Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 80(2): 024302, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19256665

ABSTRACT

A novel technology and instrumentation for fine needle aspiration (FNA) breast biopsy guidance is presented. This technology is based on spectral-domain low coherence interferometry (SD-LCI). The method, apparatus, and preliminary in vitro/in vivo results proving the viability of the method and apparatus are presented in detail. An advanced tissue classification algorithm, preliminarily tested on breast tissue specimens and a mouse model of breast cancer is presented as well. Over 80% sensitivity and specificity in differentiating all tissue types and 93% accuracy in differentiating fatty tissue from fibrous or tumor tissue was obtained with this technology and apparatus. These results suggest that SD-LCI could help for more precise needle placement during the FNA biopsy and therefore could substantially reduce the number of the nondiagnostic aspirates and improve the sensitivity and specificity of the FNA procedures.


Subject(s)
Biopsy, Fine-Needle/instrumentation , Breast Neoplasms/pathology , Breast/pathology , Interferometry/instrumentation , Surgery, Computer-Assisted/instrumentation , Tomography, Optical Coherence/instrumentation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Humans , Reproducibility of Results , Sensitivity and Specificity
2.
Opt Express ; 15(25): 16808-17, 2007 Dec 10.
Article in English | MEDLINE | ID: mdl-19550971

ABSTRACT

We present a three-dimensional (3D) tracker for a clinical ophthalmic spectral domain optical coherence tomography (SD-OCT) system that combines depth-tracking with lateral tracking, providing a stabilized reference frame for 3D data recording and post acquisition analysis. The depth-tracking system is implemented through a real-time dynamic feedback mechanism to compensate for motion artifact in the axial direction. Active monitoring of the retina and adapting the reference arm of the interferometer allowed the whole thickness of the retina to be stabilized to within +/-100 mum. We achieve a relatively constant SNR from image to image by stabilizing the image of the retina with respect to the depth dependent sensitivity of SD-OCT. The depth tracking range of our system is 5.2 mm in air and the depth is adjusted every frame.nhancement in the stability of the images with the depth-tracking algorithm is demonstrated on a healthy volunteer.

SELECTION OF CITATIONS
SEARCH DETAIL
...