Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Coll Physicians Surg Pak ; 33(8): 932-935, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37553936

ABSTRACT

OBJECTIVE: To evaluate the histopathological results of conjunctival masses suspected to be malignant based on biomicroscopic examination. STUDY DESIGN: Observational study. Place and Duration of the Study: Department of Ophthalmology, Celal Bayar University, Hafsa Sultan Hospital, Manisa, Turkiye, from November 2013 to February 2021. METHODOLOGY: Patients who underwent excision for the diagnosis and treatment of conjunctival surface masses with clinical suspicion of malignancy were evaluated retrospectively. The masses were categorised as benign, premalignant, and malignant lesions according to the histopathological results. The distribution of conjunctival masses was analysed according to patients' gender and age groups. RESULTS: The study included 98 conjunctival masses in 98 patients (57.1% men, mean age 48.6±21.85 years). On pathological examination, 63 of the masses were found to be benign (64.3%), 22 were premalignant (22.4%), and 13 were malignant (13.3%). The most common benign lesion was nevus (n=21, 21.4%). All detected premalignant lesions were conjunctival intraepithelial neoplasms (CIN), detected in 22 patients (22.4%). Of these, 13 patients (13.3%) had carcinoma in situ (CIN III). Thirteen (13.3%) of the masses were malignant, the most common being squamous cell carcinoma (n=10, 10.2%). The frequency of premalignant and malignant lesions increased with age (p<0.001). There was no statistical relationship between malignancy and gender (p=0.619). CONCLUSION: Most conjunctival masses in this series were benign, with nevi being the most common. The most common premalignant and malignant lesions were intraepithelial neoplasia and squamous cell carcinoma, respectively. Malignant conjunctival lesions were more common in older patients. KEY WORDS: Conjunctival nevus, Conjunctival intraepithelial neoplasia, Squamous cell carcinoma.


Subject(s)
Carcinoma, Squamous Cell , Conjunctival Neoplasms , Humans , Male , Female , Adult , Middle Aged , Aged , Conjunctival Neoplasms/epidemiology , Conjunctival Neoplasms/pathology , Conjunctival Neoplasms/surgery , Nevus, Pigmented/pathology , Carcinoma, Squamous Cell/epidemiology , Carcinoma, Squamous Cell/pathology , Carcinoma, Squamous Cell/surgery , Lymph Node Excision , Retrospective Studies , Carcinoma in Situ/parasitology , Carcinoma in Situ/surgery
2.
Eur J Ophthalmol ; 32(4): 2404-2411, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34374308

ABSTRACT

PURPOSE: This study aimed to compare type 1 choroidal neovascularization (CNV) characteristics in eyes with pachychoroid neovasculopathy (PNV) and neovascular age-related macular degeneration (nAMD) using optical coherence tomography angiography (OCTA). METHODS: Treatment naive 23 eyes of 23 patients with PNV and 24 eyes of 24 patients with nAMD were evaluated. The height of pigment epithelial detachment (PED) and the central macular thickness were determined. OCTA sensitivity, CNV area, morphological patterns, and retinal superficial capillary plexus vessel density (SCP-VD) values were compared. The frequency of quiescent CNV, subretinal hyperreflective exudation (SHE), subretinal/intraretinal fluid, serous PED, double-layer sign (DLS), and pachyvessels were noted. RESULTS: CNV was detected on OCTA in 83.3% of nAMD eyes and 91.3% of PNV eyes (p = 0.66). Indistinct pattern was more common (74% vs 50%) and the CNV area (mm2) was smaller in PNV (0.77 ± 0.54 vs 1.57 ± 1.43) but did not reach significant levels (p = 0.27 and 0.33 respectively). SCP-VD was similar between the groups (p = 0.38). Statistically significant differences were found between groups in age and subfoveal choroidal thickness (p < 0.05). DLS and pachyvessels were found to be more frequently in PNV (p < 0.05). However, both groups had similar rates of quiescent CNV, SHE, subretinal/intraretinal fluid, and serous PED (p > 0.05). CONCLUSION: Morphological features, area, and activation findings of type 1 CNV may play a limited role in differentiating nAMD and PNV cases.


Subject(s)
Choroidal Neovascularization , Macular Degeneration , Retinal Detachment , Choroid/blood supply , Choroidal Neovascularization/diagnosis , Fluorescein Angiography/methods , Humans , Retinal Detachment/diagnosis , Retrospective Studies , Tomography, Optical Coherence/methods
3.
J Cataract Refract Surg ; 47(5): 612-617, 2021 05 01.
Article in English | MEDLINE | ID: mdl-33252564

ABSTRACT

PURPOSE: To compare the effects of phacoemulsification surgery (PE) using an anterior chamber maintainer (ACM) and conventional PE using an ophthalmic viscosurgical device (OVD) on corneal endothelial cells. SETTING: Department of Ophthalmology, Celal Bayar University, Manisa, Turkey. DESIGN: Prospective randomized controlled trial. METHODS: Eyes in the OVD group (n = 50) underwent conventional PE, whereas eyes in the ACM group (n = 50) underwent PE using an ACM. Endothelial cell density (ECD), coefficient of variation (CV), hexagonality (HEX), and noncontact central corneal thickness (CCT) measurements were performed by specular microscopy before and at 1 month, 3 months, and 6 months after PE. RESULTS: This study included 100 eyes of 97 patients undergoing PE. The mean age was 64.7 ± 10.6 years in the OVD group, 64.0 ± 12.6 years in the ACM group (P > .05). The groups did not differ significantly in preoperative ECD, CV, HEX, and CCT or total PE time (P > .05 for all). ECD was significantly lower in the ACM group compared with the OVD group at postoperative 1 month, 3 months, and 6 months (P = .002, P = .002, and P = .001, respectively). Similarly, ECD loss compared with preoperative value was greater in the ACM group at all postoperative timepoints (P = .003, P = .001, and P = .001, respectively). CV increased and HEX decreased in both groups postoperatively (P > .05 for both). CCT showed a transient increase of less than 10 µm at postoperative 1 month in both groups (P = .296). CONCLUSIONS: PE with ACM was associated with greater corneal ECD loss compared with conventional PE. ACM should not be used during PE in patients with limited corneal endothelial reserve.


Subject(s)
Phacoemulsification , Anterior Chamber , Cell Count , Endothelial Cells , Endothelium, Corneal , Humans , Lens Implantation, Intraocular , Middle Aged , Prospective Studies
4.
Turk J Ophthalmol ; 49(3): 130-133, 2019 06 27.
Article in English | MEDLINE | ID: mdl-31245973

ABSTRACT

Objectives: To compare intraocular pressure (IOP) measurements obtained with the Icare Pro tonometer used in clinical practice and the Icare One self-tonometer. Materials and Methods: Fifty-two eyes of 52 healthy, right-handed individuals with no prior intraocular surgery or ocular trauma, structural ocular pathology, or systemic disease were evaluated. IOP was first measured using the Icare Pro tonometer. The participants were then told how to use the Icare One tonometer and asked to measure their own IOP. The results were analyzed statistically using SPSS v.24. Results: Of the 52 healthy participants, 16 (30.7%) were male and 36 (69.3%) were female. Their mean age was 31.6±6.3 (23-47) years. Mean IOP measured with the Icare Pro was 17.10±6.2 (11.5-25.2) mmHg, and the mean self-measured IOP with Icare One was 14.01±3.4 (7-24) mmHg. When the two methods were compared using Levene's t-test, there was a significant mean difference of -3.08±0.6 (95% confidence interval: -4.39 -1.78; p<0.001). Conclusion: In this study, there was a significant difference between the IOP measurements we made using the Icare Pro and the participants' self-measured IOP using the Icare One, with the latter being relatively lower. This may be related to the fact that the participants were unfamiliar with using the Icare One. Although the Icare One is a promising tool for glaucoma patients to self-monitor their IOP, further studies are needed.


Subject(s)
Glaucoma/diagnosis , Intraocular Pressure/physiology , Tonometry, Ocular/instrumentation , Adult , Equipment Design , Female , Glaucoma/physiopathology , Healthy Volunteers , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Young Adult
5.
Turk J Ophthalmol ; 49(1): 6-9, 2019 02 28.
Article in English | MEDLINE | ID: mdl-30829018

ABSTRACT

Objectives: It is important to determine variables that influence intraocular pressure (IOP) measurement. This study aimed to evaluate the effect of body position on IOP. Materials and Methods: The study included 52 right eyes of 52 patients who presented to the ophthalmology department of our hospital and had no ocular disease except refractive errors. IOP was measured with an Icare PRO tonometer while patients were in sitting, standing, and supine positions, with intervals of 10 minutes between the positions. Correlations between the results were evaluated using Spearman's correlation analysis and Wilcoxon tests. Results: Thirty-six of the 52 patients were female, 16 were male. Mean age was 31.65±6.30 (23-47) years. Mean IOP values in the sitting, standing, and lying positions were 17.76±3.41 (12.70-25.60) mmHg, 17.10±3.27 (11.50-25.20) mmHg, and 18.46±4.67 (10.50-29.40) mmHg, respectively. There were no statistically significant differences between measurements taken in the different positions (p=0.112, p=0.472, p=0.071). We observed that there was no relationship between age and body position (p>0.45, p>0.79, p>0.77) or between gender and position (p>0.59, p>0.69, p>0.54). Conclusion: Gender and age had no effect on IOP measured in different body positions. There were also no significant differences between IOP values measured in the different positions. Therefore, we believe the portable Icare PRO tonometer can be used for patients who are confined to bed and will provide IOP measurements that are concordant with values obtained while sitting.


Subject(s)
Glaucoma/diagnosis , Intraocular Pressure/physiology , Posture/physiology , Tonometry, Ocular/methods , Adult , Age Factors , Female , Humans , Male , Middle Aged , Sex Factors , Young Adult
6.
Neuroophthalmology ; 37(2): 68-72, 2013.
Article in English | MEDLINE | ID: mdl-28163758

ABSTRACT

We report a case of a 32-year-old female patient who presented with decreased vision on both eyes and headache. In fundus examination, both eyes had elevation of the optic disc and star shaped hard exudates in the macula. Magnetic resonance imaging was completely normal except the saccular dilatation of bilateral optic nerve sheath. The patient was treated with oral steroids following high-dose intravenous methylprednisolone. She displayed good anatomical and functional results during the follow-up. This case raises the possibility that optic nerve sheath enlargement, probably induced by an idiopathic inflammatory optic neuritis, may simulate dural ectasia of the optic nerve sheath.

SELECTION OF CITATIONS
SEARCH DETAIL
...