Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Transplant ; 38(5): e15330, 2024 May.
Article in English | MEDLINE | ID: mdl-38716787

ABSTRACT

INTRODUCTION: Since the 2018 change in the US adult heart allocation policy, more patients are bridged-to-transplant on temporary mechanical circulatory support (tMCS). Previous studies indicate that durable left ventricular assist devices (LVAD) may lead to allosensitization. The goal of this study was to assess whether tMCS implantation is associated with changes in sensitization. METHODS: We included patients evaluated for heart transplants between 2015 and 2022 who had alloantibody measured before and after MCS implantation. Allosensitization was defined as development of new alloantibodies after tMCS implant. RESULTS: A total of 41 patients received tMCS before transplant. Nine (22.0%) patients developed alloantibodies following tMCS implantation: 3 (12.0%) in the intra-aortic balloon pump group (n = 25), 2 (28.6%) in the microaxial percutaneous LVAD group (n = 7), and 4 (44.4%) in the veno-arterial extra-corporeal membrane oxygenation group (n = 9)-p = .039. Sensitized patients were younger (44.7 ± 11.6 years vs. 54.3 ± 12.5 years, p = .044), were more likely to be sensitized at baseline - 3 of 9 (33.3%) compared to 2 out of 32 (6.3%) (p = .028) and received more transfusions with red blood cells (6 (66.6%) vs. 8 (25%), p = .02) and platelets (6 (66.6%) vs. 5 (15.6%), p = .002). There was no significant difference in tMCS median duration of support (4 [3,15] days vs. 8.5 [5,14.5] days, p = .57). Importantly, out of the 11 patients who received a durable LVAD after tMCS, 5 (45.5%) became sensitized, compared to 4 out of 30 patients (13.3%) who only had tMCS-p = .028. CONCLUSIONS: Our findings suggest that patients bridged-to-transplant with tMCS, without significant blood product transfusions and a subsequent durable LVAD implant, have a low risk of allosensitization. Further studies are needed to confirm our findings and determine whether risk of sensitization varies by type of tMCS and duration of support.


Subject(s)
Heart Transplantation , Heart-Assist Devices , Isoantibodies , Humans , Male , Female , Middle Aged , Isoantibodies/immunology , Isoantibodies/blood , Follow-Up Studies , Adult , Risk Factors , Prognosis , Retrospective Studies , Heart Failure/surgery , Heart Failure/therapy , Graft Rejection/etiology
2.
J Heart Lung Transplant ; 35(8): 1024-30, 2016 08.
Article in English | MEDLINE | ID: mdl-27316382

ABSTRACT

BACKGROUND: Immune allosensitization can be triggered by continuous-flow left ventricular assist devices (CF LVAD). However, the effect of this type of allosensitization on post-transplant outcomes remains controversial. This study examined the post-transplant course in a contemporary cohort of patients undergoing transplantation with and without LVAD bridging. METHODS: We included consecutive patients who were considered for cardiac transplant from 2006 to 2015. Serum alloantibodies were detected with single-antigen beads on the Luminex platform (One Lambda Inc., Canoga Park, CA). Allosensitization was defined as calculated panel reactive antibody (cPRA) > 10%. cPRA was determined at multiple times. LVAD-associated allosensitization was defined as development of cPRA > 10% in patients with cPRA ≤ 10% before LVAD implantation. Post-transplant outcomes of interest were acute cellular rejection (ACR), antibody-mediated rejection (AMR), and survival. RESULTS: Allosensitization status was evaluated in 268 patients (20% female). Mean age was 52 ± 12 years, and 132 (49.3%) received CF LVADs. After LVAD implant, 30 patients (23%) became newly sensitized, and the level of sensitization appeared to diminish in many of these patients while awaiting transplant. During the study period, 225 of 268 patients underwent transplant, and 43 did not. A CF LVAD was used to bridge 50% of the transplant recipients. Compared with patients without new sensitization or those already sensitized at baseline, the patients with LVAD-associated sensitization had a higher risk of ACR (p = 0.049) and higher risk of AMR (p = 0.018) but a similar intermediate-term post-transplant survival. The patients who did not receive a transplant had higher level of allosensitization, with a baseline cPRA of 20% vs 6% in those who received an allograft and a high risk (40%) of death during follow-up. CONCLUSIONS: New allosensitization takes place in > 20% of patents supported with CF LVADs. Among patients who undergo transplant, this results in a higher risk of ACR and AMR, but survival remains favorable, likely due to the efficacy of current management after transplant. However, mortality in sensitized patients who do not reach transplant remains high, and new approaches are necessary to meet the needs of this group of patients.


Subject(s)
Heart Transplantation , Female , Graft Rejection , Heart Failure , Heart-Assist Devices , Humans , Isoantibodies , Male , Middle Aged
3.
J Heart Lung Transplant ; 28(11): 1129-34, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19782589

ABSTRACT

BACKGROUND: Organ transplant candidates with serum antibodies directed against human leukocyte antigens (HLA) face longer waiting times and higher mortality while awaiting transplantation. This study examined the accuracy of virtual crossmatch, in which recipient HLA-specific antibodies, identified by solid-phase assays, are compared to the prospective donor HLA-type in heart transplantation. METHODS: We examined the accuracy of virtual crossmatch in predicting immune compatibility of donors and recipients in heart transplantation and clinical outcomes in immunologically sensitized heart transplant recipients in whom virtual crossmatch was used in allograft allocation. RESULTS: Based on analysis of 257 T-cell antihuman immunoglobulin complement-dependent cytotoxic (AHG-CDC) crossmatch tests, the positive predictive value of virtual crossmatch (the likelihood of an incompatible virtual crossmatch resulting in an incompatible T-cell CDC-AHG crossmatch) was 79%, and the negative predictive value of virtual crossmatch (the likelihood of a compatible virtual crossmatch resulting in a compatible T-cell CDC-AHG crossmatch) was 92%. When used in a cohort of 28 sensitized patients awaiting heart transplantation, 14 received allografts based on a compatible virtual crossmatch alone from donors in geographically distant locations. Compared with the other 14 sensitized patients who underwent transplant after a compatible prospective serologic crossmatch, the rejection rates and survival were similar. CONCLUSION: Our findings are evidence of the accuracy of virtual crossmatch and its utility in augmenting the opportunities for transplantation of sensitized patients.


Subject(s)
Heart Transplantation/immunology , Biomarkers/blood , Endomyocardial Fibrosis/epidemiology , Endomyocardial Fibrosis/mortality , Follow-Up Studies , Histocompatibility Testing/methods , Humans , Hypoxia-Inducible Factor 1, alpha Subunit/blood , Postoperative Complications/epidemiology , Postoperative Complications/immunology , Postoperative Complications/mortality , Postoperative Complications/prevention & control , Procollagen-Proline Dioxygenase/blood , Time Factors , User-Computer Interface , Vascular Endothelial Growth Factor A/blood
4.
Am J Physiol Endocrinol Metab ; 289(4): E710-5, 2005 Oct.
Article in English | MEDLINE | ID: mdl-15928023

ABSTRACT

This study was designed to examine activity of AMP-activated protein kinase kinase (AMPKK) in muscles from nontrained and endurance-trained rats. Rats were trained 5 days/wk, 2 h/day for 8 wk at a final intensity of 32 m/min up a 15% grade with 30-s sprints at 53 m/min every 10 min. Gastrocnemius muscles were stimulated in situ in trained and nontrained rats for 5 min at frequencies of 0.4/s and 1/s. Gastrocnemius LKB1 protein, a putative component of the AMPKK complex (LKB1, STRAD, and MO25), increased approximately twofold in response to training. Phosphorylation of AMP-activated protein kinase (AMPK) determined by Western blot and AMPK activity of immunoprecipitates (both isoforms) was increased at both stimulation rates in both trained and nontrained muscles. AMPKK activity was 73% lower in resuspended polyethylene glycol precipitates of muscle extracts from the trained compared with nontrained rats. AMPKK activity did not increase in either trained or nontrained muscle in response to electrical stimulation, even though phospho-AMPK did increase. These results suggest that AMPKK is activated during electrical stimulation of both trained and nontrained muscle by mechanisms other than covalent modification.


Subject(s)
Isometric Contraction/physiology , Muscle, Skeletal/physiology , Physical Conditioning, Animal/methods , Physical Endurance/physiology , Protein Kinases/metabolism , AMP-Activated Protein Kinase Kinases , Animals , Electric Stimulation , Enzyme Activation , Male , Muscle, Skeletal/innervation , Phosphorylation , Rats , Rats, Sprague-Dawley , Rest/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...