Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Ultrasonics ; 116: 106495, 2021 Jun 15.
Article in English | MEDLINE | ID: mdl-34186322

ABSTRACT

This work aims to describe the development and validation of two low-intensity pulsed ultrasound stimulation systems able to control the dose delivered to the biological target. Transducer characterization was performed in terms of pressure field shape and intensity, for a high-frequency range (500 kHz to 5 MHz) and for a low-frequency value (38 kHz). This allowed defining the distance, on the beam axis, at which biological samples should be placed during stimulation and to exactly know the intensity at the target. Carefully designed retaining systems were developed, for hosting biological samples. Sealing tests proved their impermeability to external contaminants. The assembly/de-assembly time of the systems resulted ~3 min. Time-domain acoustic simulations allowed to precisely estimate the ultrasound beam within the biological sample chamber, thus enabling the possibility to precisely control the pressure to be transmitted to the biological target, by modulating the transducer's input voltage. Biological in vitro tests were also carried out, demonstrating the sterility of the system and the absence of toxic and inflammatory effects on growing cells after multiple immersions in water, over seven days.

2.
Clin Neurophysiol ; 131(10): 2341-2348, 2020 10.
Article in English | MEDLINE | ID: mdl-32828036

ABSTRACT

OBJECTIVE: To study motor cortex plasticity after a period of training with a new prototype of bidirectional hand prosthesis in three left trans-radial amputees, correlating these changes with the modification of Phantom Limb Pain (PLP) in the same period. METHODS: Each subject underwent a brain motor mapping with Transcranial Magnetic Stimulation (TMS) and PLP evaluation with questionnaires during a six-month training with a prototype of bidirectional hand prosthesis. RESULTS: The baseline motor maps showed in all three amputees a smaller area of muscles representation of the amputated side compared to the intact limb. After training, there was a partial reversal of the baseline asymmetry. The two subjects affected by PLP experienced a statistically significant reduction of pain. CONCLUSIONS: Two apparently opposite findings, the invasion of the "deafferented" cortex by neighbouring areas and the "persistence" of neural structures after amputation, could vary according to different target used for measurement. Our results do not support a correlation between PLP and motor cortical changes. SIGNIFICANCE: The selection of the target and of the task is essential for studies investigating motor brain plasticity. This study boosts against a direct and unique role of motor cortical changes on PLP genesis.


Subject(s)
Amputation, Surgical , Evoked Potentials, Motor/physiology , Motor Cortex/physiopathology , Muscle, Skeletal/physiopathology , Neuronal Plasticity/physiology , Prostheses and Implants , Amputees , Brain Mapping , Female , Hand/physiopathology , Humans , Male , Middle Aged
3.
Sci Rep ; 9(1): 7916, 2019 05 27.
Article in English | MEDLINE | ID: mdl-31133637

ABSTRACT

Providing somatosensory feedback to amputees is a long-standing objective in prosthesis research. Recently, implantable neural interfaces have yielded promising results in this direction. There is now considerable evidence that the nervous system integrates redundant signals optimally, weighting each signal according to its reliability. One question of interest is whether artificial sensory feedback is combined with other sensory information in a natural manner. In this single-case study, we show that an amputee with a bidirectional prosthesis integrated artificial somatosensory feedback and blurred visual information in a statistically optimal fashion when estimating the size of a hand-held object. The patient controlled the opening and closing of the prosthetic hand through surface electromyography, and received intraneural stimulation proportional to the object's size in the ulnar nerve when closing the robotic hand on the object. The intraneural stimulation elicited a vibration sensation in the phantom hand that substituted the missing haptic feedback. This result indicates that sensory substitution based on intraneural feedback can be integrated with visual feedback and make way for a promising method to investigate multimodal integration processes.


Subject(s)
Amputees/rehabilitation , Artificial Limbs , Brain-Computer Interfaces , Feedback, Sensory/physiology , Ulnar Nerve/physiology , Electric Stimulation/instrumentation , Electric Stimulation/methods , Electrodes, Implanted , Electromyography , Female , Forearm/innervation , Forearm/physiology , Humans , Middle Aged , Single-Case Studies as Topic , Treatment Outcome
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 1039-1043, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31946071

ABSTRACT

Skeletal muscle differentiation was proven to be influenced by changes in the substrate stiffness. However, a lack of knowledge features this field, concerning skeletal muscle tissues obtained from human induced pluripotent stem cells. Here we report the fabrication of polydimethylsiloxane-based substrates in a range of stiffness values from 3.5 to 141 kPa and the response of human induced pluripotent stem cells cultured on them for 5 days. The substrates were able to sustain cell adhesion and proliferation throughout the whole period. An inversely proportional relationship (although not significant) was found between the proliferation rate and the substrate stiffness. Initial analyses of iPSCs skeletal muscle differentiation shown no influences on markers of the early stages. These results lay the foundations for further studies on the influence of extrinsic mechanical stimuli on induced pluripotent stem cells-derived skeletal muscle tissues.


Subject(s)
Induced Pluripotent Stem Cells , Cell Adhesion , Cell Differentiation , Cells, Cultured , Humans
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 2513-2516, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31946408

ABSTRACT

This work aims to describe the design and development of an in vitro highly controlled ultrasonic stimulation system able to guarantee, at the same time, high usability and full sterility of the tested samples. After creating the first prototype of an ultrasound-transparent three-chambers culture well, sealing tests were conducted to prove its impermeability to external contaminants and in vitro tests were carried out to verify the usability of this system for ultrasonic stimulation of cells in vitro. No statistically significant differences were found between control and tested samples during sealing tests, thus demonstrating optimal sealing ability towards external contaminants. Furthermore, the thin polystyrene membrane used to guarantee US-transparency guaranteed a good adhesion and viability of both human fibroblasts and induced pluripotent stem cells.


Subject(s)
Fibroblasts/cytology , Induced Pluripotent Stem Cells/cytology , Ultrasonic Waves , Cells, Cultured , Humans
6.
Sci Rep ; 8(1): 16666, 2018 11 12.
Article in English | MEDLINE | ID: mdl-30420739

ABSTRACT

Recent studies have shown that direct nerve stimulation can be used to provide sensory feedback to hand amputees. The intensity of the elicited sensations can be modulated using the amplitude or frequency of the injected stimuli. However, a comprehensive comparison of the effects of these two encoding strategies on the amputees' ability to control a prosthesis has not been performed. In this paper, we assessed the performance of two trans-radial amputees controlling a myoelectric hand prosthesis while receiving grip force sensory feedback encoded using either linear modulation of amplitude (LAM) or linear modulation of frequency (LFM) of direct nerve stimulation (namely, bidirectional prostheses). Both subjects achieved similar and significantly above-chance performance when they were asked to exploit LAM or LFM in different tasks. The feedbacks allowed them to discriminate, during manipulation through the robotic hand, objects of different compliances and shapes or different placements on the prosthesis. Similar high performances were obtained when they were asked to apply different levels of force in a random order on a dynamometer using LAM or LFM. In contrast, only the LAM strategy allowed the subjects to continuously modulate the grip pressure on the dynamometer. Furthermore, when long-lasting trains of stimulation were delivered, LFM strategy generated a very fast adaptation phenomenon in the subjects, which caused them to stop perceiving the restored sensations. Both encoding approaches were perceived as very different from the touch feelings of the healthy limb (natural). These results suggest that the choice of specific sensory feedback encodings can have an effect on user performance while grasping. In addition, our results invite the development of new approaches to provide more natural sensory feelings to the users, which could be addressed by a more biomimetic strategy in the future.


Subject(s)
Artificial Limbs , Hand/surgery , Feedback, Sensory/physiology , Female , Hand/physiology , Humans , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...