Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 16(3)2023 Jan 18.
Article in English | MEDLINE | ID: mdl-36769932

ABSTRACT

The shielding and spectroscopic properties of Pr+3 and Pr3+/Ho3+-codoped tellurite glass were investigated. The intensity parameters (Ω2 = 3.24-, Ω4 = 1.64-, Ω6 = 1.10 × 10-20 cm2) as well as the radiative lifetimes of 3F4 + 5S2 and 5I6 excited states of Ho3+ ions were equal to 301 µs and 3.0 µs, respectively. The former value appears to be much higher than that obtained from the lifetime measurement, indicating the presence of various energy transfer processes. The NIR spectrum of Pr3+/Ho3+-co-doped tellurite glass is dominated by strong Ho3+: 5I6 emission at around 1200 nm, being the result of the energy transfer from Pr3+ to Ho3+ ions. The shielding effectiveness of the prepared glasses showed good performance against high-energy photons. These findings suggest that the prepared glasses could be used in laser technology such as photodynamic therapy (PDT) treatment procedures and as shielding for radiation protection.

2.
Materials (Basel) ; 15(19)2022 Sep 20.
Article in English | MEDLINE | ID: mdl-36233860

ABSTRACT

In the optical energy gap, visible and near-IR emission of halide phosphate glasses with a composition of 40P2O5-30ZnO-20LiCl-10BaF2 in mol% doped with 3.5 × 104 ppm Pr2O3, referred to as PZLBPr, were synthesized. The UV-VIS-NIR and spectroscopic properties of these glasses were also predicted. The current glasses had broadband emission photoluminescence covering a wavelength range of 1250 to 1700 nm when excited at 455 nm. These bands for near-infrared emission luminescence relate to the transitions 1G4 → 3H5, 1D2 → 1G4, and 3H4 → 3F3, 3F4 in the optical telecommunication window. The significant PL emission wideband was caused by the radiative transition from Pr3+: 1D2 to 1G4. At 445 nm excitation, these glasses exhibited emission bands that corresponded to blue/reddish orange spectral ranges in visible ranges. The prepared glass has a high lasing quality factor (Ω4/Ω6 = 0.9), high optical energy (4.72 eV), and quantum efficiency = 87.3% with FWHM = 156 nm of transition emission from the 1D2 → 1G4 level. As a result, broadband near infrared optical amplifiers can be fabricated from the prepared glasses.

3.
Materials (Basel) ; 15(9)2022 Apr 27.
Article in English | MEDLINE | ID: mdl-35591504

ABSTRACT

In this study, the X-ray and gamma attenuation characteristics and optical properties of a synthesized tellurite-phosphate-sodium oxide glass system with a composition of (85 - x)TeO2-10P2O5-xNa2O mol% (where x = 15, 20, and 25) were evaluated. The glass systems we re fabricated by our research group using quenching melt fabrication. The shielding parameters of as-synthesized systems, such as the mass attenuation coefficient (MAC), linear attenuation coefficient (LAC), effective atomic number (Zeff), half-value layer (HVL), tenth value layer (TVL), mean free path (MFP), and effective electron density (Neff) in a wide energy range between 15 keV and 15 MeV, were estimated using well-known PHY-X/PSD software and recently developed MIKE software. Herein, the optical parameters of prepared glasses, such as molar volume (VM), oxygen molar volume (VO), oxygen packing density (OPD), molar polarizability (αm), molar refractivity (Rm), reflection loss (RL), and metallization (M), were estimated using MIKE software. Furthermore, the shielding performance of the prepared glasses was compared with that of commonly used standard glass shielding materials. The results show that the incorporation of sodium oxide into the matrix TeO2/P2O5 with an optimum concentration can yield a glass system with good shielding performance as well as good optical and physical properties, especially at low photon energy.

4.
Materials (Basel) ; 15(7)2022 Mar 24.
Article in English | MEDLINE | ID: mdl-35407736

ABSTRACT

The synthesized glass system with a composition of (80-x) TeO2-10P2O5-10Nb2O5-xKCl mol% (where x = 5, 10, 15, 20, and 25) was successfully fabricated. The density (ρ) and molar volume (Vm) have been calculated. The investigated glasses were characterized using different analysis methods (differential thermal analysis (DTA) and UV-VIS-NIR spectroscopy). The radiation shielding effectiveness of the synthesized glass system was evaluated using different shielding parameters, such as mass and linear attenuation coefficients (MAC, LAC), half-value layer (HVL), mean free path (MFP), effective atomic number (Zeff), and effective electron number (Neff). The results showed that with the increasing potassium chloride (KCl) concentration and decreasing tellurium oxide (TeO2) concentration, the density, refractive index, Urbach energy (Eu), and glass transition temperature (Tg) decreased, while the optical energy gap (Eopt) and thermal stability increased. As the KCl concentration increases, the values of MAC, LAC, and Zeff increase in the following order: TPNK5 % > TPNK10 % > TPNK15 % > TPNK20 % > TPNK25 %. Additionally, the shielding effectiveness of TPNK glass system showed good performance compared with some standard materials. The synthesized glass with a minimum KCl content has both good shielding effectiveness and good optical properties, in addition to reasonable thermal stability, which makes it suitable for shielding and optical applications.

5.
Materials (Basel) ; 15(5)2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35269073

ABSTRACT

Novel glass samples with the composition 75TeO2-5Ta2O5-15Nb2O5-5x (where x = ZnO, MgO, TiO2, or Na2O) in mole percent were prepared. The physical, optical, and gamma radiation shielding properties of the glass samples were studied over a wide energy spectrum ranging between 0.015 and 20 MeV. The glasses' UV-vis spectra were utilized to evaluate the optical energy gap and refractive index. Glass samples had a refractive index ranging from 2.2005 to 2.0967. The results showed that the sample doped with zinc oxide (ZnO) recorded the highest density (ρglass), molar polarizability (αm), molar refraction (Rm), refractive index (n), and third-order nonlinear optical susceptibility (χ3) and the lowest optical energy gap (Eopt) among the samples under investigation. When comparing the current glass system with various standard glass shielding materials, the prepared glass system showed superior shielding performance at energies ranging between 40 and 85 keV. These findings indicate that the prepared glass systems can be used in diagnostic X-rays, especially in dental applications.

6.
J Xray Sci Technol ; 30(2): 293-305, 2022.
Article in English | MEDLINE | ID: mdl-34974448

ABSTRACT

Shielding glass materials doped with heavy metal oxides show an improvement in the effectiveness of the materials used in radiation shielding. In this work, the photon shielding parameters of six tellurite glass systems doped with several metal oxides namely, 70TeO2-10P2O5- 10ZnO- 5.0PbF2- 0.0024Er2O3- 5.0X (where X represents different doped metail oxides namely, Nb2O5, TiO2, WO3, PbO, Bi2O3, and CdO) in a broad energy spectrum, ranging from 0.015 MeV to 15 MeV, were evaluated. The shielding parameters were calculated using the online software Phy-X/PSD. The highest linear and mass attenuation coefficients recorded were obtaibed from the samples containing bismuth oxide (Bi2O3), and the lowest half-value layer and mean free path were recorded among the other samples. Furthermore, the shielding effectiveness of tellurite glass systems was compared with commercial shielding materials (RS-369, RS-253 G18, chromite, ferrite, magnetite, and barite). The optical parameters viz, dispersion energy, single-oscillator energy, molar refraction, electronic polarizability, non-linear refractive indices, n2, and third-order susceptibility were measured and reported at a different wavelength. Bi2O3 has a strong effect on enhancing the optical and shielding properties. The outcome of this study suggests the potential of using the proposed glass samples as radiation-shielding materials for a broad range of imaging and therapeutic applications.


Subject(s)
Glass , Radiation Protection , Oxides , Photons , Tellurium
7.
J Xray Sci Technol ; 29(2): 331-345, 2021.
Article in English | MEDLINE | ID: mdl-33579888

ABSTRACT

BACKGROUND: Metal oxide glass composites have attracted huge interest as promising shielding materials to replace toxic, heavy, and costly conventional shielding materials. OBJECTIVE: In this work, we evaluate shielding effectiveness of four novel tellurite-based glasses samples doped with oxide metals (namely, A, B, C, and D, which are 75TeO2- 10P2O5- 10ZnO- 5PbF2- 0.24Er2O3 ; 70TeO2- 10P2O5- 10ZnO- 5PbF2 -5MgO- 0.24Er2O3; 70TeO2- 10P2O5- 10ZnO- 5PbF2- 5BaO- 0.24Er2O3 ; and 70TeO2- 10P2O5-10ZnO- 5PbF2- 5SrO; respectively) by assessing them through a wide range of ionizing radiation energies (0.015-15 MeV). METHODS: The radiation-shielding parameters including mass attenuation coefficient (MAC), linear attenuation coefficient (LAC), half-value layer (HVL), mean free path, (MFP), effective atomic number (Zeff), effective electron number (Neff), and the transmission factor are computed in the selected range of ionizing radiation energies. Furthermore, the proposed samples were compared with the most common shielding glass materials. The optical parameters viz oscillator, dispersion energy, nonlinear refractive indices, molar, and electronic polarizability of these transparent glasses are reported at different wavelengths. RESULTS: The results show that the proposed samples have considerable effectiveness as transparent shielding glass materials at various ionizing radiation energies. They can be employed for effective radiation-protection outcomes. Sample C demonstrated slightly better shielding properties than the other samples with differences of 1.33%, 4.6%, and 4.2% for samples A, B, and D, respectively. A similar trend is observed regarding the mass attenuation coefficients. Nevertheless, sample B shows better optical properties than the other prepared glass samples. CONCLUSIONS: Our findings indicate that the proposed novel glass samples have good shielding properties and optical characteristics, which can pave the way for their utilization as transparent radiation-shielding materials in medical and industrial applications.


Subject(s)
Radiation Protection , Gamma Rays , Oxides , Radiography , X-Rays
8.
J Xray Sci Technol ; 28(6): 1025-1035, 2020.
Article in English | MEDLINE | ID: mdl-32986646

ABSTRACT

BACKGROUND: Computed Tomographic (CT) imaging procedures have been reported as the main source of radiation in diagnostic procedures compared to other modalities. To provide the optimal quality of CT images at the minimum radiation risk to the patient, periodic inspections and calibration tests for CT equipment are required. These tests involve a series of measurements that are time consuming and may require specific skills and highly-trained personnel. OBJECTIVE: This study aims to develop a new computational tool to estimate the dose of CT radiation outputs and assist in the calibration of CT scanners. It may also provide an educational resource by which radiological practitioners can learn the influence of technique factors on both patient radiation dose and the produced image quality. METHODS: The computational tool was developed using MATLAB in order to estimate the CT radiation dose parameters for different technique factors. The CT radiation dose parameters were estimated from the calibrated energy spectrum of the x-ray tube for a CT scanner. RESULTS: The estimated dose parameters and the measured values utilising an Adult CT Head Dose Phantom showed linear correlations for different tube voltages (80 kVp, 100 kVp, 120 kVp, and 140 kVp), with R2 nearly equal to 1 (0.99). The maximum differences between the estimated and measured CTDIvol were under 5 %. For 80 kVp and low tube currents (50 mA, 100 mA), the maximum differences were under 10%. CONCLUSIONS: The prototyped computational model provides a tool for the simulation of a machine-specific spectrum and CT dose parameters using a single dose measurement.


Subject(s)
Decision Making, Computer-Assisted , Phantoms, Imaging , Radiation Dosage , Tomography, X-Ray Computed/methods , Adult , Head/diagnostic imaging , Humans
9.
Saudi Med J ; 27(10): 1483-8, 2006 Oct.
Article in English | MEDLINE | ID: mdl-17013468

ABSTRACT

OBJECTIVE: This project was designed to evaluate the effects of melatonin and zinc on the glycemic control in type 2 diabetes mellitus (T2DM) patients with inadequate response to the oral hypoglycemic agent metformin. METHODS: A placebo controlled, double-blind clinical trial was performed at the Specialized Center for Endocrinology and Diabetes, Al-Rusafa Directorate of Health, Baghdad, Iraq during the period from February to July 2005, in which 46 type 2 diabetic patients were selected and allocated into 3 groups, these groups were treated with single daily oral doses of both 10 mg melatonin and 50 mg zinc acetate alone; 10 mg melatonin and 50 mg zinc acetate in addition to the regularly used metformin or placebo, given at bed time for 90 days. We measured the fasting plasma glucose (FPG), glycated hemoglobin (HbA1C) and serum C-peptide before starting the treatment (zero time) and after 30 and 90 days of treatment. We also performed post-prandial glucose excursion test (PPGE) for selected patients from the second and third groups before starting the treatment and after 90 days. RESULTS: Daily administration of melatonin and zinc improved the impaired fasting and post-prandial glycemic control and decreased the level of glycated hemoglobin; addition of this treatment regimen in combination with metformin improved the tissue responses to this oral hypoglycemic agent. CONCLUSION: The combination of melatonin and zinc acetate, when used alone or in combination with metformin improves fasting and post-prandial glycemic control in T2DM patients.


Subject(s)
Antioxidants/therapeutic use , Diabetes Mellitus, Type 2/drug therapy , Glycated Hemoglobin , Melatonin/therapeutic use , Zinc Acetate/therapeutic use , Adult , Antioxidants/administration & dosage , Diabetes Mellitus, Type 2/blood , Double-Blind Method , Female , Humans , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/therapeutic use , Iraq , Male , Melatonin/administration & dosage , Metformin/administration & dosage , Metformin/therapeutic use , Middle Aged , Zinc Acetate/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...