Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
ISA Trans ; 150: 388-403, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38782641

ABSTRACT

The increasing integration of intermittent renewable sources (RSs) poses a dynamic frequency stability challenge for modern marine vessel microgrids. To address this issue, this paper proposes a novel control approach, specifically targeting frequency and tie-line power stabilization in a diverse source marine microgrid (MµG) with two intertied areas featuring renewable (wind-wave) sources. The suggested approach introduces a modified tilt-integral active disturbance rejection (TI-ADRC) controller designed to ensure effective damping of power frequency oscillations. As the control scheme depends on the optimal setting of the proposed controller, a recently developed marine predator technique (MPT) has been adopted. The performance of the proposed controller is compared with other recent controllers viz. PID, tilt-integral derivative (TID), two-degree-of-freedom (2DOF)-PID, fuzzy-PI, and ADRC to validate its superiority. To further enhance the system dynamics, a precise modeling of inertia emulated direct current (IEPDC) tie link is incorporated in microgrid system. The impact assessments, considering time delays with pre/post IEPDC link, demonstrate a substantial 57.79% and 81.53% reduction in peak frequency overshoot compared to DC link (conventional model) and AC link, respectively. The analysis of the eigen plot confirms the stability of the control system. Sensitivity assessments of the controller against ± 30% parametric variations and load fluctuations are conducted, affirming its robustness. Finally, the result from OPAL-RT confirm the practicality of the proposed method. It is asserted that the suggested controller is reliable and functions well in n the presence of diverse disruptions and parametric variations.

2.
Sci Rep ; 13(1): 1857, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36725897

ABSTRACT

IEC 61850 is emerging as a popular communication standard for smart grids. Standardized communication in smart grids has an unwanted consequence of higher vulnerability to cyber-attacks. Attackers exploit the standardized semantics of the communication protocols to launch different types of attacks such as false data injection (FDI) attacks. Hence, there is a need to develop a cybersecurity testbed and novel mitigation strategies to study the impact of attacks and mitigate them. This paper presents a testbed and methodology to simulate FDI attacks on IEC 61850 standard compliant Generic Object-Oriented Substation Events (GOOSE) protocol using real time digital simulator (RTDS) together with open-source tools such as Snort and Wireshark. Furthermore, a novel hybrid cybersecurity solution by the name of sequence content resolver is proposed to counter such attacks on the GOOSE protocol in smart grids. Utilizing the developed testbed FDI attacks in the form of replay and masquerade attacks on are launched and the impact of attacks on electrical side is studied. Finally, the proposed hybrid cybersecurity solution is implemented with the developed testbed and its effectiveness is demonstrated.

SELECTION OF CITATIONS
SEARCH DETAIL
...