Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Chest ; 164(3): 757-769, 2023 09.
Article in English | MEDLINE | ID: mdl-37044158

ABSTRACT

BACKGROUND: The acute cardiovascular and pulmonary effects of contemporary electronic nicotine delivery systems (ENDS) in long-term users are not known. RESEARCH QUESTION: What are the cardiovascular and pulmonary responses to an acute 15-min product use challenge with ENDS and combustible cigarettes in regular nicotine-containing product users compared with control participants who do not use tobacco or vape? STUDY DESIGN AND METHODS: Observational challenge study before and after nicotine-containing product use of 395 individuals who used ENDS exclusively (n = 164; exhaled carbon monoxide level, < 5 parts per million [ppm]; positive urine NicCheck I [Mossman Associates] results, 82%; fourth-generation ENDS), participants who smoked cigarettes exclusively (n = 117; carbon monoxide level, > 5 ppm; positive urine NicCheck I results), and control participants (n = 114; carbon monoxide level, < 5 ppm; negative urine NicCheck I results). RESULTS: During the 15-min product challenge, cigarette users took a median of 14.0 puffs (interquartile range [IQR], 9.3 puffs); ENDS users took 9.0 puffs (IQR, 7.5 puffs; P < .001). After product challenge, compared with control participants, ENDS users showed greater increases in adjusted mean differences in systolic BP (5.6 mm Hg [95% CI, 4.4-6.8 mm Hg] vs 2.3 mm Hg [95% CI, 0.8-3.8 mm Hg]; P = .001), diastolic BP (4.2 mm Hg [95% CI, 3.3-5.0 mm Hg] vs 2.0 mm Hg [95% CI, 1.1-3.0 mm Hg; P = .003), and heart rate (4.8 beats/min [95% CI, 4.0-5.6 beats/min] vs -1.3 beats/min [95% CI, -2.2 to -0.3 beats/min]; P < .001) and greater reductions in brachial artery diameter (-0.011 cm [95% CI, -0.013 to 0.009 cm] vs -0.006 cm [95% CI, -0.004 to -0.009 cm]; P = .003), time-domain heart rate variability (-7.2 ms [95% CI, -10.5 to -3.7 ms] vs 3.6 ms [95% CI, 1.6-9.3 ms]; P = .001), and FEV1 (ENDS: -4.1 [95% CI, -5.4 to -2.8] vs control participants: -1.1 [95% CI, -2.7 to 0.6]; P = .005) with values similar to those of cigarette users. ENDS users performed worse than control participants on all exercise parameters, notably metabolic equivalents (METs; adjusted mean difference, 1.28 METs [95% CI, 0.73-1.83 METs]; P < .001) and 60-s heart rate recovery (adjusted mean difference, 2.9 beats/min [95% CI, 0.7-5.0 beats/min]; P = .008). INTERPRETATION: ENDS users had acute worsening of blood pressure, heart rate, and heart rate variability, as well as vasoconstriction, impaired exercise tolerance, and increased airflow obstruction after vaping, compared to control participants. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT03863509; URL: www. CLINICALTRIALS: gov.


Subject(s)
Electronic Nicotine Delivery Systems , Tobacco Products , Vaping , Humans , Carbon Monoxide , Nicotine/adverse effects , Vaping/adverse effects
2.
J Am Heart Assoc ; 11(5): e024142, 2022 03.
Article in English | MEDLINE | ID: mdl-35179037

ABSTRACT

Background We aimed to investigate novel grayscale ultrasound characteristics of the carotid and brachial arteries in people with HIV infection before and after starting initial antiretroviral therapy (ART). Methods and Results We performed grayscale ultrasound image analyses of the common carotid artery (CCA) and brachial artery before and after receipt of 1 of 3 randomly allocated ART regimens. We measured arterial wall echogenicity (grayscale median), contrast (gray-level difference statistic method), and entropy. These measures and their changes were compared with atherosclerotic cardiovascular disease risk factors, measures of HIV disease severity, and inflammatory biomarkers before and after ART. Changes in the grayscale measures were evaluated within and between ART arms. Among 201 ART-naïve people with HIV, higher systolic blood pressure, higher body mass index, lower CD4+ T cells, and non-Hispanic White race and ethnicity were associated independently with lower CCA grayscale median. Changes in each CCA grayscale measure from baseline to 144 weeks correlated with changes in soluble CD163: grayscale median (ρ=-0.17; P=0.044), gray-level difference statistic-contrast (ρ=-0.19; P=0.024), and entropy (ρ=-0.21; P=0.016). Within the atazanavir/ritonavir arm, CCA entropy increased (adjusted ß=0.023 [95% CI, 0.001-0.045]; P=0.04), but no other within-arm changes in grayscale measures were seen. Correlations of brachial artery grayscale measures were weaker. Conclusions In ART-naïve people with HIV, CCA grayscale ultrasound measures were associated with atherosclerotic cardiovascular disease risk factors and lower grayscale median was associated with lower CD4+ T cells. Reductions in soluble CD163 with initial ART were associated with improvements in all 3 CCA grayscale measures, suggesting that reductions in macrophage activation with ART initiation may lead to less arterial injury. Registration URL: https://clinicaltrials.gov/; Unique identifiers: NCT00811954; NCT00851799.


Subject(s)
Atherosclerosis , Cardiovascular Diseases , HIV Infections , Brachial Artery/diagnostic imaging , Carotid Arteries/diagnostic imaging , HIV Infections/complications , HIV Infections/drug therapy , Humans , Predictive Value of Tests , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...