Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Oral Maxillofac Surg ; 28(2): 859-867, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38315402

ABSTRACT

PURPOSE: The aim of this retrospective study was to evaluate the outcomes of a two-piece implant system with a tube-in-tube internal connection after up to 15 years of clinical use. MATERIAL AND METHODS: A retrospective follow-up examination of patients treated with internal tube-in-tube implants between 2003 and 2006 was conducted. The implant survival rates, peri-implant conditions (marginal bone loss, bleeding on probing, plaque index, probing depth), and technical complications were determined. RESULTS: In total, 312 dental implants were placed in 152 patients. Of the original 152 patients enrolled, 245 implants in 112 patients were available for a follow-up evaluation after 11 to 15 years (mean observation time, 12.9 ± 1.1 years). The overall implant survival rate was 93.9%. Outcomes for MBL (1.49 ± 1.23 mm), PI (24.3 ± 22.2%), BOP (18.3 ± 28.7%), and PD (2.74 ± 1.21 mm) were observed. Selected parameters (time after implant surgery, smoking habits, bone augmentation (GBR)) showed an influence on MBL and PD. CONCLUSIONS: The internal tube-in-tube implant system showed favorable long-term results. The correlation of MBL and PD with the patient-specific factor smoking habit is in accordance with other studies. CLINICAL RELEVANCE: Camlog Root-Line implants with a tube-in-tube implant-abutment connection and a 1.6-mm polished neck configuration have demonstrated favorable long-term outcomes in daily clinical practice. However, it is important to note that these implants are no longer available on the market.


Subject(s)
Dental Implants , Humans , Male , Female , Retrospective Studies , Middle Aged , Cross-Sectional Studies , Adult , Aged , Follow-Up Studies , Dental Restoration Failure , Dental Prosthesis Design , Treatment Outcome , Alveolar Bone Loss/etiology , Dental Implantation, Endosseous
2.
Int J Implant Dent ; 4(1): 33, 2018 Nov 02.
Article in English | MEDLINE | ID: mdl-30386925

ABSTRACT

BACKGROUND: The performance of dental implants in controlled clinical studies is often investigated in homogenous populations. Observational studies are necessary to evaluate the outcome of implant restorations placed in real-life situations, according to standard practice, and to assess the needs of the patients. The aim of this non-interventional study was to reveal the survival, success, and general performance of CAMLOG SCREW-LINE implants and their restorations in daily dental practice. METHODS: Seventeen private practices across five countries participated in this prospective multicenter study. Patients received implants in the maxilla and mandible which were restored either with platform-matching or platform-switching abutments. Patients were followed-up for up to 5 years post-loading. Radiographs and clinical parameters were evaluated and patient satisfaction was evaluated. RESULTS: From a total of 196 patients planned, 185 patients with 271 implants were restored with abutments and fulfilled the follow-up inclusion criteria. Three implant failures were recorded, resulting in a cumulative survival rate of 98.6% after 5 years post-loading. One persistent complication of peri-implantitis occurred. The soft tissue health remained stable, and the papilla height improved after loading. At 5-year follow-up, the mean crestal bone loss was - 0.28 ± 0.60 mm; over 99% of patients reported satisfaction with the restoration as excellent or good. CONCLUSIONS: Implants placed and restored with both platform-matching and platform-switching abutments in daily dental private practice achieved excellent clinical outcomes with highly satisfied patients after 5 years of function, confirming the results obtained in well-controlled clinical trials.

SELECTION OF CITATIONS
SEARCH DETAIL
...