises the operation of the thermograph under a variety of simulated conditions to better understand the functionality of this type of textile temperature sensor. Ambient temperature, insulating material, humidity, moisture, bending, compression and stretch were all explored. This work is an expansion of an article published in The 4th International Conference on Sensor and Applications.


Subject(s)
Textiles , Thermography/instrumentation , Wearable Electronic Devices , Humans , Humidity , Polymers , Temperature
8.
Sensors (Basel) ; 18(5)2018 May 17.
Article in English | MEDLINE | ID: mdl-29772756

ABSTRACT

Overexposure to high levels of noise can cause permanent hearing disorders, which have a significant adverse effect on the quality of life of those affected. Injury due to noise can affect people in a variety of careers including construction workers, factory workers, and members of the armed forces. By monitoring the noise exposure of workers, overexposure can be avoided and suitable protective equipment can be provided. This work focused on the creation of a noise dosimeter suitable for use by members of the armed forces, where a discrete dosimeter was integrated into a textile helmet cover. In this way the sensing elements could be incorporated very close to the ears, providing a highly representative indication of the sound level entering the body, and also creating a device that would not interfere with military activities. This was achieved by utilising commercial microelectromechanical system microphones integrated within the fibres of yarn to create an acoustic sensing yarn. The acoustic sensing yarns were fully characterised over a range of relevant sound levels and frequencies at each stage in the yarn production process. The yarns were ultimately integrated into a knitted helmet cover to create a functional acoustic sensing helmet cover prototype.


Subject(s)
Health Surveys/methods , Military Personnel , Sound , Head Protective Devices , Health Surveys/instrumentation , Humans , Micro-Electrical-Mechanical Systems , Occupational Diseases/diagnosis , Tinnitus/diagnosis
9.
Sensors (Basel) ; 17(8)2017 Aug 05.
Article in English | MEDLINE | ID: mdl-28783067

ABSTRACT

Textiles provide an ideal structure for embedding sensors for medical devices. Skin temperature measurement is one area in which a sensor textile could be particularly beneficial; pathological skin is normally very sensitive, making the comfort of anything placed on that skin paramount. Skin temperature is an important parameter to measure for a number of medical applications, including for the early detection of diabetic foot ulcer formation. To this end an electronic temperature-sensor yarn was developed by embedding a commercially available thermistor chip into the fibres of a yarn, which can be used to produce a textile or a garment. As part of this process a resin was used to encapsulate the thermistor. This protects the thermistor from mechanical and chemical stresses, and also allows the sensing yarn to be washed. Building off preliminary work, the behaviour and performance of an encapsulated thermistor has been characterised to determine the effect of encapsulation on the step response time and absolute temperature measurements. Over the temperature range of interest only a minimal effect was observed, with step response times varying between 0.01-0.35 s. A general solution is presented for the heat transfer coefficient compared to size of the micro-pod formed by the encapsulation of the thermistor. Finally, a prototype temperature-sensing sock was produced using a network of sensing yarns as a demonstrator of a system that could warn of impending ulcer formation in diabetic patients.


Subject(s)
Textiles
10.
Sci Total Environ ; 559: 212-217, 2016 07 15.
Article in English | MEDLINE | ID: mdl-27062558

ABSTRACT

Forced aeration of horizontal subsurface flow constructed wetlands (HSSF CWs) is nowadays a recognized method to improve treatment efficiency, mainly in terms of ammonium removal. While numerous investigations have been reported testing constant aeration, scarce information can be found about the efficiency of intermittent aeration. This study aims at comparing continuous and intermittent aeration, establishing if there is an optimal regime that will increase treatment efficiency of HSSF CWs whilst minimizing the energy requirement. Full and intermittent aeration were tested in a pilot plant of three HSSF CWs (2.64m(2) each) fed with primary treated wastewater. One unit was fully aerated; one intermittently aerated (i.e. by setting a limit of 0.5mg/L dissolved oxygen within the bed) with the remaining unit not aerated as a control. Results indicated that intermittent aeration was the most successful operating method. Indeed, the coexistence of aerobic and anoxic conditions promoted by the intermittent aeration resulted in the highest COD (66%), ammonium (99%) and total nitrogen (79%) removals. On the other hand, continuous aeration promotes ammonium removal (99%), but resulted in nitrate concentrations in the effluent of up to 27mg/L. This study demonstrates the high potential of the intermittent aeration to increase wastewater treatment efficiency of CWs providing an extreme benefit in terms of the energy consumption.

11.
Magn Reson Med ; 76(4): 1224-35, 2016 10.
Article in English | MEDLINE | ID: mdl-26507239

ABSTRACT

PURPOSE: Asthma is a disease of increasing worldwide importance that calls for new investigative methods. Ex vivo lung tissue is being increasingly used to study functional respiratory parameters independent of confounding systemic considerations but also to reduce animal numbers and associated research costs. In this work, a straightforward laboratory method is advanced to probe dynamic changes in gas inhalation patterns by using an ex vivo small animal ovalbumin (OVA) model of human asthma. METHODS: Hyperpolarized (hp) (129) Xe was actively inhaled by the excised lungs exposed to a constant pressure differential that mimicked negative pleural cavity pressure. The method enabled hp (129) Xe MRI of airway responsiveness to intravenous methacholine (MCh) and airway challenge reversal through salbutamol. RESULTS: Significant differences were demonstrated between control and OVA challenged animals on global lung hp (129) Xe gas inhalation with P < 0.05 at MCh dosages above 460 µg. Spatial mapping of the regional hp gas distribution revealed an approximately three-fold increase in heterogeneity for the asthma model organs. CONCLUSION: The experimental results from this proof of concept work suggest that the ex vivo hp noble gas imaging arrangement and the applied image analysis methodology may be useful as an adjunct to current diagnostic techniques. Magn Reson Med 76:1224-1235, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Subject(s)
Asthma/diagnostic imaging , Asthma/physiopathology , Lung/diagnostic imaging , Lung/physiopathology , Magnetic Resonance Imaging/methods , Pulmonary Gas Exchange , Xenon Isotopes/pharmacokinetics , Administration, Inhalation , Animals , Computer Simulation , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Male , Models, Biological , Molecular Imaging/methods , Radiopharmaceuticals/administration & dosage , Radiopharmaceuticals/pharmacokinetics , Rats , Reproducibility of Results , Sensitivity and Specificity , Tissue Distribution , Xenon Isotopes/administration & dosage
12.
Magn Reson Imaging ; 32(1): 48-53, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24144493

ABSTRACT

Hyperpolarized (83)Kr has previously been demonstrated to enable MRI contrast that is sensitive to the chemical composition of the surface in a porous model system. Methodological advances have lead to a substantial increase in the (83)Kr hyperpolarization and the resulting signal intensity. Using the improved methodology for spin exchange optical pumping of isotopically enriched (83)Kr, internal anatomical details of ex vivo rodent lung were resolved with hyperpolarized (83)Kr MRI after krypton inhalation. Different (83)Kr relaxation times were found between the main bronchi and the parenchymal regions in ex vivo rat lungs. The T1 weighted hyperpolarized (83)Kr MRI provided a first demonstration of surface quadrupolar relaxation (SQUARE) pulmonary MRI contrast.


Subject(s)
Contrast Media/chemistry , Krypton/chemistry , Magnetic Resonance Imaging/methods , Animals , Bronchi/pathology , Gases , Image Processing, Computer-Assisted , Isotopes/chemistry , Lung/pathology , Male , Optics and Photonics , Pulmonary Surfactants/chemistry , Rats , Rats, Sprague-Dawley , Surface Properties , Time Factors
13.
J Magn Reson ; 237: 23-33, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24135800

ABSTRACT

As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp (129)Xe or hp (83)Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp (129)Xe handling, while (83)Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The (83)Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of (129)Xe in corresponding mixtures. The experimental setup also facilitated (129)Xe T1 relaxation measurements as a function of O2 concentration within excised lungs.


Subject(s)
Krypton/chemistry , Magnetic Resonance Imaging/methods , Xenon Isotopes/chemistry , Algorithms , Animals , Contrast Media , Gases , Image Interpretation, Computer-Assisted , Isotopes , Lung/anatomy & histology , Male , Oxygen/chemistry , Rats , Rats, Sprague-Dawley , Respiration, Artificial , Rubidium/chemistry
14.
PLoS One ; 8(8): e73468, 2013.
Article in English | MEDLINE | ID: mdl-24023683

ABSTRACT

Ex vivo rodent lung models are explored for physiological measurements of respiratory function with hyperpolarized (hp) (129)Xe MRI. It is shown that excised lung models allow for simplification of the technical challenges involved and provide valuable physiological insights that are not feasible using in vivo MRI protocols. A custom designed breathing apparatus enables MR images of gas distribution on increasing ventilation volumes of actively inhaled hp (129)Xe. Straightforward hp (129)Xe MRI protocols provide residual lung volume (RV) data and permit for spatially resolved tracking of small hp (129)Xe probe volumes during the inhalation cycle. Hp (129)Xe MRI of lung function in the excised organ demonstrates the persistence of post mortem airway responsiveness to intravenous methacholine challenges. The presented methodology enables physiology of lung function in health and disease without additional regulatory approval requirements and reduces the technical and logistical challenges with hp gas MRI experiments. The post mortem lung functional data can augment histological measurements and should be of interest for drug development studies.


Subject(s)
Dissection , Lung/physiology , Magnetic Resonance Imaging , Xenon , Animals , Guinea Pigs , Humans , Inhalation/physiology , Male , Pulmonary Ventilation/physiology , Rats , Rats, Sprague-Dawley , Reproducibility of Results , Residual Volume/physiology , Signal Processing, Computer-Assisted , Time Factors , Xenon Isotopes
15.
PLoS One ; 7(11): e49927, 2012.
Article in English | MEDLINE | ID: mdl-23209620

ABSTRACT

Hyperpolarized (hp) (129)Xe and hp (83)Kr for magnetic resonance imaging (MRI) are typically obtained through spin-exchange optical pumping (SEOP) in gas mixtures with dilute concentrations of the respective noble gas. The usage of dilute noble gases mixtures requires cryogenic gas separation after SEOP, a step that makes clinical and preclinical applications of hp (129)Xe MRI cumbersome. For hp (83)Kr MRI, cryogenic concentration is not practical due to depolarization that is caused by quadrupolar relaxation in the condensed phase. In this work, the concept of stopped flow SEOP with concentrated noble gas mixtures at low pressures was explored using a laser with 23.3 W of output power and 0.25 nm linewidth. For (129)Xe SEOP without cryogenic separation, the highest obtained MR signal intensity from the hp xenon-nitrogen gas mixture was equivalent to that arising from 15.5±1.9% spin polarized (129)Xe in pure xenon gas. The production rate of the hp gas mixture, measured at 298 K, was 1.8 cm(3)/min. For hp (83)Kr, the equivalent of 4.4±0.5% spin polarization in pure krypton at a production rate of 2 cm(3)/min was produced. The general dependency of spin polarization upon gas pressure obtained in stopped flow SEOP is reported for various noble gas concentrations. Aspects of SEOP specific to the two noble gas isotopes are discussed and compared with current theoretical opinions. A non-linear pressure broadening of the Rb D(1) transition was observed and taken into account for the qualitative description of the SEOP process.


Subject(s)
Krypton/chemistry , Magnetic Resonance Imaging/methods , Xenon Isotopes/chemistry , Humans , Isotopes , Lasers , Noble Gases/chemistry , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...