Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Radiat Oncol ; 19(1): 4, 2024 Jan 08.
Article in English | MEDLINE | ID: mdl-38191400

ABSTRACT

BACKGROUND: The aim of the present study is to examine the impact of kV-CBCT-based online adaptive radiation therapy (ART) on dosimetric parameters in comparison to image-guided-radiotherapy (IGRT) in consecutive patients with tumors in the head and neck region from a prospective registry. METHODS: The study comprises all consecutive patients with tumors in the head and neck area who were treated with kV-CBCT-based online ART or IGRT-modus at the linear-accelerator ETHOS™. As a measure of effectiveness, the equivalent-uniform-dose was calculated for the CTV (EUDCTV) and organs-at-risk (EUDOAR) and normalized to the prescribed dose. As an important determinant for the need of ART the interfractional shifts of anatomic landmarks related to the tongue were analyzed and compared to the intrafractional shifts. The latter determine the performance of the adapted dose distribution on the verification CBCT2 postadaptation. RESULTS: Altogether 59 consecutive patients with tumors in the head-and-neck-area were treated from 01.12.2021 to 31.01.2023. Ten of all 59 patients (10/59; 16.9%) received at least one phase within a treatment course with ART. Of 46 fractions in the adaptive mode, irradiation was conducted in 65.2% of fractions with the adaptive-plan, the scheduled-plan in the remaining. The dispersion of the distributions of EUDCTV-values from the 46 dose fractions differed significantly between the scheduled and adaptive plans (Ansari-Bradley-Test, p = 0.0158). Thus, the 2.5th percentile of the EUDCTV-values by the adaptive plans amounted 97.1% (95% CI 96.6-99.5%) and by the scheduled plans 78.1% (95% CI 61.8-88.7%). While the EUDCTV for the accumulated dose distributions stayed above 95% at PTV-margins of ≥ 3 mm for all 8 analyzed treatment phases the scheduled plans did for margins ≥ 5 mm. The intrafractional anatomic shifts of all 8 measured anatomic landmarks were smaller than the interfractional with overall median values of 8.5 mm and 5.5 mm (p < 0.0001 for five and p < 0.05 for all parameters, pairwise comparisons, signed-rank-test). The EUDOAR-values for the larynx and the parotid gland were significantly lower for the adaptive compared with the scheduled plans (Wilcoxon-test, p < 0.001). CONCLUSIONS: The mobile tongue and tongue base showed considerable interfractional variations. While PTV-margins of 5 mm were sufficient for IGRT, ART showed the potential of decreasing PTV-margins and spare dose to the organs-at-risk.


Subject(s)
Head and Neck Neoplasms , Radiotherapy, Image-Guided , Humans , Radiotherapy Planning, Computer-Assisted , Head and Neck Neoplasms/radiotherapy , Head , Neck
2.
Clin Transl Radiat Oncol ; 40: 100628, 2023 May.
Article in English | MEDLINE | ID: mdl-37138702

ABSTRACT

Background and purpose: Definitive radiochemotherapy (RCT) for non-small cell lung cancer (NSCLC) in UICC/TNM I-IVA (singular, oligometastatic) is one of the treatment methods with a potentially curative concept. However, tumour respiratory motion during RT requires exact pre-planning. There are various techniques of motion management like creating internal target volume (ITV), gating, inspiration breath-hold and tracking. The primary goal is to cover the PTV with the prescribed dose while at the same time maximizing dose reduction of surrounding normal tissues (organs at risk, OAR). In this study, two standardized online breath-controlled application techniques used alternately in our department are compared with respect to lung and heart dose. Materials and methods: Twenty-four patients who were indicated for thoracic RT received planning CTs in voluntary deep inspiration breath-hold (DIBH) and in free shallow breathing, prospectively gated in expiration (FB-EH). A respiratory gating system by Varian (Real-time Position Management, RPM) was used for monitoring. OAR, GTV, CTV and PTV were contoured on both planning CTs. The PTV margin to the CTV was 5 mm in the axial and 6-8 mm in the cranio-caudal direction. The consistency of the contours was checked by elastic deformation (Varian Eclipse Version 15.5). RT plans were generated and compared in both breathing positions using the same technique, IMRT over fixed irradiation directions or VMAT. The patients were treated in a prospective registry study with the approval of the local ethics committee. Results: The PTV in expiration (FB-EH) was on average significantly smaller than the PTV in inspiration (DIBH): for tumours in the lower lobe (LL) 431.5 vs. 477.6 ml (Wilcoxon test for connected samples; p = 0.004), in the upper lobe (UL) 659.5 vs. 686.8 ml (p = 0.005). The intra-patient comparison of plans in DIBH and FB-EH showed superiority of DIBH for UL-tumours and equality of DIBH and FB-EH for LL-tumours. The dose for OAR in UL-tumours was lower in DIBH than in FB-EH (mean lung dose p = 0.011; lungV20, p = 0.002; mean heart dose p = 0.016). The plans for LL-tumours in FB-EH showed no difference in OAR compared to DIBH (mean lung dose p = 0.683; V20Gy p = 0.33; mean heart dose p = 0.929). The RT setting was controlled online for each fraction and was robustly reproducible in FB-EH. Conclusion: RT plans for treating lung tumours implemented depend on the reproducibility of the DIBH and advantages of the respiratory situation with respect to OAR. The primary tumour localization in UL correlates with advantages of RT in DIBH, compared to FB-EH. For LL-tumours there is no difference between RT in FB-EH and RT in DIBH with respect to heart or lung exposure and therefore, reproducibility is the dominant criterion. FB-EH is recommended as a very robust and efficient technique for LL-tumours.

4.
Med Phys ; 23(3): 427-304, 1996 Mar.
Article in English | MEDLINE | ID: mdl-8815386

ABSTRACT

We have developed dosemeters based on plastic scintillators for a variety of applications in radiation therapy. The dosemeters consist basically of a tissue-substituting scintillator probe, an optical fiber light guide, and a photomultiplier tube. The background light generated in the light guide can be compensated by a simultaneous measurement of the light from a blind fiber. Plastic scintillator dosemeters combine several advantageous properties which render them superior to other dosemeter types for many applications: minimal disturbance of the radiation field because of the homogeneous detector volume and the approximate water equivalence; no dependence on temperature and pressure (under standard clinical conditions) and angle of radiation incidence; no high voltage in the probe; high spatial resolution due to small detector volumes; direct reading of absorbed doses; and a large dynamical range. The high spatial resolution together with direct reading make these detectors suitable for real-time 3-D dosimetry using multi-channel detector systems. Such a system has been developed for eye plaque dosimetry and successfully employed for dosimetric treatment optimization. The plaque optimization can be performed by dosimetric measurements for the individual patient ("dosimetric treatment planning"). The time consumption for this procedure is less than for a physically correct computer-based therapy planning, e.g., by means of a Monte Carlo simulation.


Subject(s)
Brachytherapy/methods , Eye Neoplasms/radiotherapy , Radiometry/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Scintillation Counting/instrumentation , Biophysical Phenomena , Biophysics , Brachytherapy/statistics & numerical data , Evaluation Studies as Topic , Humans , Radiometry/methods , Radiometry/statistics & numerical data , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/statistics & numerical data , Scintillation Counting/statistics & numerical data , Technology, Radiologic
SELECTION OF CITATIONS
SEARCH DETAIL
...