Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Biosens Bioelectron X ; 10: 100105, 2022 May.
Article in English | MEDLINE | ID: mdl-35036904

ABSTRACT

Point of care (PoC) devices are highly demanding to control current pandemic, originated from severe acute respiratory syndrome Coronavirus 2 (SARS-CoV-2). Though nucleic acid-based methods such as RT-PCR are widely available, they require sample preparation and long processing time. PoC diagnostic devices provide relatively faster and stable results. However they require further investigation to provide high accuracy and be adaptable for the new variants. In this study, laser-scribed graphene (LSG) sensors are coupled with gold nanoparticles (AuNPs) as stable promising biosensing platforms. Angiotensin Converting Enzyme 2 (ACE2), an enzymatic receptor, is chosen to be the biorecognition unit due to its high binding affinity towards spike proteins as a key-lock model. The sensor was integrated to a homemade and portable potentistat device, wirelessly connected to a smartphone having a customized application for easy operation. LODs of 5.14 and 2.09 ng/mL was achieved for S1 and S2 protein in the linear range of 1.0-200 ng/mL, respectively. Clinical study has been conducted with nasopharyngeal swabs from 63 patients having alpha (B.1.1.7), beta (B.1.351), delta (B.1.617.2) variants, patients without mutation and negative patients. A machine learning model was developed with accuracy of 99.37% for the identification of the SARS-Cov-2 variants under 1 min. With the increasing need for rapid and improved disease diagnosis and monitoring, the PoC platform proved its potential for real time monitoring by providing accurate and fast variant identification without any expertise and pre sample preparation, which is exactly what societies need in this time of pandemic.

2.
Biosens Bioelectron ; 180: 113116, 2021 May 15.
Article in English | MEDLINE | ID: mdl-33662847

ABSTRACT

Improvements in the laser-scribed graphene (LSG)-based electrodes are critical to overcoming limitations of bare LSG electrodes in terms of sensitivity, direct immobilization of detection probes for biosensor fabrication, and ease of integration with point-of-care (POC) devices. Herein, we introduce a new class of nanostructured gold modified LSG (LSG-AuNS) electrochemical sensing system comprising LSG-AuNS working electrode, LSG reference, and LSG counter electrode. LSG-AuNS electrodes are realized by electrodeposition of gold chloride (HAuCl4) solution, which gave~2-fold enhancement in sensitivity and electrocatalytic activity compared to bare LSG electrode and commercially available screen-printed gold electrode (SPAuE). We demonstrate LSG-AuNS electrochemical aptasensor for detecting human epidermal growth factor receptor 2 (Her-2) with a limit of detection (LOD) of 0.008 ng/mL and a linear range of 0.1-200 ng/mL. LSG-AuNS-aptasensor can easily detect different concentrations of Her-2 spiked in undiluted human serum. Finally, to show the LSG-AuNS sensor system's potential to develop POC biosensor devices, we integrated LSG-AuNS electrodes with a handheld electrochemical system operated using a custom-developed mobile application.


Subject(s)
Biosensing Techniques , Graphite , Metal Nanoparticles , Biomarkers , Electrochemical Techniques , Electrodes , Gold , Humans , Lasers , Limit of Detection , Point-of-Care Testing
SELECTION OF CITATIONS
SEARCH DETAIL
...