1.
Rev Sci Instrum ; 82(3): 033103, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21456714

ABSTRACT

An optical cell is described for high-throughput backscattering Raman spectroscopic measurements of hydrogen storage materials at pressures up to 10 MPa and temperatures up to 823 K. High throughput is obtained by employing a 60 mm diameter × 9 mm thick sapphire window, with a corresponding 50 mm diameter unobstructed optical aperture. To reproducibly seal this relatively large window to the cell body at elevated temperatures and pressures, a gold o-ring is employed. The sample holder-to-window distance is adjustable, making this cell design compatible with optical measurement systems incorporating lenses of significantly different focal lengths, e.g., microscope objectives and single element lenses. For combinatorial investigations, up to 19 individual powder samples can be loaded into the optical cell at one time. This cell design is also compatible with thin-film samples. To demonstrate the capabilities of the cell, in situ measurements of the Ca(BH(4))(2) and nano-LiBH(4)-LiNH(2)-MgH(2) hydrogen storage systems at elevated temperatures and pressures are reported.

2.
Appl Spectrosc ; 61(7): 694-700, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17697462

ABSTRACT

The relative intensity correction of Raman spectra requires the measurement of a source of known relative irradiance. Raman spectrometers that employ two-dimensional charge-coupled device (CCD) array detectors may be operated in two distinct modes. One mode directly measures the counts in each CCD pixel, but more commonly for the collection of spectra, the counts in the CCD row pixels are summed for a given column. If distortions in the corrected spectral shapes are to be avoided, operation in the mode where rows are summed places restrictions on the spatial intensity profile of the source of known irradiance that is used for the relative intensity correction procedure and, in some cases, also on the spatial intensity profile of the measured Raman light. Numerical expressions are given from which these restrictions can be derived. Magnitudes of distortions that can arise when intensity-correcting spectra obtained with CCD data where rows in a column are summed are estimated by modeling different cases. Data are given showing the inherent pixel quantum efficiency variation that exists in CCDs. Spectra are given showing the effects of a local area of significant change in pixel quantum efficiency that was found to be present on one CCD detector.

3.
Appl Spectrosc ; 61(2): 117-29, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17331302

ABSTRACT

Standard Reference Materials SRMs 2241 through 2243 are certified spectroscopic standards intended for the correction of the relative intensity of Raman spectra obtained with instruments employing laser excitation wavelengths of 785 nm, 532 nm, or 488 nm/514.5 nm. These SRMs each consist of an optical glass that emits a broadband luminescence spectrum when illuminated with the Raman excitation laser. The shape of the luminescence spectrum is described by a polynomial expression that relates the relative spectral intensity to the Raman shift with units in wavenumber (cm(-1)). This polynomial, together with a measurement of the luminescence spectrum of the standard, can be used to determine the spectral intensity-response correction, which is unique to each Raman system. The resulting instrument intensity-response correction may then be used to obtain Raman spectra that are corrected for a number of, but not all, instrument-dependent artifacts. Peak area ratios of the intensity-corrected Raman spectrum of cyclohexane are presented as an example of a methodology to validate the spectral intensity calibration process and to illustrate variations that can occur in this measurement.

4.
J Res Natl Inst Stand Technol ; 95(1): 33-47, 1990.
Article in English | MEDLINE | ID: mdl-28179756

ABSTRACT

Diatomic gas molecules have a fundamental vibrational motion whose frequency is affected by pressure in a simple way. In addition, these molecules have well defined rotational energy levels whose populations provide a reliable measure of the thermodynamic temperature. Since information concerning the frequency of vibration and the relative populations can be determined by laser spectroscopy, the gas molecules themselves can serve as sensors of pressure and temperature. Through measurements under static conditions, the pressure and temperature dependence of the spectra of selected molecules is now understood. As the time required for the spectroscopic measurement can be reduced to nanoseconds, the diatomic gas molecule is an excellent candidate for a dynamic pressure/temperature primary standard. The temporal response in this case will be limited by the equilibration time for the molecules to respond to changes in local thermodynamic variables. Preliminary feasibility studies suggest that by using coherent anti-Stokes Raman spectroscopy we will be able to measure dynamic pressure up to 108 Pa and dynamic temperature up to 1500 K with an uncertainty of 5%.