Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Heliyon ; 9(11): e20932, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37885712

ABSTRACT

Scientific backgrounds: Development of nanostructured biodegradable alloys has generated a great deal of interest in the recent years as they offer promising bioactive materials for reconstruction of bony defects following traumatic fractures or surgical excision of tumors. Objectives: The aim of the current study was to investigate the biocompatibility of Iron-Manganese -based alloys (Fe-Mn) with addition of copper (Cu), Tungsten (W) and cobalt (Co) to obtain 3 different alloys namely, Fe-Mn-Cu, Fe-Mn-W, and Fe-Mn-Co on normal oral epithelial cell line,and their possible anticancer effect on MG-63: osteosarcoma cell line. Materials and methods: The sulforhodamine B (SRB) assay was used to assess cell viability percentage of both cell lines after exposure to discs of the proposed experimental alloys. Moreover, the antibacterial effect of such alloys against Escherichia coli (E. coli) was tested using disc diffusion susceptibility (Kirby-Bauer method) and colony suspension method. Results: The cell viability percentage of oral epithelial cell line showed a significant increase in all the experimental groups in comparison to the control group. The highest percentage was observed in Fe-Mn-Co group, followed by Fe-Mn-W then Fe-Mn-Cu, at 24 and 72-h intervals, respectively. While the cell viability percentage of osteosarcoma cell line showed significant increase in all the experimental groups at 24-h intervals, it showed a significant drop in all the study groups at 72-h intervals. The lowest percentage was observed in Fe-Mn-Cu group, followed by Fe-Mn-W then Fe-Mn-Co. Moreover, all the examined study groups didn't show any inhibition zones against E. coli reference culture. Conclusions: The novel nanostructured biodegradable Fe-Mn-Cu, Fe-Mn-W, and Fe-Mn-Co metal alloys exhibit good biocompatibility on oral epithelial cell lines with the enhancement of cell proliferation in a time-dependent manner that favors bone regeneration. On the other hand, all the alloys manifested possible anticancer activity against MG-63: osteosarcoma cell line. Furthermore, our study sheds the light on the importance of Co, W and Cu as promising alloying elements. However, the antibacterial activity of the examined alloys is still questionable. Clinical relevance: The novel nanostructured biodegradable Fe-Mn-Cu, Fe-Mn-W, and Fe-Mn-Co metal alloys offer promising bioactive materials for reconstruction of bony defects following traumatic fractures or surgical excision of tumors, In addition, they could be excellent alternatives for undegradable or non-resorbable alloys that are commonly used. Moreover, they could be used as beneficial 3D printing materials to obtain patient-specific medical implants that favor bone regeneration in addition to manufacturing of plates and screws suitable for fracture fixation.

2.
J Adv Prosthodont ; 14(3): 150-161, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35855318

ABSTRACT

PURPOSE: The purpose of the study was to assess the influence of build orientations and density of support structures on the trueness of the 3D printed removable partial denture (RPD) frameworks. MATERIALS AND METHODS: A maxillary Kennedy class III and mandibular class I casts were 3D scanned and used to design and produce two 3D virtual models of RPD frameworks. Using digital light processing (DLP) 3D printing, 47 RPD frameworks were fabricated at 3 different build orientations (100, 135 and 150-degree angles) and 2 support structure densities. All frameworks were scanned and 3D compared to the original virtual RPD models by metrology software to check 3D deviations quantitatively and qualitatively. The accuracy data were statistically analyzed using one-way ANOVA for build orientation comparison and independent sample t-test for structure density comparison at (α = .05). Points study analysis targeting RPD components and representative color maps were also studied. RESULTS: The build orientation of 135-degree angle of the maxillary frameworks showed the lowest deviation at the clasp arms of tooth 26 of the 135-degree angle group. The mandibular frameworks with 150-degree angle build orientation showed the least deviation at the rest on tooth 44 and the arm of the I-bar clasp of tooth 45. No significant difference was seen between different support structure densities. CONCLUSION: Build orientation had an influence on the accuracy of the frameworks, especially at a 135-degree angle of maxillary design and 150-degree of mandibular design. The difference in the support's density structure revealed no considerable effect on the accuracy.

3.
Materials (Basel) ; 15(6)2022 Mar 21.
Article in English | MEDLINE | ID: mdl-35329767

ABSTRACT

The optimal three-dimensional (3D) printing parameters of removable partial denture (RPD) frameworks should be studied to achieve the best accuracy, printing time, and least materials consumed. This study aimed to find the best build angle and support structures' diameter of the 3D printed (RPD) framework. Sixty (RPD) frameworks (10 in each group) were manufactured by digital light processing (DLP) 3D printing technology at three build angles (110-D, 135-D, and 150-D) and two support structures diameters (thick, L, and thin, S). Six groups were named according to their printing setting as (110-DS, 135-DS, 150-DS, 110-DL, 135-DL, and 150-DL). Frameworks were 3D scanned and compared to the original cast surface using 3D metrology software (Geomagic Control X; 3D Systems, Rock Hill, SC). Both printing time and material consumption were also recorded. Data were tested for the significant difference by one-way analysis of variance (ANOVA) test at (α = 0.05). The correlations between outcome parameters were also calculated. The 110-DL group showed the least accuracy. Significantly, the printing time of the 150-D groups had the lowest time. Material consumption of group 110-DS presented the lowest significantly statistical value. Printing time had a linear correlation with both accuracy and material consumption. Within the study limitations, the 150-degree build angle and thin diameter support structures showed optimal accuracy and time-saving regardless of material consumption.

SELECTION OF CITATIONS
SEARCH DETAIL
...