As one of the effective control devices of air pollutants, the wet electrostatic precipitator (ESP) is an effective technique to eliminate acid mist and fine particles that are re-entrained in a collection electrode. However, its collection efficiency can deteriorate, as its operation is subject to water-induced corrosion of the collection electrode. To overcome this drawback, we modified the wet ESP system with the installation of a PVC dust precipitator wherein water is supplied as a replacement of the collection electrode. With this modification, we were able to construct a compact wet ESP with a small specific collection area (SCA, 0.83 m(2)/(m(3)/min)) that can acquire a high collection efficiency of fine particles (99.7%).


Subject(s)
Air Pollution/prevention & control , Chemical Precipitation , Particulate Matter/analysis , Water/chemistry , Air Pollutants/analysis , Air Pollutants/chemistry , Corrosion , Electrodes , Electrowetting/methods , Equipment Design/methods , Particle Size , Particulate Matter/chemistry , Polyvinyl Chloride/chemistry , Static Electricity , Water Supply/analysis , Wetting Agents/chemistry