Hand (N Y) ; 14(6): 765-769, 2019 11.
Article in English | MEDLINE | ID: mdl-29661071

ABSTRACT

Background: The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. Methods: An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. Results: The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Conclusions: Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.


Subject(s)
Fluoroscopy/instrumentation , Hand/diagnostic imaging , Image Enhancement/instrumentation , Occupational Exposure/analysis , Radiation Exposure/analysis , Computer Simulation , Fluoroscopy/adverse effects , Fluoroscopy/methods , Humans , Image Enhancement/methods , Intraoperative Period
2.
J Hand Surg Am ; 44(1): 68.e1-68.e5, 2019 Jan.
Article in English | MEDLINE | ID: mdl-29934087

ABSTRACT

PURPOSE: During mini C-arm fluoroscopy, both the patient and surgical team are exposed to scatter radiation. The objective of this study was to quantify body, thyroid, and hand radiation exposure to surgeon and assistant during intraoperative use of flat panel mini C-arm fluoroscopy in hand and wrist surgical procedures. METHODS: Over 5 months, the surgeon's and assistant's radiation exposure was recorded during all osseous hand and wrist surgical procedures. Whole-body and thyroid radiation exposure were measured with 2 types of dosimeters: a photon thermoluminescence detector and a RaySafe i2 real-time dosimeter. Ring dosimeters were used to quantify hand radiation exposure. RESULTS: Mini C-arm fluoroscopy was used in 94 surgical procedures. Total fluoroscopy time was 1,996 seconds and varied between surgical procedures (range, 1-152 seconds; median, 11 seconds). No thermoluminescence detector photon dosimeter exceeded the threshold limit of 0.1 mSv. The RaySafe i2 real-time dosimeters recorded a cumulated dose of 0.029 mSv for the body and 0.012 mSv for the thyroid position of the surgeon. The assistant received a cumulated dose of 0.011 mSv for the body and 0.011 mSv for the thyroid position. The ring dosimeters showed a cumulated dosage of 1.28 mSv for the surgeon and 0.20 mSv for the assistant. CONCLUSIONS: Our results show that the surgeon's and assistant's body, thyroid, and hands were exposed to acceptable levels of scatter radiation during intraoperative use of the flat panel mini C-arm. The surgeon received the highest radiation exposure: 2.9% of the yearly radiation limits for the body, 0.05% for the thyroid position, and 2.56% for the hands. The assistant was exposed to less scatter radiation: 1.1% for the body, 0.04% for the thyroid, and 0.4% for the hands. CLINICAL RELEVANCE: This study quantified radiation levels to which surgeon and assistant are exposed during mini C-arm fluoroscopy in hand and wrist surgical procedures.


Subject(s)
Fluoroscopy , Intraoperative Period , Occupational Exposure/analysis , Radiation Exposure/analysis , Surgeons , Hand/radiation effects , Hand/surgery , Humans , Radiometry , Scattering, Radiation , Thyroid Gland/radiation effects , Wrist/radiation effects , Wrist/surgery