Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ecol Evol ; 13(7): e10331, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37484932

ABSTRACT

Detection is essential to studying and monitoring wild animals; however, detection is challenging for small endotherms that are nocturnal or best detected at night. Techniques such as trapping or spotlighting disturb focal species, and the effectiveness of spotlighting can be limited for cryptic species, resulting in low detection rates that hinder our ability to monitor and study some endotherms at night. Thermal scanners detect infrared wavelengths not otherwise visible to humans. With improvements in equipment size and cost, thermal scanners have emerged as a valuable tool for passive detection of endotherms. Here we seek to provide objective guidance on thermal tool selection to practitioners who wish to adopt such tools to detect and monitor small endotherms. We compared the efficacy of three handheld thermal scanners (of varying resolutions) and a traditional spotlight for detecting small, cryptic endotherms at night. Random arrays of artificially heated small bird models (representing small, cryptic endotherms) were established along transects in native grasslands that support a range of small threatened endotherms, including the Critically Endangered Plains-wanderer (Pedionomus torquatus). Transects were independently surveyed by five observers, blind to model locations and model density. Performance measures representing detection capability were assessed for all devices, and usability of each device was assessed with a survey completed by all observers. Detection rates, detection distances, and survey accuracy were greater for thermal scanners with resolutions of 320 × 240 and 640 × 480 than for the spotlight. A low-resolution thermal scope (160 × 120) performed poorly for all performance measures. There was a consensus among users that a video camera-style thermal scanner was most comfortable to hold and view while traversing the transect, as opposed to thermal scopes where users look directly through the lens. These results suggest that high-resolution thermal scanners (≥320 × 240) provide improved detection capabilities compared to traditional spotlights. Higher detection rates provide opportunities for detecting and monitoring small endotherms at night where this was once difficult or impossible.

2.
Heart Lung ; 47(4): 387-391, 2018.
Article in English | MEDLINE | ID: mdl-29858104

ABSTRACT

BACKGROUND: Sedation of mechanically ventilated patients should optimize comfort and safety while avoiding over-sedation and adverse outcomes. To our knowledge, characteristics associated with attaining target sedation are unknown. OBJECTIVES: Evaluate current sedation practice at a single center and explore which patient characteristics are associated with attaining target sedation. METHODS: This is a single-center, retrospective chart review of sedated, ventilated patients in a medical/surgical ICU. Demographic and clinical data were collected. Univariate and multivariate logistic regression analyses were used with attaining target sedation as the dependent variable. RESULTS: Of the 100 patients included (median 60.5 years), 50 attained target sedation. Univariate analyses (a = 0.10) revealed factors associated with target sedation were age (P = 0.08), history of alcohol abuse (P = 0.08), multiple comorbidities (P = 0.09), and delirium monitoring (P = 0.002). Multivariate analysis revealed an association between delirium monitoring/documentation and attaining target sedation (P = 0.005; OR 9.2; 95% CI 2.3-36.8). CONCLUSIONS: Patients without appropriate delirium monitoring/documentation had significantly reduced likelihood of achieving target sedation.


Subject(s)
Conscious Sedation/methods , Hypnotics and Sedatives/administration & dosage , Intensive Care Units/statistics & numerical data , Respiration, Artificial/statistics & numerical data , Adolescent , Adult , Aged , Aged, 80 and over , Conscious Sedation/adverse effects , Female , Humans , Hypnotics and Sedatives/adverse effects , Length of Stay/statistics & numerical data , Male , Middle Aged , North Carolina , Respiration, Artificial/adverse effects , Retrospective Studies , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...