Anal Chem ; 89(24): 13089-13096, 2017 12 19.
Article in English | MEDLINE | ID: mdl-29116757

ABSTRACT

Seven synthesized G-lignin oligomer model compounds (ranging in size from dimers to an octamer) with 5-5 and/or ß-O-4 linkages, and three synthesized S-lignin model compounds (a dimer, trimer, and tetramer) with ß-O-4 linkages, were evaporated and deprotonated using negative-ion mode ESI in a linear quadrupole ion trap/Fourier transform ion cyclotron resonance mass spectrometer. The collision-activated dissociation (CAD) fragmentation patterns (obtained in MS2 and MS3 experiments, respectively) for the negative ions were studied to develop a procedure for sequencing unknown lignin oligomers. On the basis of the observed fragmentation patterns, the measured elemental compositions of the most abundant fragment ions, and quantum chemical calculations, the most important reaction pathways and likely mechanisms were delineated. Many of these reactions occur via charge-remote fragmentation mechanisms. Deprotonated compounds with only ß-O-4 linkages, or both 5-5 and ß-O-4 linkages, showed major 1,2-eliminations of neutral compounds containing one, two, or three aromatic rings. The most likely mechanisms for these reactions are charge-remote Maccoll and retro-ene eliminations resulting in the cleavage of a ß-O-4 linkage. Facile losses of H2O and CH2O were also observed for all deprotonated model compounds, which involve a previously published charge-driven mechanism. Characteristic "ion groups" and "key ions" were identified that, when combined with their CAD products (MS3 experiments), can be used to sequence unknown oligomers.

2.
Anal Chem ; 85(22): 10927-34, 2013 Nov 19.
Article in English | MEDLINE | ID: mdl-24098979

ABSTRACT

Mass spectrometric methodology was developed for the determination and manipulation of the primary products of fast pyrolysis of carbohydrates. To determine the true primary pyrolysis products, a very fast heating pyroprobe was coupled to a linear quadrupole ion trap mass spectrometer through a custom-built adaptor. A home-built flow tube that simulates pyrolysis reactor conditions was used to examine the secondary reactions of the primary products. Depending on the experiment, the pyrolysis products were either evaporated and quenched or allowed to react for a period of time. The quenched products were ionized in an atmospheric pressure chemical ionization (APCI) source infused with one of two ionization reagents, chloroform or ammonium hydroxide, to aid in ionization. During APCI in negative ion mode, chloroform produces chloride anions that are known to readily add to carbohydrates with little bias and little to no fragmentation. On the other hand, in positive ion mode APCI, ammonium hydroxide forms ammonium adducts with carbohydrates with little to no fragmentation. The latter method ionizes compounds that are not readily ionized upon negative ion mode APCI, such as furan derivatives. Six model compounds were studied to verify the ability of the ionization methods to ionize known pyrolysis products: glycolaldehyde, hydroxyacetone, furfural, 5-hydroxymethylfurfural, levoglucosan, and cellobiosan. The method was then used to examine fast pyrolysis of cellobiose. The primary fast pyrolysis products were determined to consist of only a handful of compounds that quickly polymerize to form anhydro-oligosaccharides when allowed to react at high temperatures for an extended period of time.

3.
Anal Chem ; 85(12): 5720-6, 2013 Jun 18.
Article in English | MEDLINE | ID: mdl-23679898

ABSTRACT

Laser-induced acoustic desorption (LIAD) was recently coupled to atmospheric pressure chemical ionization (APCI) and shown to be of great utility for the analysis of a variety of thermally labile nonpolar analytes that are not amenable to ionization via electrospray ionization, such as nonvolatile hydrocarbons. Despite these advancements, LIAD still suffered from several limitations, including only being able to sample a small fraction of the analyte molecules deposited on a Ti foil for desorption, poor reproducibility, as well as limited laser power throughput to the backside of the foil. These limitations severely hinder the analysis of especially challenging analytes, such as asphaltenes. To address these issues, a novel high-throughput LIAD probe and an assembly for raster sampling of a LIAD foil were designed, constructed, and tested. The new probe design allows 98% of the initial laser power to be realized at the backside of the foil over the 25% achieved previously, thus improving reproducibility and allowing for the analysis of large nonvolatile analytes, including asphaltenes. The raster assembly provided a 5.7 fold increase in the surface area of a LIAD foil that could be sampled and improved reproducibility and sensitivity for LIAD experiments. The raster assembly can also improve throughput as foils containing multiple analytes can be prepared and analyzed.