1.
Arch Plast Surg ; 50(5): 501-506, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37808330

ABSTRACT

This article portrays the authors' experience with a complex lower limb bone and soft tissue defect, following chronic osteomyelitis and pathological fracture, which was managed by the multidisciplinary orthoplastic team. The decision for functional amputation versus limb salvage was deemed necessary, enhanced by the principles of "spare parts" in reconstructive microsurgery. This case describes the successful use of the osteocutaneous distal tibia turn-up fillet flap that allowed "lowering the level of the amputation" from a through knee to a below-knee amputation (BKA) to preserve the knee joint function. We comprehensibly review reports of turn-up flaps which effectively lower the level of amputation, also applying "spare-parts" surgery principles and explore how these concepts refine complex orthoplastic approaches when limb salvage is not possible to enhance function. The osteocutaneous distal tibia turn-up fillet flap is a robust technique for modified BKA reconstructions that provides sufficient bone length to achieve a tough, sensate stump and functional knee joint.

3.
Bone Joint J ; 103-B(6): 1168-1172, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34058877

ABSTRACT

AIMS: The STRYDE nail is an evolution of the PRECICE Intramedullary Limb Lengthening System, with unique features regarding its composition. It is designed for load bearing throughout treatment in order to improve patient experience and outcomes and allow for simultaneous bilateral lower limb lengthening. The literature published to date is limited regarding outcomes and potential problems. We report on our early experience and raise awareness for the potential of adverse effects from this device. METHODS: This is a retrospective review of prospective data collected on all patients treated in our institution using this implant. We report the demographics, nail accuracy, reliability, consolidation index, and cases where concerning clinical and radiological findings were encountered. There were 14 STRYDE nails implanted in nine patients (three male and six female) between June 2019 and September 2020. Mean age at surgery was 33 years (14 to 65). Five patients underwent bilateral lengthening (two femoral and three tibial) and four patients unilateral femoral lengthening for multiple aetiologies. RESULTS: At the time of reporting, eight patients (13 implants) had completed lengthening. Osteolysis and periosteal reaction at the junction of the telescopic nail was evident in nine implants. Five patients experienced localized pain and swelling. Macroscopic appearances following retrieval were consistent with corrosion at the telescopic junction. Tissue histology was consistent with effects of focal metallic wear debris. CONCLUSION: From our early experience with this implant we have found the process of lengthening to be accurate and reliable with good regenerate formation and consolidation. Proposed advantages of early load bearing and the ability for bilateral lengthening are promising. We have, however, encountered concerning clinical and radiological findings in several patients. We have elected to discontinue its use to allow further investigation into the retrieved implants and patient outcomes from users internationally. Cite this article: Bone Joint J 2021;103-B(6):1168-1172.


Subject(s)
Bone Lengthening/instrumentation , Bone Nails , Leg Length Inequality/surgery , Adolescent , Adult , Aged , Device Removal , Female , Femur/diagnostic imaging , Femur/surgery , Humans , Leg Length Inequality/diagnostic imaging , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Tibia/diagnostic imaging , Tibia/surgery
4.
Eur J Orthop Surg Traumatol ; 31(5): 957-966, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33778904

ABSTRACT

Fracture-related infection (FRI) is one of the most challenging complications following operative management of fractures. It can have profound implications for the patient, can be associated with considerable morbidity and often lead to impaired outcomes. There are significant healthcare-related costs. In recent years, there has been significant progress towards developing preventative strategies. Furthermore, diagnostic algorithms and management protocols have recently been reported. Lack of a strong evidence base has previously hindered efforts to implement these and develop established standards of care. There are multiple aspects of care that need to be considered and a multi-disciplinary approach is recommended. In this narrative review, we present the most up-to-date recommendations in the prevention, diagnosis and management of FRI.


Subject(s)
Fractures, Bone , Surgical Wound Infection , Humans , Surgical Wound Infection/diagnosis , Surgical Wound Infection/prevention & control
5.
Strategies Trauma Limb Reconstr ; 11(3): 193-198, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27738975

ABSTRACT

A mechanical study investigating the use of two different methods (grub and bolt screws) to secure external fixation half pins to circular frames. A four part experiment: (1) Grub and bolt screws were used to secure half pins in Taylor Spatial frames. Loosening torques were measured using a calibrated torque wrench. (2) Using universal testing machine (UTM), axial loading was applied to establish thresholds for loosening in grub and bolt screw constructs. (3) We established the application torque to produce failure at the head-driver interface using these two methods. (4) Grub and bolt screw constructs were created controlling torque. Using UTM, axial loading was applied to establish thresholds for loosening. Statistical analysis was conducted using SPSS v20.0.0. (1) Higher torque is employed when bolt rather than grub screws is used to secure half pins on Rancho cubes (p < 0.05). (2) Loading threshold for loosening is higher in bolt screw constructs when the torque applied to secure the constructs is not controlled (p < 0.05). (3) Torque required for failure at the head-driver interface was 5.3 Nm for grub screws and 9.9 Nm for bolts. (4) Loading threshold for loosening is higher in grub screw constructs when the same torque was applied to secure them (p < 0.05). Bolt screws can be employed to secure the half pin-frame interface. They offer good stability and reduce failure at the head-driver interface. Further research is needed to determine the mechanical properties of such constructs in vivo.

6.
Open Orthop J ; 6: 327-39, 2012.
Article in English | MEDLINE | ID: mdl-22927893

ABSTRACT

Management of patellofemoral joint pathology is challenging as a result of the unique and complex organization of static forces and dynamic factors contributing to its functional capacity. Anterior knee pain is a common musculoskeletal complaint seen daily in the practices of primary care physicians, rheumatologists, and orthopedic surgeons. The key to successful treatment lies not only in the correct diagnosis of a chondral defect, but more importantly, in the accurate identification of associated pathomechanical factors. Appreciating the pathoanatomic basis of the disease and addressing imbalances and anatomical abnormalities should guide treatment.Despite the complexity of the interplay of various components it is essential to attempt to describe patellar malalignement as a clinical entity in order to proceed with appropriate surgical management and successful outcomes. The goals of patellofemoral re- alignment surgery should be to create both a stable environment for optimal extensor mechanism performance and an appropriate load transmission for optimal cartilage wear and joint loading. In the context of this article we will review the operative management of patellofemoral malalignment; the indications for surgery, the different techniques available and the evidence regarding their effectiveness.A large number of procedures have been employed and they have all undergone various modifications over the course of the years. The majority of publications are retrospective series in poorly defined population groups. There are significant methodological inconsistencies and as a result there is lack of strong evidence base for the majority of these procedures.

SELECTION OF CITATIONS
SEARCH DETAIL
...