Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J Robot Surg ; 17(6): 2875-2880, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37804395

ABSTRACT

While robotic-assisted surgery (RAS) has been revolutionizing surgical procedures, it has various areas needing improvement, specifically in the visualization sector. Suboptimal vision due to lens occlusions has been a topic of concern in laparoscopic surgery but has not received much attention in robotic surgery. This study is one of the first to explore and quantify the degree of disruption encountered due to poor robotic visualization at a major academic center. In case observations across 28 RAS procedures in various specialties, any lens occlusions or "debris" events that appeared on the monitor displays and clinicians' reactions, the cause, and the location across the monitor for these events were recorded. Data were then assessed for any trends using analysis as described below. From around 44.33 h of RAS observation time, 163 debris events were recorded. 52.53% of case observation time was spent under a compromised visual field. In a subset of 15 cases, about 2.24% of the average observation time was spent cleaning the lens. Additionally, cautery was found to be the primary cause of lens occlusions and little variation was found within the spread of the debris across the monitor display. This study illustrates that in 6 (21.43%) of the cases, 90% of the observation time was spent under compromised visualization while only 2 (7.14%) of the cases had no debris or cleaning events. Additionally, we observed that cleaning the lens can be troublesome during the procedure, interrupting the operating room flow.


Subject(s)
Laparoscopy , Robotic Surgical Procedures , Robotics , Humans , Robotic Surgical Procedures/methods , Operating Rooms , Laparoscopy/methods
2.
J Robot Surg ; 17(3): 915-922, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36342614

ABSTRACT

Despite major technological advancements in robotic-assisted laparoscopic surgery (RAS), there remain shortcomings yet to be addressed. This study assesses the prevalence of suboptimal vision in minimally invasive RAS and corresponding factors regarding related surgical conditions. 45 minimally invasive robotic surgeries, performed using Da Vinci XI, were observed across three surgical subspecialties: general, urology, and OB/GYN. Lens occlusion events were monitored and defined as the presence of a visual distortion caused by debris deposition on the scope lens. Lens occlusions and cleanings, and "active instrumentation" were recorded. Descriptive statistics summarized duration-based variables, and one-factor ANOVA compared the presence of active instrumentation. Cases averaged 127 ± 76 min. Active instrumentation ANOVA during lens occlusions demonstrated significant variation between categories (F7, 256 = 11.63, p = 2.558e-13). Post hoc Tukey HSD found electrocautery devices were active significantly more during occlusion events (37.9%) than other instruments. On average, lens cleaning occurred every 36.5 ± 39.8 min despite lens occlusion occurring every 24.5 ± 15.7 min. Of the operative time observed, 41.4% ± 28.1% was conducted with visual distortion. 1.16% ± 0.97% of time observed was spent cleaning. Although only 1.16% of operative time was spent cleaning, surgeons experienced suboptimal conditions for nearly 35× the time it would take the clear lens, potentially indicating a tendency to avoid cleaning the lens to disrupt surgery. Future research may examine the impact of occluded visualization and lens cleaning on other aspects of surgery.


Subject(s)
Laparoscopy , Robotic Surgical Procedures , Robotics , Humans , Robotic Surgical Procedures/methods , Minimally Invasive Surgical Procedures , Operative Time
3.
JSLS ; 26(4)2022.
Article in English | MEDLINE | ID: mdl-36721732

ABSTRACT

Background: A frequently encountered problem in laparoscopic surgery is an impaired visual field. The Novel Intracavitary Laparoscopic Cleaning Device (NILCD) is designed to adequately clean a laparoscopic lens quickly and efficiently without requiring removal from the surgical cavity. Animal and cadaver studies showed good efficacy and a short learning curve. This study aims to describe the efficacy and initial human experience with the device during laparoscopic operations. Methods: Since 2020, NILCD was used in 167 cases with surgeons at 12 different institutions in Texas, California, and Massachusetts. The rate of scope removal in each case was examined. Following each trial, users were asked to rank the NILCD on ease of set up, insertion, adjustment, and cleaning efficacy. A survey was then used to evaluate surgeon satisfaction. Results: The NILCD was tested in a variety of cases, including colorectal, gynecological, general, pediatric, hepatobiliary, thoracic, bariatric and foregut surgery. NILCD usage eliminated the need for scope removal in 90.14% of debris events, with only 97 removals in 984 events. Eighty-six percent of users reported that the NILCD improved their visual field. When asked to rate specific qualities of the device using a 5-point Likert scale, surgeons gave an average score of 4.56 for ease of setup, 4.10 for ease of insertion, and 4.12 for ease of adjusting and cleaning efficacy. Conclusion: In an initial analysis of 167 cases, the NILCD proved to be an effective and convenient method of cleaning the laparoscopic lens in-vivo. It was associated with good surgeon satisfaction.


Subject(s)
Gynecology , Laparoscopy , Lenses , Surgeons , Animals , Humans , Child , Learning Curve
4.
Surg Endosc ; 35(1): 493-501, 2021 01.
Article in English | MEDLINE | ID: mdl-32974779

ABSTRACT

BACKGROUND: Viral particles have been shown to aerosolize into insufflated gas during laparoscopic surgery. In the operating room, this potentially exposes personnel to aerosolized viruses as well as carcinogens. In light of circumstances surrounding COVID-19 and a concern for the safety of healthcare professionals, our study seeks to quantify the volumes of gas leaked from dynamic interactions between laparoscopic instruments and the trocar port to better understand potential exposure to surgically aerosolized particles. METHODS: A custom setup was constructed to simulate an insufflated laparoscopic surgical cavity. Two surgical instrument use scenarios were examined to observe and quantify opportunities for insufflation gas leakage. Both scenarios considered multiple configurations of instrument and trocar port sizes/dimensions: (1) the full insertion and full removal of a laparoscopic instrument from the port and (2) the movement of the scope within the port, recognized as "dynamic interaction", which occurs nearly 100% of the time over the course of any procedure. RESULTS: For a 5 mm instrument in a 5 mm trocar, the average volume of gas leaked during dynamic interaction and full insertion/removal scenarios were 43.67 and 25.97 mL of gas, respectively. Volume of gas leaked for a 5 mm instrument in a 12 mm port averaged 41.32 mL and 29.47 for dynamic interaction vs. instrument insertion and removal. Similar patterns were shown with a 10 mm instrument in 12 mm port, with 55.68 mL for the dynamic interaction and 58.59 for the instrument insertion/removal. CONCLUSIONS: Dynamic interactions and insertion/removal events between laparoscopic instruments and ports appear to contribute to consistent leakage of insufflated gas into the OR. Any measures possible taken to reduce OR gas leakage should be considered in light of the current COVID-19 pandemic. Minimizing laparoscope and instrument removal and replacement would be one strategy to mitigate gas leakage during laparoscopic surgery.


Subject(s)
COVID-19/prevention & control , Infection Control/methods , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Laparoscopy/methods , Occupational Diseases/prevention & control , Occupational Exposure/prevention & control , Personnel, Hospital , Aerosols , COVID-19/transmission , Humans , Insufflation/instrumentation , Insufflation/methods , Laparoscopy/instrumentation
5.
J Clin Endocrinol Metab ; 104(10): 4865-4878, 2019 10 01.
Article in English | MEDLINE | ID: mdl-31150063

ABSTRACT

OBJECTIVE: Cold exposure increases energy expenditure (EE) and could have a role in combating obesity. To understand this potential, we determined the capacity for cold-induced thermogenesis (CIT), the EE increase above the basal metabolic rate at the individualized coldest tolerable temperature before overt shivering. DESIGN: During a 13-day inpatient protocol, we quantitated the EE of 12 lean men and 9 men with obesity at various randomly ordered ambient temperatures in a room calorimeter. Subjects underwent brown fat imaging after exposure to their coldest tolerable temperature. RESULTS: CIT capacity was 300 ± 218 kcal/d (mean ± SD) or 17 ± 11% in lean men and 125 ± 146 kcal/d or 6 ± 7% in men with obesity (P = 0.01). The temperature below which EE increased, lower critical temperature (Tlc), was warmer in lean men than men with obesity (22.9 ± 1.2 vs 21.1 ± 1.7°C, P = 0.03), but both had similar skin temperature (Tskin) changes and coldest tolerable temperatures. Whereas lean subjects had higher brown fat activity, skeletal muscle activity increased synchronously with CIT beginning at the Tlc in both groups, indicating that muscle is recruited for CIT in parallel with brown fat, not sequentially after nonshivering thermogenesis is maximal. CONCLUSIONS: Despite greater insulation from fat, men with obesity had a narrower range of tolerable cool temperatures available for increasing EE and less capacity for CIT than lean men, likely as a result of greater basal heat production and similar perception to Tskin cooling. Further study of the reduced CIT capacity in men with obesity may inform treatment opportunities for obesity.


Subject(s)
Cold Temperature , Obesity/physiopathology , Thermogenesis/physiology , Adipose Tissue, Brown/metabolism , Adolescent , Adult , Basal Metabolism , Body Composition/physiology , Body Mass Index , Energy Metabolism/physiology , Humans , Male , Obesity/metabolism , Young Adult
6.
Lasers Surg Med ; 47(6): 495-502, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26041069

ABSTRACT

Near-infrared Spectroscopy (NIRS) is a broadly utilized technology with many emerging applications including clinical diagnostics, sports medicine, and functional neuroimaging, to name a few. For functional brain imaging NIR light is delivered at multiple wavelengths through the scalp and skull to the brain to enable spatial oximetry measurements. Dynamic changes in brain oxygenation are highly correlated with neural stimulation, activation, and function. Unfortunately, NIRS is currently limited by its low spatial resolution, shallow penetration depth, and, perhaps most importantly, signal corruption due to light interactions with superficial non-target tissues such as scalp and skull. In response to these issues, we have combined the non-invasive and rapidly reversible method of mechanical tissue optical clearing (MOC) with a commercially available NIRS system. MOC utilizes a compressive loading force on tissue, causing the lateral displacement of blood and water, while simultaneously thinning the tissue. A MOC-NIRS Breath Hold Test displayed a ∼3.5-fold decrease in the time-averaged standard deviation between channels, consequentially promoting greater channel agreement. A Skin Pinch Test was implemented to negate brain and muscle activity from affecting the recorded signal. These results displayed a 2.5-3.0 fold increase in raw signal amplitude. Existing NIRS instrumentation has been further integrated within a custom helmet device to provide a uniform force distribution across the NIRS sensor array. These results showed a gradual decrease in time-averaged standard deviation among channels with an increase in applied pressure. Through these experiments, and the development of the MOC-NIRS helmet device, MOC appears to provide enhancement of NIRS technology beyond its current limitations.


Subject(s)
Functional Neuroimaging/methods , Optical Imaging/methods , Spectroscopy, Near-Infrared/methods , Breath Holding , Functional Neuroimaging/instrumentation , Humans , Optical Imaging/instrumentation , Spectroscopy, Near-Infrared/instrumentation
7.
Cell Metab ; 19(2): 302-9, 2014 Feb 04.
Article in English | MEDLINE | ID: mdl-24506871

ABSTRACT

Rediscovery of cold-activated brown adipose tissue (BAT) in humans has boosted research interest in identifying BAT activators for metabolic benefits. Of particular interest are cytokines capable of fat browning. Irisin, derived from FNDC5, is an exercise-induced myokine that drives brown-fat-like thermogenesis in murine white fat. Here we explored whether cold exposure is an afferent signal for irisin secretion in humans and compared it with FGF21, a brown adipokine in rodents. Cold exposure increased circulating irisin and FGF21. We found an induction of irisin secretion proportional to shivering intensity, in magnitude similar to exercise-stimulated secretion. FNDC5 and/or FGF21 treatment upregulated human adipocyte brown fat gene/protein expression and thermogenesis in a depot-specific manner. These results suggest exercise-induced irisin secretion could have evolved from shivering-related muscle contraction, serving to augment brown fat thermogenesis in concert with FGF21. Irisin-mediated muscle-adipose crosstalk may represent a thermogenic, cold-activated endocrine axis that is exploitable in obesity therapeutics development.


Subject(s)
Exercise/physiology , Fibroblast Growth Factors/blood , Fibronectins/blood , Adipocytes/metabolism , Adipokines/metabolism , Adipose Tissue, Brown/metabolism , Adult , Female , Fibroblast Growth Factors/metabolism , Fibronectins/metabolism , Humans , Male , Shivering/physiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...