Arch Med Sci ; 20(2): 410-419, 2024.
Article in English | MEDLINE | ID: mdl-38757027

ABSTRACT

Introduction: Limited data exist on long-term follow-up of severe aortic stenosis (SAS) patients who have undergone transcatheter aortic valve implantation (TAVI) with a new generation, balloon expandable Myval transcatheter heart valve (THV). Thus, we sought to investigate the performance and 2-year clinical outcome of the Myval THV system based on Valve Academic Research Consortium-3 (VARC-3) criteria. Material and methods: A multi-centre, registry-based, observational study was conducted, which included 207 consecutive degenerative SAS patients, from Turkey (n = 128), Italy (n = 58), and Greece (n = 21) (mean [standard deviation] 81 (7) years, 94 [45%] men; 73% NYHA III or IV; EuroSCORE II 5.2% [2.4%]); all patients underwent TAVI with Myval. Patients were followed up at 1 year and 2 years after implantation. Clinical and procedural outcomes were defined according to VARC-3 criteria. Results: Technical success was observed in 204 (99%), device success was observed in 189 (91%), early safety was observed in 161 (78%), and clinical efficacy was observed in 163 (79%) patients. The 30-day death rate was 7.7%; of these, 3.4% were due to cardiovascular reasons. All-cause and cardiovascular mortality rates were 9.7% and 4.3% at 1-year follow-up, and 17.4% and 9.7% at 2-year follow-up, respectively. Incidence of ≥ moderate paravalvular leak (PVL) at 30 days, 1 year and 2 years of follow-up were 3.4%, 4.3% and 4.8%. A total of 11.1% of patients required a permanent pacemaker implantation (PPI) at 30 days after implantation, while the cumulative rate of PPI at 2 years was 12.1%. Conclusions: In this cohort of patients with SAS, the Myval was found to be safe and effective in up to 2 years of follow-up.

2.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

3.
Lancet ; 2024 May 22.
Article in English | MEDLINE | ID: mdl-38795719

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.

4.
Lancet ; maio.2024.
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1555077

ABSTRACT

BACKGROUND Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1•5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2­4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10•44% and assuming an event rate of 26•10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80•0 years (SD 5•7) for those treated with the Myval THV and 80•4 years (5•4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2•6% [IQR 1•7­4•0] vs contemporary 2•6% [1•7­4•0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of ­2•3% (one-sided upper 95% CI 3•8, pnon-inferiority<0•0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days.

5.
Eur J Clin Invest ; : e14209, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38597271

ABSTRACT

BACKGROUND: In the last few years, percutaneous LAA occlusion (LAAO) has become a plausible alternative in atrial fibrillation (AF) patients with contraindications to anticoagulation therapy. Nevertheless, the optimal antiplatelet strategy following percutaneous LAAO remains to be defined. METHODS: Studies comparing single antiplatelet therapy (SAPT) versus dual antiplatelet therapy (DAPT) following LAAO were systematically searched and screened. The outcomes of interest were ischemic stroke, device-related thrombus (DRT) and major bleeding. A random-effect meta-analysis was performed comparing outcomes in both groups. The moderator effect of baseline characteristics on outcomes was evaluated by univariate meta-regression analyses. RESULTS: Sixteen observational studies with 3255 patients treated with antiplatelet therapy (SAPT, n = 1033; DAPT, n = 2222) after LAAO were included. Mean age was 74.5 ± 8.3 years, mean CHA2DS2-VASc and HAS-BLED scores were 4.3 ± 1.5 and 3.2 ± 1.0, respectively. At a weighted mean follow-up of 12.7 months, the occurrence of stroke (RR 1.33; 95% CI 0.64-2.77; p =.44), DRT (RR 1.52; 95% CI 0.90-2.58; p =.12), and the composite of stroke and DRT (RR 1.26; 95% CI 0.67-2.37; p =.47) did not differ significantly between SAPT and DAPT groups. The rate of major bleedings was also not different between groups (RR 1.41; 95% CI 0.64-3.12; p =.39). CONCLUSIONS: Among AF patients at high bleeding risk undergoing percutaneous LAAO, a post-procedural minimalistic antiplatelet strategy with SAPT did not significantly differ from DAPT regimens regarding the rate of stroke, DRT and major bleeding.

6.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38538170

ABSTRACT

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Subject(s)
Aortic Valve Stenosis , Coronary Occlusion , Heart Valve Prosthesis , Lacerations , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Lacerations/complications , Lacerations/surgery , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Coronary Occlusion/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Prosthesis Design
7.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38479966

ABSTRACT

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Ischemic Stroke , Stroke , Transcatheter Aortic Valve Replacement , Humans , Ischemic Stroke/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Treatment Outcome , Stroke/diagnostic imaging , Stroke/etiology , Stroke/prevention & control , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
9.
Int J Cardiol ; 400: 131701, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38168557

ABSTRACT

BACKGROUND: The new balloon-expandable (BE) Myval transcatheter heart valves (THV) has shown promising early results with low paravalvular leak (PVL) and permanent pacemaker implantation (PPI) rates. Limited data are available regarding its long-term performance. We aimed to compare the 2-year clinical and echocardiographic outcomes of transcatheter aortic valve replacement (TAVR) using the self-expanding (SE) Evolut R and the BE Myval THVs. METHODS: The EVAL study included 166 patients with severe aortic valve stenosis who underwent TAVR either with SE Evolut R (n = 108) or BE Myval (n = 58) THV. Primary objectives include comparison on clinical efficacy (freedom from all-cause mortality, stroke, and cardiovascular hospitalization), echocardiographic performance and PPI rates between the two THVs. RESULTS: At 2-year the BE Myval group showed higher clinical efficacy (86% vs. 66%,HR:2.62, 95%CI 2.2-5.1;p = 0.006), with fewer cardiac hospitalizations (3.4% vs. 13.9%,p = 0.03). No significant differences in all-cause mortality, cardiovascular mortality, or stroke rates were observed. The proportion of patients with ≥moderate PVL was significantly lower in the BE Myval compared to the SE Evolut R group (4%vs. 22%,p = 0.008). The mean transvalvular gradient was significantly higher in the SE group compared to the BE group (9.5 ± 4.3 vs. 6.9 ± 2.2 mmHg,p < 0.001), however there was no difference in the percentage of patients with a mean gradient ≥20 mmHg between the two groups. CONCLUSIONS: Both THVs offer similar 2-year clinical outcomes. The BE Myval THV demonstrated advantages with higher clinical efficacy and lower PVL incidence. Longer follow-up and randomized trials are needed to validate these results and assess Myval's sustained performance and durability.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Prosthesis Design , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Stroke/surgery
11.
Rev Esp Cardiol (Engl Ed) ; 77(3): 215-225, 2024 Mar.
Article in English, Spanish | MEDLINE | ID: mdl-37506972

ABSTRACT

INTRODUCTION AND OBJECTIVES: After ST-segment myocardial infarction (STEMI), the impact of different adverse events on prognosis remains unknown. We aimed to assess very long-term predictors of patient-oriented composite endpoints (POCE) and investigate whether the occurrence of target vessel failure (TVF) vs a non-TVF event as the first event could potentially influence subsequent outcomes. METHODS: The EXAMINATION-EXTEND trial randomized STEMI patients to receive either an everolimus-eluting stent or a bare-metal stent. The follow-up period was 10 years. Predictors of POCE (a composite of all-cause death, any myocardial infarction, or any revascularization) were evaluated in the overall study population. The patients were stratified based on the type of first event (TVF-first vs non-TVF-first) and were compared in terms of subsequent POCE. TVF was defined as a composite of cardiac death, TV myocardial infarction, or TV revascularization. RESULTS: Out of the 1498 enrolled patients, 529 (35.3%) experienced a POCE during the 10-year follow-up. Independent predictors of POCE were age, diabetes mellitus, previous myocardial infarction, peripheral arterial disease, and multivessel coronary disease. The first event was a TVF in 296 patients and was a non-TVF in 233 patients. No significant differences were observed between TVF-first and non-TVF-first patients in terms of subsequent POCE (21.7% vs 39.3%, time ratio 1.79; 95%CI, 0.87-3.67;P=.12) or its individual components. CONCLUSIONS: At the 10-year follow-up, approximately one-third of STEMI patients had experienced at least 1 POCE. Independent predictors of these events were age, diabetes, and more extensive atherosclerotic disease. The occurrence of a TVF or a non-TVF as the first event did not seem to influence subsequent outcomes. TRIAL REGISTRATION NUMBER: NCT04462315.


Subject(s)
Diabetes Mellitus , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , Drug-Eluting Stents/adverse effects , Myocardial Infarction/diagnosis , Myocardial Infarction/epidemiology , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Prognosis , Sirolimus , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/surgery , ST Elevation Myocardial Infarction/complications , Treatment Outcome
12.
Minerva Cardiol Angiol ; 72(2): 163-171, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37705369

ABSTRACT

BACKGROUND: De novo diffuse coronary artery disease (CAD) is a challenging scenario in interventional cardiology with limited treatment option, beside stent implantation. In this context, a hybrid approach, combining the use of drug-eluting stent (DES) and drug-coated balloon (DCB) to treat different segments of the same lesion (e.g. long lesion and/or true bifurcation), might be an interesting and alternative strategy to limit the metal amount. The aim of this study was to evaluate the safety and efficacy of a hybrid approach in addressing percutaneous treatment of de novo diffuse CAD. METHODS: This was a prospective, multicenter study including patients affected by de novo diffuse CAD treated with a hybrid approach from April 2019 to December 2020. Angiographic and clinical data were collected. The primary endpoint was the one-year device-oriented composite endpoint (DOCE, cardiac death, target vessel myocardial infarction and ischemia-driven target lesion revascularization [ID-TLR]). Periprocedural myocardial infarctions and periprocedural success were included among secondary endpoints. RESULTS: One hundred six patients were included, mean age was 68.2±10.2 years and 78.3% were male. De novo diffuse CAD consisted of 52.8% long lesions and 47.2% true bifurcation lesions. Significant increase in the final minimal lumen diameters and significant decrease in the final diameter stenosis were observed when compared to the baseline values in both DES- and DCB-target segments. Procedural success was 96.2%. DOCE at one-year was 3.7%, with all the adverse events characterized by ID-TLR. CONCLUSIONS: Combination of DES and DCB could be a safe and effective treatment option for the treatment of de novo diffuse CAD (NCT03939468).


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease , Drug-Eluting Stents , Myocardial Infarction , Humans , Male , Middle Aged , Aged , Female , Coronary Artery Disease/surgery , Drug-Eluting Stents/adverse effects , Prospective Studies , Angioplasty, Balloon, Coronary/adverse effects
13.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37138103

ABSTRACT

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Treatment Outcome , Aortic Valve/surgery , Registries , Prosthesis Design
14.
Int J Cardiol ; 397: 131622, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38061607

ABSTRACT

BACKGROUND: Impact of gender on heart remodeling after acute coronary syndrome (ACS) and consequently on development of heart failure (HF) remains to be elucidated. METHODS: CORALYS is a multicenter, retrospective, observational registry enrolling consecutive patients admitted for ACS and treated with percutaneous coronary intervention. HF hospitalization was the primary endpoint while all-cause mortality and the composite endpoint of incidence of first HF hospitalization and cardiovascular mortality were the secondary ones. RESULTS: Among 14,699 patients enrolled in CORALYS registry, 4578 (31%) were women and 10,121 (69%) males. Women were older, had more frequently hypertension and diabetes and less frequently smoking habit. History of myocardial infarction (MI), STEMI at admission and multivessel disease were less common in women. After median follow up of 2.9 ± 1.8 years, women had higher incidence of primary and secondary endpoints and female sex was an independent predictor of HF hospitalization (HR 1.26;1.05-1.50; p = 0.011) and cardiovascular death/HF hospitalization (HR 1.18;1.02-1.37; p = 0.022). At multivariable analysis women and men share as predictors of HF diabetes, history of cancer, chronic kidney disease, atrial fibrillation, complete revascularization and left ventricular ejection fraction. Chronic obstructive pulmonary disease (HR 2.34;1.70-3.22, p < 0.001) and diuretics treatment (HR 1.61;1.27-2.04, p < 0.001) were predictor of HF in men, while history of previous MI (HR 1.46;1.08-1.97, p = 0.015) and treatment with inhibitors of renin-angiotensin system (HR 0.69;0,49-0.96 all 95% CI, p = 0.030) in women. CONCLUSIONS: Women are at increased risk of HF after ACS and gender seems to be an outcome-modifier of the relationship between a variable and primary outcome.


Subject(s)
Acute Coronary Syndrome , Diabetes Mellitus , Heart Failure , Myocardial Infarction , Percutaneous Coronary Intervention , Female , Humans , Male , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/epidemiology , Acute Coronary Syndrome/complications , Diabetes Mellitus/etiology , Heart Failure/diagnosis , Heart Failure/epidemiology , Heart Failure/etiology , Myocardial Infarction/epidemiology , Percutaneous Coronary Intervention/adverse effects , Registries , Retrospective Studies , Sex Factors , Stroke Volume , Ventricular Function, Left
15.
Cardiovasc Revasc Med ; 62: 40-47, 2024 May.
Article in English | MEDLINE | ID: mdl-38135568

ABSTRACT

BACKGROUND: Vascular complications (VCs) still represent one of the principal concerns of trans-femoral trans-catheter aortic valve replacement (TF-TAVR). New-generation devices can minimize such complications but the arterial access management is left to the operator's choice. This study aims to describe the rate of VCs in a contemporary cohort of patients undergoing TAVR with new-generation devices and to determine whether an ultrasound-guided (USG) vs. a fluoroscopy-guided (FG) femoral access management has an impact on their prevention. METHODS: This is a prospective, observational, multicenter study. Consecutive patients undergoing TAVR with new-generation devices were analyzed from January 2022 to October 2022 in five tertiary care centers. Femoral accesses were managed according to the operator's preferences. All the patients underwent a pre-discharge peripheral ultrasound control. VCs and bleedings were the main endpoints of interest. RESULTS: A total of 458 consecutive patients were enrolled (274 in the USG group and 184 in the FG group). VCs occurred in 6.5 % of the patients (5.2 % minor and 1.3 % major). There was no difference between the USG and the FG groups in terms of any VCs (7.3 % vs. 5.4 %; p = 0.4), or any VARC-3 bleedings (6.9 % vs 6 %, p = 0.9). At logistic regression analysis, the two guidance strategies did not result as predictors of VCs (odds Ratio 0.8, 95 % Confidence Interval 0.46-1.4; P = 0.4). CONCLUSIONS: In a contemporary cohort of patients undergoing TAVR with new-generation devices, the occurrence of VCs is low and mostly represented by minor VCs. USG and FG modalities did not affect the rate of VCs.


Subject(s)
Aortic Valve , Catheterization, Peripheral , Femoral Artery , Punctures , Radiography, Interventional , Registries , Transcatheter Aortic Valve Replacement , Ultrasonography, Interventional , Humans , Femoral Artery/diagnostic imaging , Male , Female , Prospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Aged , Fluoroscopy , Treatment Outcome , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Risk Factors , Radiography, Interventional/adverse effects , Heart Valve Prosthesis , Time Factors , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Prosthesis Design
17.
JACC Cardiovasc Interv ; 16(20): 2514-2524, 2023 10 23.
Article in English | MEDLINE | ID: mdl-37879803

ABSTRACT

BACKGROUND: Nearly 20% of patients on ticagrelor experience dyspnea, which may lead to treatment discontinuation in up to one-third of cases. OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of dyspnea-related ticagrelor discontinuation after percutaneous coronary intervention (PCI). METHODS: In the TWILIGHT (Ticagrelor With Aspirin or Alone in High-Risk Patients After Coronary Intervention) trial, after 3 months of ticagrelor plus aspirin, patients were maintained on ticagrelor and randomized to aspirin or placebo for 1 year. The occurrence of dyspnea associated with ticagrelor discontinuation was evaluated among all patients enrolled in the trial. A landmark analysis was performed at 3 months after PCI, that is, the time of randomization. Predictors of dyspnea-related ticagrelor discontinuation were obtained from multivariable Cox regression with stepwise selection of candidate variables. RESULTS: The incidence of dyspnea-related ticagrelor discontinuation was 6.4% and 9.1% at 3 and 15 months after PCI, respectively. Independent predictors included Asian race (lower risk), smoking, prior PCI, hypercholesterolemia, prior coronary artery bypass, peripheral artery disease, obesity, and older age. Among 179 patients who discontinued ticagrelor because of dyspnea after randomization, ticagrelor monotherapy was not associated with a higher risk of subsequent ischemic events (composite of all-cause death, myocardial infarction, or stroke) compared with ticagrelor plus aspirin (5.0% vs 7.1%; P = 0.566). CONCLUSIONS: In the TWILIGHT trial, dyspnea-related ticagrelor discontinuation occurred in almost 1 in 10 patients and tended to occur earlier rather than late after PCI. Several demographic and clinical conditions predicted its occurrence, and their assessment may help identify subjects at risk for therapy nonadherence.


Subject(s)
Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors , Humans , Ticagrelor , Percutaneous Coronary Intervention/adverse effects , Hemorrhage/chemically induced , Treatment Outcome , Drug Therapy, Combination , Aspirin , Dyspnea/chemically induced , Dyspnea/diagnosis , Dyspnea/drug therapy
18.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Article in English | MEDLINE | ID: mdl-37668097

ABSTRACT

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Retrospective Studies , Prosthesis Design , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects
19.
Catheter Cardiovasc Interv ; 102(7): 1364-1375, 2023 12.
Article in English | MEDLINE | ID: mdl-37698335

ABSTRACT

BACKGROUND: Extremely large aortic valve anatomy is one of the remaining limitations leading to exclusion of patients for transcatheter aortic valve replacement (TAVR). AIMS: The newly approved Myval 32 mm device is designed for use in aortic annulus areas up to 840 mm2 . Here we want to share the initial worldwide experience with the device. METHODS AND RESULTS: Retrospective data were collected from 10 patients with aortic stenosis and very large annular anatomy (mean area 765.5 mm2 ), who underwent implantation with 32 mm Myval transcatheter heart valve at eight centers. Valve Academic Research Consortium-2 device success was achieved in all cases. Mild paravalvular leak was observed in three patients and two patients required new pacemaker implantation. One patient experienced retroperitoneal hemorrhage caused by the contralateral 6 F sheath and required surgical revision. No device-related complications, stroke, or death from any cause occurred within the 30-day follow-up period. In a studied cohort of 2219 consecutive TAVR-screened patients from a central European site, only 0.27% of patients showed larger anatomy than covered by the 32 mm Myval device by instructions for use without off-label use of overexpansion. This rate was significantly higher for the 34 mm Evolut Pro (1.8%) and 29 mm Sapien 3 (2.1%) devices. CONCLUSIONS: The Myval 32 mm prosthesis showed promising initial results in a cohort of patients who previously had to be excluded from TAVR. It is desirable that all future TAVR systems accommodate larger anatomy to allow optimal treatment of all patients.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Retrospective Studies , Treatment Outcome , Prosthesis Design , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects
20.
Am J Cardiol ; 206: 320-329, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37734293

ABSTRACT

The present study aimed to identify patients at a higher risk of hospitalization for heart failure (HF) in a population of patients with acute coronary syndrome (ACS) treated with percutaneous coronary revascularization without a history of HF or reduced left ventricular (LV) ejection fraction before the index admission. We performed a Cox regression multivariable analysis with competitive risk and machine learning models on the incideNce and predictOrs of heaRt fAiLure After Acute coronarY Syndrome (CORALYS) registry (NCT04895176), an international and multicenter study including consecutive patients admitted for ACS in 16 European Centers from 2015 to 2020. Of 14,699 patients, 593 (4.0%) were admitted for the development of HF up to 1 year after the index ACS presentation. A total of 2 different data sets were randomly created, 1 for the derivative cohort including 11,626 patients (80%) and 1 for the validation cohort including 3,073 patients (20%). On the Cox regression multivariable analysis, several variables were associated with the risk of HF hospitalization, with reduced renal function, complete revascularization, and LV ejection fraction as the most relevant ones. The area under the curve at 1 year was 0.75 (0.72 to 0.78) in the derivative cohort, whereas on validation, it was 0.72 (0.67 to 0.77). The machine learning analysis showed a slightly inferior performance. In conclusion, in a large cohort of patients with ACS without a history of HF or LV dysfunction before the index event, the CORALYS HF score identified patients at a higher risk of hospitalization for HF using variables easily accessible at discharge. Further approaches to tackle HF development in this high-risk subset of patients are needed.


Subject(s)
Acute Coronary Syndrome , Heart Failure , Humans , Acute Coronary Syndrome/epidemiology , Acute Coronary Syndrome/therapy , Acute Coronary Syndrome/complications , Heart Failure/epidemiology , Heart Failure/therapy , Heart Failure/etiology , Hospitalization , Patient Discharge , Ventricular Function, Left