1.
Food Chem ; 187: 391-7, 2015 Nov 15.
Article in English | MEDLINE | ID: mdl-25977042

ABSTRACT

A rapid method for the determination of 14 types of isoflavones in food using ultra-high performance liquid chromatography (UHPLC) was validated in terms of precision, accuracy, sensitivity and linearity. The UHPLC separation was performed on a reverse-phase C18 column (particle size 2 µm, i.d. 2 mm, length 100 mm) using a photo diode array detector that was fixed to 260 nm. The limits of detection and quantification of the UHPLC analyses ranged from 0.03 to 0.33 mg kg(-1). The intra-day and inter-day precision of the individual isoflavones were less than 11.77% and calibration curves exhibited good linearity (r(2) = 0.99) within the tested ranges. These results suggest that the rapid method used in this study could be available to determine of 14 types of isoflavones in a variety of food such as soy bean, black bean, red bean and soybean paste.


Subject(s)
Chromatography, High Pressure Liquid/methods , Food Analysis/methods , Glycine max/chemistry , Isoflavones/analysis , Soy Foods/analysis , Isoflavones/chemistry , Limit of Detection , Reproducibility of Results , Time Factors
2.
Anal Sci ; 27(9): 873-8, 2011.
Article in English | MEDLINE | ID: mdl-21908914

ABSTRACT

An automated dynamic headspace sampler coupled to a gas chromatograph/mass spectrometer was evaluated as an oxidative marker to determine hexanal content in vegetable oils. For the effective analysis, a cooled injection system (CIS) was used to focus and to introduce the hexanal desorbed from the Tenax TA. The temperature of the CIS was maintained at -60 °C for 12 min before desorbing the hexanal. Hexanal was separated on a capillary column (DB-5, 0.25 mm × 60 m, 0.25 µm in film thickness) from 50 to 230 °C, followed by mass spectrometer-selected ion monitoring analysis at m/z 56. The instrumental response to hexanal was highly linear from 10 ng mL(-1) to 1 µg mL(-1) (r(2) = 0.9999). The relative standard deviation (RSD) of intra- and inter-day repeatability was acceptable, with values of less than 3.88 and 4.25%, respectively. The LOD and LOQ of hexanal were determined by gas chromatograph/mass spectrometer-selected ion monitoring to be 3.3 and 9.8 ng mL(-1), respectively. The acid value, peroxide value and fatty acid composition revealed a good correlation with the hexanal concentration.


Subject(s)
Aldehydes/analysis , Automation, Laboratory/methods , Food Analysis/methods , Gas Chromatography-Mass Spectrometry/methods , Plant Oils/chemistry , Plant Oils/classification , Reproducibility of Results , Sensitivity and Specificity , Temperature , Time Factors