Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
AJNR Am J Neuroradiol ; 41(2): 286-292, 2020 02.
Article in English | MEDLINE | ID: mdl-32001447

ABSTRACT

BACKGROUND AND PURPOSE: Delayed leukoencephalopathy is a rare complication that occurs after endovascular coiling of cerebral aneurysms. We aimed to describe a clinical picture of delayed leukoencephalopathy and explore potential associations with procedural characteristics. MATERIALS AND METHODS: We considered endovascular coiling procedures for cerebral aneurysms performed between January 2006 and December 2017 in our institution with follow-up MRIs. We used logistic regression models to estimate the ORs of delayed leukoencephalopathy for each procedural characteristic. RESULTS: We reviewed 1754 endovascular coiling procedures of 1594 aneurysms. Sixteen of 1722 (0.9%) procedures demonstrated delayed leukoencephalopathy on follow-up FLAIR MR imaging examinations after a median period of 71.5 days (interquartile range, 30-101 days) in the form of high-signal changes in the white matter at locations remote from the coil mass. Seven patients had headaches or hemiparesis, and 9 patients were asymptomatic. All imaging-associated changes improved subsequently. We found indications suggesting an association between delayed leukoencephalopathy and the number of microcatheters used per procedure (P = .009), along with indications suggesting that these procedures required larger median volumes of contrast medium (225 versus 175 mL, OR = 5.5, P = .008) as well as a longer median fluoroscopy duration (123.6 versus 99.3 minutes, OR = 3.0, P = .06). Our data did not suggest that delayed leukoencephalopathy was associated with the number of coils (P = .57), microguidewires (P = .35), and guiding systems (P = .57). CONCLUSIONS: Delayed leukoencephalopathy after coiling of cerebral aneurysms may have multiple etiologies such as foreign body emboli, contrast-induced encephalopathy, or hypersensitivity reaction to foreign bodies.


Subject(s)
Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Intracranial Aneurysm/surgery , Leukoencephalopathies/etiology , Postoperative Complications/etiology , Adult , Aged , Endovascular Procedures/instrumentation , Female , Humans , Incidence , Leukoencephalopathies/epidemiology , Male , Middle Aged , Postoperative Complications/epidemiology , Stents , Treatment Outcome
2.
AJNR Am J Neuroradiol ; 37(2): 317-23, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26359152

ABSTRACT

BACKGROUND AND PURPOSE: Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. MATERIALS AND METHODS: Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. RESULTS: Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P < .0001) and quantitative (P < .001) analyses showed significant reduction of the metal artifacts after application of the Metal Artifact Reduction prototype software. CONCLUSIONS: The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization.


Subject(s)
Artifacts , Image Processing, Computer-Assisted/methods , Intracranial Aneurysm/diagnostic imaging , Software , Tomography, X-Ray Computed/methods , Animals , Disease Models, Animal , Embolization, Therapeutic/instrumentation , Embolization, Therapeutic/methods , Intracranial Aneurysm/therapy , Stents , Swine
3.
Masui ; 41(9): 1450-4, 1992 Sep.
Article in Japanese | MEDLINE | ID: mdl-1433876

ABSTRACT

In awake subjects the positive chronotropic effect of intravenously administered atropine 10 micrograms.kg-1 has been demonstrated to be blunted by preanesthetic medication of oral clonidine 5 micrograms.kg-1. The aim of the present study is to investigate whether general anesthesia could alter the clonidine-induced attenuation of positive chronotropic effect by atropine. Thirty-two patients were randomly assigned to one of the two groups; patients of the clonidine group received oral clonidine 5 micrograms.kg-1 (n = 12), whereas those of the control group received no clonidine. General anesthesia was induced with intravenous thiamylal 4-5 mg.kg-1, and was maintained with enflurane and nitrous oxide in oxygen after endotracheal intubation. Following the stable circulatory period of 10 min, hemodynamic measurements were made at 1 min intervals for 10 min after atropine 10 micrograms.kg-1 was administered intravenously as a bolus in both groups. A significant attenuation in heart rate response to intravenous atropine 10 micrograms.kg-1 was observed in patients receiving clonidine 5 micrograms.kg-1, as compared with that in the control group (P less than 0.01); maximal increases in heart rate were 15 +/- 8 and 22 +/- 6 beats.min-1 (mean +/- SD) in the clonidine and control groups, respectively. It is concluded that clonidine 5 micrograms.kg-1 blunts the heart rate response to intravenous atropine 10 micrograms.kg-1 in patients anesthetized with enflurane and nitrous oxide in oxygen.


Subject(s)
Anesthesia, General , Atropine/antagonists & inhibitors , Clonidine/pharmacology , Heart Rate/drug effects , Administration, Oral , Adolescent , Adult , Atropine/administration & dosage , Clonidine/administration & dosage , Humans , Injections, Intravenous , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...