1.
Nucl Med Commun ; 39(6): 533-538, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29578927

ABSTRACT

OBJECTIVE: Qualitative positron emission tomography (PET) myocardial perfusion imaging (MPI) scans are reconstructed with a delay after an injection of rubidium-82 (Rb) to ensure blood pool clearance and sufficient left ventricle to myocardium contrast. Our aim was to derive the minimal starting time of data reconstruction (STDR) after an injection of Rb for which the diagnostic value and image quality remained unaffected. MATERIALS AND METHODS: We retrospectively included 23 patients who underwent rest-stress Rb PET MPI using 740 MBq. Patients fulfilling one of the two criteria indicating a slow blood pool clearance (ejection fraction <50% and/or cardiac output <3 l/min) were included in a consecutive manner. PET images using five different STDRs (1:15-2:15 min) were reconstructed and compared with reference images (STDR of 2:30 min). Differences in the summed rest score greater than or equal to 3 and total perfusion deficit greater than 3% were considered to significantly influence the diagnostic value. In addition, image quality was scored by two experts as not interpretable, inferior, adequate, or excellent. RESULTS: The summed rest score differed greater than or equal to 3 from the reference in seven or more patients (≥30%) using STDR less than or equal to 2:00 min (P<0.02). STDR less than or equal to 1:30 min resulted in six or more patients (≥26%) with a total perfusion deficit difference greater than 3% (P<0.03).In addition, STDR less than or equal to 2:00 min resulted in a lower image quality (P<0.002) and STDR less than or equal to 2:15 min resulted in greater than or equal to two scans with noninterpretable image quality. CONCLUSION: STDR less than or equal to 2:15 min resulted in lower diagnostic value or insufficient image quality for qualitative PET MPI using 740 MBq Rb. An STDR of 2:30 min can be considered for clinical adoption.


Subject(s)
Image Processing, Computer-Assisted/methods , Myocardial Perfusion Imaging , Positron-Emission Tomography , Rubidium Radioisotopes , Aged , Female , Humans , Male , Retrospective Studies , Time Factors
2.
Nucl Med Commun ; 38(8): 708-714, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28703721

ABSTRACT

OBJECTIVES: Recommended rubidium-82 activities for relative myocardial perfusion imaging (MPI) using present-generation PET scanners may be unnecessarily high. Our aim was to derive the minimum activity for a reliable relative PET MPI assessment. MATERIALS AND METHODS: We analyzed 140 scans from 28 consecutive patients who underwent rest-stress MPI-PET (Ingenuity TF). Scans of 852, 682, 511, and 341 MBq were simulated from list-mode data and compared with a reference scan using 1023 MBq. Differences in the summed rest score, total perfusion deficit, and image quality were obtained between the reference and each of the simulated rest scans. Combined stress-rest scans obtained at a selected activity of 682 MBq were diagnostically interpreted by experts and outcome was compared with the reference scan interpretation. RESULTS: Differences in summed rest score more than or equal to 3 were found using 682, 511, and 341 MBq in two (7%), four (14%), and five (18%) patients, respectively. Differences in total perfusion deficit more than 7% were only found at 341 MBq in one patient. Image quality deteriorated significantly only for the 341 MBq scans (P<0.001). Interpretation of stress-rest scans did not differ between 682 and 1023 MBq scans. CONCLUSION: A significant reduction in administered Rb-82 activity is feasible in relative MPI. An activity of 682 MBq resulted in reliable diagnostic outcomes and image quality, and can therefore be considered for clinical adoption.


Subject(s)
Myocardial Perfusion Imaging/methods , Positron-Emission Tomography/methods , Rubidium Radioisotopes , Aged , Coronary Artery Disease/diagnostic imaging , Female , Humans , Male , Radioactive Tracers , Retrospective Studies