Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 22(8)2022 Apr 09.
Article in English | MEDLINE | ID: mdl-35458867

ABSTRACT

In indoor localization there are applications in which the orientation of the agent to be located is as important as knowing the position. In this paper we present the results of the orientation estimation from a local positioning system based on position-sensitive device (PSD) sensors and the visible light emitted from the illumination of the room in which it is located. The orientation estimation will require that the PSD sensor receives signal from either 2 or 4 light sources simultaneously. As will be shown in the article, the error determining the rotation angle of the agent with the on-board sensor is less than 0.2 degrees for two emitters. On the other hand, by using 4 light sources the three Euler rotation angles are determined, with mean errors in the measurements smaller than 0.35° for the x- and y-axis and 0.16° for the z-axis. The accuracy of the measurement has been evaluated experimentally in a 2.5 m-high ceiling room over an area of 2.2 m2 using geodetic measurement tools to establish the reference ground truth values.

2.
Sensors (Basel) ; 21(11)2021 Jun 07.
Article in English | MEDLINE | ID: mdl-34200221

ABSTRACT

Reduced deployment and calibration requirements are key for scalable and cost-effective indoor positioning systems. In this work, we propose a low-complexity, weak calibration procedure for an indoor positioning system based on infrastructure lighting and a positioning-sensitive detector. The proposed calibration relies on genetic algorithms to obtain the relevant system parameters in the real positioning environment without a priori information, and requires a low number of simple measurements. The achievable performance of the proposal was assessed by direct comparison with a formal offline calibration method requiring complex dedicated infrastructure and instruments. The comparative error assessment showed that the maximum accuracy reduction compared to the significantly more costly formal calibration was below 25 mm, and the overall absolute positioning error was smaller than 35 mm with orientation errors of around 0.25°. The performance achieved with the proposed weak calibration procedure is sufficient for many indoor positioning applications and largely reduces the cost and complexity of setting up the positioning system in real environments.

SELECTION OF CITATIONS
SEARCH DETAIL
...