Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
Add more filters










Publication year range
1.
BMC Chem ; 17(1): 92, 2023 Aug 02.
Article in English | MEDLINE | ID: mdl-37533125

ABSTRACT

The greenness of any analytical method has become a very important aspect of a good analytical method. However, most chromatographic methods depend on the usage of relatively large amounts of lethal and un-decaying chemicals and solvents. So, a green approach based on the full factorial design was employed to develop a simple and rapid HPLC technique for concurrent determination of paracetamol and dantrolene sodium in their combined capsules. Both drugs are highly recommended to be administered together in patients with severe musculoskeletal disorders. Avoiding the routine methodology and resorting to the modern technology represented in the usage of experimental design allows rapid determination of the studied drugs using the optimum quantity of chemicals to avoid any waste of resources. Simultaneous separation of a binary mixture of paracetamol and dantrolene sodium was accomplished using a reversed phase Hypersil C18 column using an eco-friendly isocratic eluent. The used mobile phase consisted simply of ethanol: water (40:60, v/v). Orthophosphoric acid was used to adjust the pH of the mobile phase to 4.5. Triethanolamine (0.2%) was added aiming to reduce the peak tailing. The assay was completed within less than 6 min adopting 0.8 mL/min as a flow rate. The detection was carried out using a UV-detector at 290 nm. The suggested technique shows a linear correlation over concentration ranges of 1.0-200 and 1.0-40 µg/mL for paracetamol and dantrolene sodium, respectively. The suggested technique allowed the simultaneous analysis of the two co-formulated drugs in their synthetic mixture and combined capsule. The suggested technique is considered a greener substitute for the other reported HPLC techniques through the usage of safer solvents and chemicals, along with decreasing both waste output and analysis time. The method is accurate with recoveries between 97.85 and 101.27%, precise, as %RSD for the intraday and interday precision were between 0.39 and 1.72% and very sensitive with limits of detection (LOD)'s 0.15 and 0.18 µg/ml and limits of quantification (LOQ)'s 0.48 and 0.61 µg/ml for paracetamol and dantrolene sodium, respectively. The method greenness was ensured through its assessment by four greenness metrics. It is also validated following the International Conference on Harmonization Guidelines. The recommended technique could be a good alternative to traditional methods in the routine quality control analysis of the studied drugs due to its minimum harm to the planet or human beings.

2.
Spectrochim Acta A Mol Biomol Spectrosc ; 296: 122670, 2023 Aug 05.
Article in English | MEDLINE | ID: mdl-37019003

ABSTRACT

Recently, Chemometric calibration methods in spectrophotometric analysis are achieving significant attention in the quality control of resolving drug mixtures and pharmaceutical formulations containing two or more drugs with overlapping spectra. The simple univariate methods have been used over the last few decades and has proven to be highly efficient and easy to apply. In this study, a comparative study was performed between some univariate and multivariate methods to determine if chemometric methods can substitute univariate methods in pharmaceutical analysis. In this study, three chemometric techniques were compared to seven univariate techniques to resolve a mixture of mefenamic acid and febuxostat in their raw materials, dosage forms and spiked human plasma. Mefenamic acid and febuxostat were used together for treatment of gout. The applied chemometric methods are partial least squares (PLS), artificial neural network (ANN) and genetic algorithm partial least squares (GA-PLS), while the used univariate methods include first derivative, second derivative, ratio spectra, derivative ratio spectra, ratio subtraction, Q-Absorbance ratio and mean centering spectrophotometric methods. The ten proposed methods were found to be green, sensitive, and rapid. They are simple and did not require any pre-separation steps. The results of both univariate and multivariate approaches were statistically compared with the reported spectrophotometric methods using student's t test and ratio variance F-test. They were also compared with each other, using one-way analysis of variance (ANOVA). These methods were assessed and validated according to ICH guidelines. The studied drugs were analyzed in their pharmaceutical dosage forms and spiked human plasma with good recoveries using the developed methods, which qualify them for routine quality control of the studied drugs.


Subject(s)
Febuxostat , Mefenamic Acid , Humans , Spectrophotometry/methods , Analysis of Variance , Least-Squares Analysis , Pharmaceutical Preparations
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 295: 122626, 2023 Jul 05.
Article in English | MEDLINE | ID: mdl-36940537

ABSTRACT

In this work, a label-free, rapid, and sensitive synchronous spectrofluorometric method was implemented to assay atenolol (ATL) and ivabradine hydrochloride (IVB) in pharmaceutical and biological matrices. Simultaneous determination of ATL and IVB by conventional spectrofluorometry cannot be implemented because of the clear overlap of the emmision spectra of ATL and IVB. To overcome this problem, synchronous fluorescence measurements at a constant wavelength difference (Δλ) combined with mathematical derivatization of the zero order spectra were perforemed. The results indicated a good resolution between emission spectra of the studied drugs when the first-order derivative of the synchronous fluorescence scans at Δλ = 40 nm was conducted using ethanol as the optimum solvent which is less hazardous than other organic solvents such as methanol and acetonitrile, keeping the method safe and green. The amplitudes of the first derivative synchronous fluorescent scans of ATL and IVB in ethanol were monitored at 286 and 270 nm to simultaneously estimate ATL and IVB, respectively. Method optimisation was conducted by assessing different solvents, buffer pHs, and surfactants. The optimum results were obtained when ethanol was utilized as a solvent without using any other additives. The developed method was linear over concentration ranges of 10.0-250.0 ng mL-1 for IVB and 100.0-800.0 ng mL-1 for ATL with detection limits of 3.07 and 26.49 ng mL-1 for IVB and ATL, respectively. The method was utilized to assay the studied drugs in their dosages and in human urine samples with acceptable % recoveries and RSD values. The greenness of the method was implemented by three approaches involving the recently reported metric (AGREE) which ensured the eco-freindship and safety of the method.


Subject(s)
Atenolol , Ethanol , Humans , Ivabradine , Solvents , Spectrometry, Fluorescence/methods , Pharmaceutical Preparations
4.
BMC Chem ; 17(1): 19, 2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36922850

ABSTRACT

BACKGROUND: Cardiovascular disease medications such as aspirin (ASP), statins like atorvastatin (ATR), and blood pressure-lowering drugs including ACE inhibitors like ramipril (RAM) have been included in the World Health Organization (WHO) Essential Medicines List (EML) for many years. Therefore, there is a strong demand to develop a simple, rapid, and sensitive analytical method that can detect and quantitate the ternary mixture of these analytes in pharmaceutical preparations in a short run time. Lately, the analytical community focused on eliminating or reducing hazardous chemicals and solvents usage. RESULTS: A green, fast, selective, and cost-effective micellar HPLC method was established and validated for the concurrent determination of ternary combination of ASP, ATR, and RAM in the pure form and pharmaceutical preparations. Resolution of the three drugs was achieved by using a monolithic column and a micellar mobile phase consists of 0.3% triethylamine (TEA) in 90: 10 an aqueous solution of 0.12 M sodium dodecyl sulfate (SDS): n-propanol, (v/v). The pH was adjusted to 2.5 using orthophosphoric acid and a flow rate of 1.5 mL/min. was applied. To ensure method reproducibility, Valsartan (VAL) was utilized as an internal standard (IS). The UV detection of the studied drugs was performed at 210 nm. Good linearity for the three drugs was obtained over the concentration ranges of 1.0-200.0 mg/mL, 0.5-200.0 mg/mL, and 5.0-100.0 mg/mL with correlation coefficients of 0.9998,0.9999 and 0.9999 for ASP, ATR, and RAM respectively. The method sensitivity was revealed by the relatively small values of limits of detection (LOD) (0.19, 0.13 and 0.30 mg/mL) and limits of quantitation (LOQ) (0.63, 0.44 and 0.99 mg/mL) for ASP, ATR, and RAM, respectively. The retention times of ASP, ATR and RAM were 1.50, 2.3 and 4.3 min., respectively. CONCLUSIONS: The suggested technique was employed for the analysis of the three drugs in their prepared tablets maintaining the recommended pharmaceutical ratio without any interference from excipients. The method was further extended to content uniformity testing of RAM. The results were validated according to international council for harmonisation (ICH) guidelines.

5.
Sci Rep ; 13(1): 4237, 2023 03 14.
Article in English | MEDLINE | ID: mdl-36918612

ABSTRACT

The non-steroidal anti-inflammatory medication acemetacin was assessed via two straightforward green spectrofluorimetric techniques. The quenching-dependent derivatizing spectrofluorimetric reactions are the master point of this study. Acriflavine-based method (Method I) depends on forming an ion association complex between acriflavine and the drug in a ratio of 1:1, decreasing the former's fluorescence intensity. Acriflavine or Ag NP's intensity-related quenching action goes linearly with the acemetacin concentration in the 2.0-20.0 µg/mL and 1.0-16.0 µg/mL ranges, respectively. The second quenching mechanism depends on using the silver nanoparticles (Ag NP's) as a fluorescence probe (Method II); Ag NP's were prepared from reducing silver nitrate using sodium borohydride. Both methods could be applied to determine pure and pharmaceutical dosage forms of acemetacin. The methods proved valid according to the international conference on harmonization (ICH) guidelines. In addition to this, this work has been estimated under green criteria assessment tools. There is no significant difference between the proposed and the comparison methods after the statistical interpretation.


Subject(s)
Acriflavine , Metal Nanoparticles , Acriflavine/pharmacology , Fluorescent Dyes , Spectrometry, Fluorescence/methods , Silver
6.
Spectrochim Acta A Mol Biomol Spectrosc ; 295: 122573, 2023 Jul 05.
Article in English | MEDLINE | ID: mdl-36921519

ABSTRACT

Four accurate, green, uncomplicated, and fast spectrophotometric procedures were established for the purpose of resolving as well as quantifying a ternary combination prescribed for cardiovascular patients, such as aspirin, atorvastatin, and ramipril. Method (A) is based on the first derivative zero-crossing spectrophotometry for the determination of aspirin and atorvastatin at 247.4 nm and 302.6 nm, respectively. Ramipril was determined using the second derivative at 211 nm. Method (B) depends on the ratio spectra first derivative (RDS) where the absorption spectrum of the ternary combination was divided by the spectrum of one of the analytes. When treated similarly, the concentrations of the other two analytes were measured using their corresponding calibration graphs. For the determination of ASP and RAM, ATR was used as a divisor with a concentration of 26 µg/mL, and the RDS values at 272.0 and 225.8 nm, respectively, were plotted against the ASP and RAM concentrations. Using 40 µg/mL ASP as a divisor, ATR was analyzed, and the RDS values at 295 nm were plotted versus the ATR concentration. Method (C) is based on the double divisor-ratio spectra derivative technique. In this technique, the derivative of the ratio spectrum is computed by dividing the absorption spectra of the studied combination by the standard spectrum of abinary combination of two of the three analytes being studied. The concentrations of the three analytes in the mixture were assayed by determining the absorbance either at the positive or the negative amplitude. For the determination of ASP, ATR, and RAM, the wavelengths used were 244, 295, and 220 nm, respectively. Method (D) was a hybrid double divisor-ratio spectra technique based on convolving the double divisor-ratio spectra with trigonometric Fourier functions. The magnitudes of the Fourier function coefficients at either maximum or minimum points were correlated to the concentration of each drug in the mixture. The specificity of the suggested methods was tested by analyzing synthetic laboratory-prepared combinations and laboratory-made tablets. Furthermore, the accuracy and precision were ensured by statistically comparing the obtained results with those obtained from comparison method using Bartlett's Test for Equality of Variances and ANOVA test.


Subject(s)
Cardiovascular Agents , Humans , Ramipril , Atorvastatin , Spectrophotometry/methods , Aspirin
7.
J Fluoresc ; 33(4): 1661-1671, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36809413

ABSTRACT

Lower back pain is a universal dilemma leaving a negative effect on both health and life quality. It was found that a fixed dose combination of chlorzoxazone and ibuprofen gave a higher efficiency than analgesic alone in treatment of acute lower back pain. Based on the significant benefit of that combination, a green, sensitive, rapid, direct, and cost-effective method is created for concurrent determination of ibuprofen and chlorzoxazone in presence of 2-amino para chlorophenol (a synthetic precursor and potential impurity of chlorzoxazone) adopting the synchronous spectrofluorimetric technique. Synchronous spectrofluorimetric technique is adopted to avoid the highly overlapped native spectra of both drugs. The synchronous spectrofluorometric method was applied at Δλ = 50 nm, ibuprofen was measured at 227 nm while chlorzoxazone was measured at 282 nm with no hindering from one to another. The various experimental variables affecting the performance of the suggested technique were explored and adjusted. The suggested technique showed good linearity from 0.02 to 0.6 and 0.1 to 5.0 µg/mL for ibuprofen and chlorzoxazone, respectively. The produced detection limits were 0.27 × 10-3 and 0.03, while the quantitation limits were 0.82 × 10-3 and 0.09 µg/mL for ibuprofen and chlorzoxazone, respectively. The suggested approach was successfully applied for the analysis of the studied drugs in the synthetic mixture, different pharmaceutical preparations, and spiked human plasma. The suggested technique was validated with respect to the International Council of Harmonization (ICH) recommendations. The suggested technique was found to be simpler and greener with lower cost compared to the earlier reported methods which required complicated techniques, longer time of analysis, and less safe solvents and reagents. Green profile assessment for the developed method compared with the reported spectrofluorometric method was performed using four assessment tools. These tools confirmed that the recommended technique attained the most possible green parameters, so it could be used as a greener option in routine quality control for analyzing the two drugs in genuine form and pharmaceutical preparations.


Subject(s)
Ibuprofen , Low Back Pain , Humans , Chlorzoxazone/analysis , Fluorescence , Pharmaceutical Preparations , Spectrometry, Fluorescence/methods
8.
Sci Rep ; 13(1): 1616, 2023 01 28.
Article in English | MEDLINE | ID: mdl-36709387

ABSTRACT

An optimization approach based on full factorial design was employed for developing an HPLC-UV method for simultaneous determination of a quaternary mixture used for the treatment of symptoms related to common cold and COVID-19. The quaternary mixture is composed of paracetamol, levocetirizine dihydrochloride, phenylephrine hydrochloride and ambroxol hydrochloride. The developed technique is a green, fast and simple method that uses isocratic elution of mobile phase consisting of 20:5:75 (v/v) of ethanol: acetonitrile: 2.5 mM heptane-1-sulphonic acid sodium salt at pH 6.5 [Formula: see text] 0.02. The chromatographic separation was carried out using Hypersil BDS Cyano LC Column (250 × 4.6 mm, 5 µm) with 230 nm UV detection and 1.0 mL/min. flow rate. Avoiding the routine methodology and resorting to the modern technology-represented in the usage of experimental design-allows rapid determination of the four drugs using the optimum quantity of chemicals to avoid any waste of resources. The quaternary mixture was eluted in less than 9 min., where retention times of paracetamol, levocetirizine dihydrochloride, phenylephrine hydrochloride and ambroxol hydrochloride were found to be 2.2, 3.8, 6.6 and 8.8 min., respectively. The calibration graphs of the four drugs were linear over concentration ranges of 50.0-500.0, 0.5-20.0, 0.5-20.0 and 0.5-100.0 µg/mL for paracetamol, levocetirizine dihydrochloride, phenylephrine hydrochloride and ambroxol hydrochloride, respectively with correlation coefficients higher than 0.999. The method is accurate with mean recoveries between 99.87 and 100.04%, precise, as %RSD for the intraday and interday precision were between 0.61 and 1.64% and very sensitive with limit of detections (LOD)'s between 29 and 147 ng/mL and limit of quantification (LOQ)'s between 95 and 485 ng/mL. The proposed method was successfully applied for the analysis of the four drugs either in raw materials or in prepared tablet with the least amount of chemicals within short time. It is also validated following International Conference on Harmonization Guidelines. The proposed method was found to be green according to the most common greenness assessment tools; NEMI, GAPI, Analytical Eco-Scale and AGREE methods. The advantages of the proposed method qualify it for routine analysis of the studied drugs either in single or co-formulated dosage form in quality control labs.


Subject(s)
Ambroxol , COVID-19 , Common Cold , Humans , Chromatography, High Pressure Liquid/methods , Acetaminophen , Phenylephrine/chemistry
9.
Spectrochim Acta A Mol Biomol Spectrosc ; 291: 122336, 2023 Apr 15.
Article in English | MEDLINE | ID: mdl-36680834

ABSTRACT

Drug-pepsin interaction possibly affects pepsin activity, leads to undesirable shift of its functionality, and likely induces adverse effects in the gastrointestinal tract. The present study aims at exploring the interaction of pepsin with the antiprotozoal/antibacterial drug secnidazole adopting a combination of experimental spectroscopy and computational techniques. For this purpose, different spectroscopic methods including fluorescence, synchronous fluorescence, UV-Visible absorption, and infrared spectroscopy were adopted and coordinated with in silico analysis via molecular docking. The employed synchronized approaches evidenced that; pepsin interacted with secnidazole via static mechanism at stomach pH inferring some consequent conformational changes in the structure of pepsin. Thermodynamic study of drug-pepsin interaction demonstrated that the interaction is spontaneous via van der Waals and hydrogen bonding interaction and the orientation of ligand within pepsin cavity was illustrated by molecular docking. The synchronous fluorescence study proved that tyrosine amino acid residues were involved in the interaction more than tryptophan amino acid residues. Eventually, the combined experimental and molecular docking approaches suggest that secnidazole interacts with pepsin and alter its structure, that finding correlates to gastrointestinal side effects related to secnidazole oral administration.


Subject(s)
Anti-Infective Agents , Pepsin A , Pepsin A/chemistry , Binding Sites , Spectrometry, Fluorescence , Molecular Docking Simulation , Thermodynamics , Anti-Infective Agents/pharmacology , Amino Acids , Perception , Protein Binding , Circular Dichroism
10.
Spectrochim Acta A Mol Biomol Spectrosc ; 289: 122074, 2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36508901

ABSTRACT

A new, rapid, selective, green, and highly sensitive method has been established to determine ivabradine and carvedilol simultaneously. The first derivative synchronous spectrofluorimetric approach was applied for the determination of the studied drugs. Assessment of the first derivative amplitude of carvedilol and ivabradine has been done at 339 nm and 298 nm respectively which are the zero crossing points of each other. The method validation is estimated and was found to be consistent with International Conference on Harmonization guidelines. Linearity was found to be in the range of 10.0 to 90.0 ng/mL for carvedilol and from 80.0 to140.0 ng/mL for ivabradine. The detection limits were found to be 1.2 ng/ mL and 3.3 ng/mL and the quantitation limits were 3.7 ng / mL and 10.0 ng /mL for carvedilol and ivabradine, respectively. The method was effectively applied for the determination of both drugs in their synthetic mixture in different ratios and in their prepared co-formulated tablets. The results were compared with those of comparison HPLC methods. Ethanol was used as a green solvent. The proposed method is suitable for the determination of ivabradine and carvedilol with satisfactory accuracy and precision. The greenness of the method was evaluated using four assessment tools, i.e. NEMI, GAPI, Eco-scale, and AGREE. The proposed method is simple with a low cost compared to HPLC methods.


Subject(s)
Carvedilol , Ivabradine , Spectrometry, Fluorescence/methods , Solvents , Tablets
11.
RSC Adv ; 12(52): 33540-33551, 2022 Nov 22.
Article in English | MEDLINE | ID: mdl-36505685

ABSTRACT

A green, quick and sensitive spectrofluorimetric technique was investigated and validated for the assay of three different drugs namely, ketoprofen (KPN), paracetamol (PAR), and chlorzoxazone (CLX). The method is based on fluorescence quenching of the fluorescence probe, silver nanoparticles (SNPs). The fluorescence quenching of SNPs may be attributed to the complexation between each of the studied drugs with SNPs. The fluorescence of SNPs alone or after complexation with the studied drugs were measured at 485 nm (λ ex 242 nm) without the need to extract the formed complex. Chemical reduction was employed for preparing SNPs, where silver nitrate was reduced by sodium borohydride in deionized water without adding organic stabilizer. SNPs were found soluble in water, had high stability and had a narrow emission band. The studied drugs were found to decrease the fluorescence of SNPs significantly through static quenching according to Stern-Volmer equation. Factors affecting the reaction between the drugs and NPs were carefully examined and optimized. Using the optimum conditions, the difference in the fluorescence intensity of SNPs before and after complexation with the studied drugs was in a good linear relationship with the concentration of the studied drugs, where (R 2 = 0.9998, 0.9998 and 0.9991) in the ranges of 0.5-5.0, 0.15-3.0 and 0.5-9.0 µg mL-1 for KPN, PAR and CLX, respectively. Validity of the proposed method was investigated according to ICH recommendations. The proposed technique was also employed for the analysis of each of the three drugs in commercial or laboratory prepared tablets and in spiked human plasma with very good recoveries as well as high level of accuracy and precision. This method was intended to the analysis of the proposed drugs in their single formulation and single drug administration. The suggested technique is considered an eco-friendly method, as it uses water as the safest and least expensive solvent. Moreover, the recommended technique does not involve solvent extraction of the formed complexes. Greenness assessment of the suggested procedure was accomplished by applying the four standard assessment tools. Consequently, the recommended method can be used in the routine quality control analysis of the cited drugs with minimum harmful effect on the environment as well as the individuals.

12.
J AOAC Int ; 105(6): 1516-1527, 2022 Oct 26.
Article in English | MEDLINE | ID: mdl-35723537

ABSTRACT

BACKGROUND: Recently, quantitative nuclear magnetic resonance (qNMR) competes with separation techniques such as high performance liquid chromatography (HPLC) and capillary electrophoresis for quantification purposes when dealing with molecules that lack a chromophore. OBJECTIVE: The advantages of the proton nuclear magnetic resonance spectroscopy as a revolutionary quantitative analysis method were exploited aimed at simple and green assessment of two racetams, namely levetiracetam (LEV) and brivaracetam (BRV), as a new family of antiepileptic medications with a unique mechanism of action. The developed technique was effectively used to determine LEV in Keppra tablets and BRV in laboratory-prepared tablets without interfering with the ordinarily suspected excipients. METHOD: A Taguchi approach was applied as a powerful and user-friendly statistical technique for optimization of the qH1NMR experimental design for both drugs. The optimum acquisition conditions were number of scans 32, pulse angle 20°, and relaxation delay of 40 s for LEV and number of scans 128, pulse angle 90°, and relaxation delay of 1 s for BRV. NMR spectra were obtained by means of phloroglucinol as an internal standard and dimethyl sulfoxide-d6 as a solvent. RESULTS: The diagnostic doublet of doublet quantitative signals at 4.3 and at 4.2 ppm were chosen to estimate LEV and BRV, respectively. The recovery of both drugs was quantified through the range of 0.1-12 mg/mL. The limits of detection were 0.013, 0.0013 and the limits of quantitation were 0.04, 0.0039 mg/mL for LEV and BRV correspondingly. CONCLUSIONS: The suggested technique was fully validated according to ICH guidelines and proved to be an eco-friendly practice by means of three different assessment tools, including the green analytical procedures index, national environmental methods index, and analytical eco-scale. qH1NMR should be considered a green alternative for quantification and quality control assessment of pharmaceuticals. HIGHLIGHTS: This research represents the first simple, quick, and green alternative method for determination of both racetams in their pharmaceuticals.


Subject(s)
Anticonvulsants , Excipients , Levetiracetam , Anticonvulsants/pharmacology , Anticonvulsants/therapeutic use , Proton Magnetic Resonance Spectroscopy , Dimethyl Sulfoxide , Protons , Phloroglucinol , Solvents
13.
Spectrochim Acta A Mol Biomol Spectrosc ; 267(Pt 2): 120591, 2022 Feb 15.
Article in English | MEDLINE | ID: mdl-34789407

ABSTRACT

In this study, a facile, rapid, and sensitive spectrofluorimetric method was evolved to analyse two antihypertensive drugs, namely, metolazone (MTZ) and valsartan (VST), in pharmaceutical and biological matrices. Both analytes exhibited intrinsic fluorescence activities which were significantly affected by environmental factors such as pH and solvent systems. However, simultaneous determination of MTZ and VST by conventional spectrofluorometry cannot be achieved simply because of the strong overlap between their fluorescence spectra. Thus, a combination of derivative and synchronous spectrofluorometry was conducted to overcome this dilemma. The proposed method relies on measurement of the first-order derivative of synchronous fluorescence intensity of the studied drugs at Δλ = 160 nm using 0.1 M acetic acid as the optimum solvent. The amplitudes of the first derivative synchronous fluorescence spectra of MTZ and VST were recorded at 236.0 nm (zero-crossing point of VST) and at 262.8 nm (zero-crossing point of MTZ) for simultaneous analysis of MTZ and VST, respectively. The fluorescent method was optimized efficiently to get the maximum selectivity and sensitivity by investigating different solvents, different buffer pHs, and different surfactants. The highest sensitivity and selectivity were achieved when 0.1 M acetic acid was used as a solvent. The method showed a linear concentration range of 10.0-100.0 ng mL-1 and a limit of detection of <3.0 ng mL-1 for each analyte. Statistical data analysis confirmed that no significant difference between the proposed spectrofluorometric method and the reference methods. The validity of the proposed spectrofluorometric method approved its suitability for quality control work. The proposed spectrofluorometric method was applied to assay the studied drugs in pharmaceutical dosage and in biological matrices with acceptable %recoveries and small RSD values.


Subject(s)
Metolazone , Pharmaceutical Preparations , Antihypertensive Agents , Spectrometry, Fluorescence , Valsartan
14.
R Soc Open Sci ; 8(7): 210562, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34295531

ABSTRACT

Green analysis has turned out to be of a great value in all areas, including pharmaceutical analysis. Thus, it is extremely important to consider the environmental influence of each step in developing any analysis technique. The present work illustrates a validated, simple and green spectrofluorimetric method for the analysis of dantrolene sodium (DAN). The developed process is characterized by being of high sensitivity as well as being relatively inexpensive. The suggested technique based on the formation of a highly fluorescent product of DAN via its reduction by the aid of Zn/HCl system. The resulting fluorophore showed a powerful fluorescence at λ em 344 nm after excitation at λ ex 279 nm. Calibration graph revealed a great linear regression (r = 0.9998) within concentration ranging from 0.05 to 2.0 µg ml-1. The suggested method had very low detection and quantification limits of 0.010 and 0.031 µg ml-1, respectively. The applied technique was effectively used in the determination of DAN in its pharmaceutical preparations. The results were compared with those from using the official United States Pharmacopeia (USP) method and they were in a good agreement. Moreover, content uniformity testing of DAN in capsules was performed adopting the investigated technique with satisfying results. The greenness of the suggested technique was confirmed by the three standard assessment tools. Therefore, the developed technique can be used in the routine quality control analysis of DAN with minimum harmful impact on nature or individuals.

15.
Luminescence ; 33(8): 1423-1431, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30362232

ABSTRACT

Sensitive, simple and specific spectrophotometric and spectrofluorimetric methods were developed for the determination of triamterene in bulk powder and pharmaceutical dosage form. The spectrophotometric method (Method A) is based on the formation of an ion-pair complex with eosin Y in acetate buffered solution of pH 3.7 followed by measuring the absorbance at 545 nm. The absorbance-concentration plot is rectilinear over the range 3.0-15.0 µg/mL with a limit of detection (LOD) of 0.429 µg/mL and a limit of quantitation (LOQ) of 1.031 µg/mL. The spectrofluorimetric method (Method B) is based on the reaction of triamterene with 7- chloro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) in basic solution (pH 10) to form a product with high fluorescence measured at 546 nm after being excited at 438 nm. The plot of fluorescence versus concentration is linear within the range 2.0-10.0 µg/mL. The suggested methods were applied for the analysis of commercial capsules containing the studied drug with successful results. The results obtained from the proposed method were statistically compared with those of a reported one and revealed good agreement. The presented methods are useful in routine analysis of triamterene in laboratories of quality control.


Subject(s)
Triamterene/analysis , Capsules/chemistry , Molecular Structure , Powders/chemistry , Spectrometry, Fluorescence , Spectrophotometry
16.
Environ Sci Pollut Res Int ; 24(30): 23880-23892, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28871503

ABSTRACT

Gemifloxacin (GEM) is a broad-spectrum quinolone antibiotic. The presence of GEM residuals in industrial and hospital wastewater has been associated with genotoxicity and antibiotic resistance. In this contribution, the photodegradation of GEM using titanium dioxide nanoparticles (TiO2NPs)/H2O2 as a catalyst was optimized to eliminate residual drug and its photodegradates with antibacterial activity. A half-factorial design was implemented, investigating the effects of pH, initial concentration, H2O2 concentration, TiO2NP loading, and irradiation time. Owing to the time-dependent, multi-transformation of GEM into a wide range of structurally related photodegradation products, the monitoring of GEM throughout the experiments was achieved using both HPLC and potentiometric ion-selective electrodes (ISE). The sensor enabled in-line tracking of residual GEM in the presence of its photodegradates in real time. Results indicated that the pH, irradiation time, and GEM initial concentration were the most significant factors. At the optimum set of experimental conditions, the reaction followed first-order reaction kinetics with a mean percentage degradation of ~ 95% in less than 30 min of irradiation time and almost complete loss of antibacterial activity against Escherichia coli. The promising results demonstrated the efficiency of UV/TiO2NP/H2O2 as a photocatalyst for the breakdown of the pharmacophore of fluoroquinolones from water samples. The high selectivity, minimal solvent consumption, and lack of harmful waste generation confirmed the superiority of in-line monitoring using ISE. Optimization and in-line monitoring protocol should be applicable also at the pharmaceutical industry scale to eliminate the risk of antibiotic resistance.


Subject(s)
Fluoroquinolones/pharmacokinetics , Hydrogen Peroxide/chemistry , Naphthyridines/pharmacokinetics , Titanium/chemistry , Wastewater/chemistry , Catalysis , Fluoroquinolones/chemistry , Gemifloxacin , Hydrogen-Ion Concentration , Kinetics , Nanoparticles , Naphthyridines/chemistry , Photolysis , Water Pollutants, Chemical/analysis
17.
Bioanalysis ; 9(14): 1049-1064, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28737428

ABSTRACT

AIM: Antiepileptics (AEDs) and antipsychotics are often coprescribed. Interactions between these drugs may affect both efficacy and toxicity. Therefore, drug monitoring is necessary for appropriate dosage adjustments. MATERIALS & METHODS: Specific 'turn-on' chemosensor, 4-chloro-7-nitrobenzofurazan is used for selective and sensitive determination of two AEDs: zonisamide (ZON) and topiramate (TOP) with the antipsychotic sulpiride (SUL) in epileptic patients' plasma followed by reversed-phase-HPLC separation without any interference. RESULTS: Linear behavior was observed in the range of 0.1-3 µg/ml and 0.01-0.5 µg/ml for the AEDs and SUL, respectively, with LOD of 33, 46 and 4 ng/ml and LOQ of 86, 93 and 9 ng/ml for ZON, TOP and SUL, respectively. The proposed method was successfully applied for determination of different pharmacokinetic parameters of ZON and TOP, and for clinical monitoring of the three drugs in healthy volunteers following oral administration. CONCLUSION: The developed method is suitable for the routine therapeutic drug monitoring of these drugs.


Subject(s)
Anticonvulsants/blood , Blood Chemical Analysis/methods , Chromatography, High Pressure Liquid/methods , Spectrometry, Fluorescence/instrumentation , Adult , Anticonvulsants/pharmacokinetics , Epilepsy/blood , Female , Fructose/analogs & derivatives , Fructose/blood , Fructose/pharmacokinetics , Humans , Hydrogen-Ion Concentration , Isoxazoles/blood , Isoxazoles/pharmacokinetics , Limit of Detection , Linear Models , Male , Sulpiride/blood , Sulpiride/pharmacokinetics , Time Factors , Topiramate , Water/chemistry , Zonisamide
18.
Luminescence ; 32(4): 555-563, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27753197

ABSTRACT

Three different spectrophotometric and two spectrofluorimetric methods have been developed and validated for the determination of vincamine (VN) and naftidrofuryl oxalate (NF) in tablets. The spectrophotometric methods depend on charge transfer complex formation between each of VN and NF with 7,7,8,8-tetracyano-quinodimethane (TCNQ), 2,6-dichloroquinone-4-chloroimide (DCQ) and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) at 843, 580 and 588 nm, respectively. The spectrofluorimetric methods are based on the formation of charge transfer complex between each of the two drugs and TCNQ, with measurement of the fluorophore formed at 312/375 and 284/612 nm, respectively, or with DDQ at 400/475 and 284/396 nm, respectively. In the spectrophotometric measurements, Beer's law was obeyed at concentration ranges of 1.5-16, 10-180 and 12-140 µg/ml for VN with TCNQ, DCQ, and DDQ, respectively. For NF, the corresponding concentrations were 2-28, 5-75 and 25-150 µg/ml with TCNQ, DCQ, and DDQ, respectively. In the spectrofluorimetric measurements, the ranges for VN were 0.05-0.9 and 0.3-4 µg/ml with TCNQ and DDQ, respectively, whereas for NF the ranges were 0.05-0.85 and 0.5-8 µg/ml with TCNQ and DDQ, respectively. The different experimental parameters affecting the development and stability of the formed color or fluorophore were studied and optimized and the molar ratios of the complexes were calculated. The proposed methods were validated according to ICH guidelines and were successfully applied for the determination of VN and NF in their tablet dosage forms.


Subject(s)
Benzoquinones/chemistry , Imines/chemistry , Nafronyl/analysis , Nitriles/chemistry , Spectrometry, Fluorescence/methods , Vincamine/analysis , Capsules/analysis , Limit of Detection , Nafronyl/chemistry , Reproducibility of Results , Tablets/analysis , Temperature , Vincamine/chemistry
19.
Bioanalysis ; 8(21): 2219-2234, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27678163

ABSTRACT

AIM: Recently, polytherapy regimen has been introduced for the treatment of epileptic patients for better seizure control with lesser side effects and better control of multiple seizure types. METHODOLOGY: A simple, sensitive and highly specific reversed-phase HPLC method was developed for simultaneous determination of four antiepileptic drugs (AEDs), levetiracetam, lamotrigine, oxcarbazepine and carbamazepine, in real human plasma without interference from endogenous components of plasma. CONCLUSION: The method was proved to be linear in the range of 0.5-50 µg/ml for all drugs. It was successfully applied for clinical PK study of the AEDs in healthy volunteers following single administration. Also, this method was applied for simultaneous determination of the studied drugs in volunteers' plasma receiving synergistic binary combinations from the four AEDs when used as add-on therapy. The good precision and selectivity of the developed method allow it to be used for routine therapeutic drug monitoring of such drugs as a useful tool in epilepsy management.


Subject(s)
Anticonvulsants/blood , Blood Chemical Analysis/methods , Chromatography, High Pressure Liquid , Anticonvulsants/pharmacokinetics , Anticonvulsants/standards , Calibration , Carbamazepine/analogs & derivatives , Carbamazepine/blood , Carbamazepine/pharmacokinetics , Carbamazepine/standards , Chromatography, High Pressure Liquid/standards , Half-Life , Humans , Lamotrigine , Levetiracetam , Limit of Detection , Oxcarbazepine , Piracetam/analogs & derivatives , Piracetam/blood , Piracetam/pharmacokinetics , Piracetam/standards , Triazines/blood , Triazines/pharmacokinetics , Triazines/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...