Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Cancers (Basel) ; 15(23)2023 Nov 29.
Article in English | MEDLINE | ID: mdl-38067333

ABSTRACT

Interfraction anatomic deformations decrease the precision of radiotherapy, which can be improved by online adaptive radiation therapy (oART). However, oART takes time, allowing intrafractional deformations. In this study on focal radiotherapy for bladder cancer, we analyzed the time effect of oART on the equivalent uniform dose in the CTV (EUDCTV) per fraction and for the accumulated dose distribution over a treatment series as measure of effectiveness. A time-dependent digital CTV model was built from deformable image registration (DIR) between pre- and post-adaptation imaging. The model was highly dose fraction-specific. Planning target volume (PTV) margins were varied by shrinking the clinical PTV to obtain the margin-specific CTV. The EUDCTV per fraction decreased by-4.4 ± 0.9% of prescribed dose per min in treatment series with a steeper than average time dependency of EUDCTV. The EUDCTV for DIR-based accumulated dose distributions over a treatment series was significantly dependent on adaptation time and PTV margin (p < 0.0001, Chi2 test for each variable). Increasing adaptation times larger than 10 min by five minutes requires a 1.9 ± 0.24 mm additional margin to maintain EUDCTV for a treatment series. Adaptation time is an important determinant of the precision of oART for one half of the bladder cancer patients, and it should be aimed at to be minimized.

2.
Cancers (Basel) ; 15(22)2023 Nov 15.
Article in English | MEDLINE | ID: mdl-38001692

ABSTRACT

Irradiation with electrons is the primary treatment regime for localized conjunctival low-grade lymphomas. However, radiation-induced cataracts are a major cause of treatment-related morbidity. This study investigates whether lens-sparing electron irradiation produces sufficient disease control rates while preventing cataract formation. All consecutive patients with strictly conjunctival, low-grade Ann Arbor stage IE lymphoma treated with superficial electron irradiation between 1999 and 2021 at our department were reviewed. A total of 56 patients with 65 treated eyes were enrolled with a median follow-up of 65 months. The median dose was 30.96 Gy. A lens-spearing technique featuring a hanging rod blocking the central beam axis was used in 89.2% of all cases. Cumulative incidences of 5- and 10-year infield recurrences were 4.3% and 14.6%, incidences of 5- and 10-year outfield progression were 10.4% and 13.4%. We used patients with involvement of retroorbital structures treated with whole-orbit photon irradiation without lens protection-of which we reported in a previous study-as a control group. The cumulative cataract incidence for patients treated with electrons and lens protection was significantly lower (p = 0.005) when compared to patients irradiated without lens protection. Thus, electrons are an effective treatment option for conjunctival low-grade lymphomas. The presented lens-sparing technique effectively prevents cataract formation.

3.
JAMA Netw Open ; 6(3): e234066, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36947038

ABSTRACT

Importance: Patients with newly diagnosed locally advanced cervical carcinomas or recurrences after surgery undergoing radiochemotherapy whose tumor is unsuited for a brachytherapy boost need high-dose percutaneous radiotherapy with small margins to compensate for clinical target volume deformations and set-up errors. Cone-beam computed tomography-based online adaptive radiotherapy (ART) has the potential to reduce planning target volume (PTV) margins below 5 mm for these tumors. Objective: To compare online ART technologies with image-guided radiotherapy (IGRT) for gynecologic tumors. Design, Setting, and Participants: This comparative effectiveness study comprised all 7 consecutive patients with gynecologic tumors who were treated with ART with artificial intelligence segmentation from January to May 2022 at the West German Cancer Center. All adapted treatment plans were reviewed for the new scenario of organs at risk and target volume. Dose distributions of adapted and scheduled plans optimized on the initial planning computed tomography scan were compared. Exposure: Online ART for gynecologic tumors. Main Outcomes and Measures: Target dose coverage with ART compared with IGRT for PTV margins of 5 mm or less in terms of the generalized equivalent uniform dose (gEUD) without increasing the gEUD for the organs at risk (bladder and rectum). Results: The first 10 treatment series among 7 patients (mean [SD] age, 65.7 [16.5] years) with gynecologic tumors from a prospective observational trial performed with ART were compared with IGRT. For a clinical PTV margin of 5 mm, IGRT was associated with a median gEUD decrease in the interfractional clinical target volume of -1.5% (90% CI, -31.8% to 2.9%) for all fractions in comparison with the planned dose distribution. Online ART was associated with a decrease of -0.02% (90% CI, -3.2% to 1.5%), which was less than the decrease with IGRT (P < .001). This was not associated with an increase in the gEUD for the bladder or rectum. For a PTV margin of 0 mm, the median gEUD deviation with IGRT was -13.1% (90% CI, -47.9% to 1.6%) compared with 0.1% (90% CI, -2.3% to 6.6%) with ART (P < .001). The benefit associated with ART was larger for a PTV margin of 0 mm than of 5 mm (P = .004) due to spreading of the cold spot at the clinical target volume margin from fraction to fraction with a median SD of 2.4 cm (90% CI, 1.9-3.4 cm) for all patients. Conclusions and Relevance: This study suggests that ART is associated with an improvement in the percentage deviation of gEUD for the interfractional clinical target volume compared with IGRT. As the gain of ART depends on fractionation and PTV margin, a strategy is proposed here to switch from IGRT to ART, if the delivered gEUD distribution becomes unfavorable in comparison with the expected distribution during the course of treatment.


Subject(s)
Genital Neoplasms, Female , Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Humans , Female , Aged , Radiotherapy, Image-Guided/methods , Genital Neoplasms, Female/diagnostic imaging , Genital Neoplasms, Female/radiotherapy , Artificial Intelligence , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
4.
Cancers (Basel) ; 14(19)2022 Sep 28.
Article in English | MEDLINE | ID: mdl-36230660

ABSTRACT

The main objective of this prospective observational study was the characterization of the feasibility and early outcome of image-guided (IG) volumetric modulated arc (VMAT) radiosurgery (SRS) followed by resection for patients with large intraocular melanoma. Our study included consecutive patients with unfavorable-risk melanoma, enrolled in an ophthalmic oncology center. IG-VMAT-SRS was applied by high-resolution 4D image guidance and monitoring. Current stereotactic technique parameters were evaluated for comparison. Side effects and eye function, based on a 5-point CTC assessment score, were quantified. In patients with tumors located more than 0.7-1 mm apart from the optic nerve, partial to complete volume-sparing of the optic nerve head could be achieved. In 95.5% of this subgroup, the vitality of the optic nerve and vision could be preserved by the multimodality-treatment approach (mean follow-up: 18 months (7.5-36 months)). The advanced technology of stereotactic radiotherapy demonstrated the achievability of steep dose gradients around the high-dose volume, with 4D-IG-VMAT dose application. These results enforce IG-VMAT-SRS followed by resection as one of the major therapeutic options for patients with large intraocular melanoma. The combination of 4D-IG high-precision SRS and resection provides an effective treatment for large intraocular melanoma, with few side effects, and enables an eye bulb and even vision preserving modus operandi.

5.
Sci Rep ; 12(1): 16261, 2022 09 28.
Article in English | MEDLINE | ID: mdl-36171444

ABSTRACT

Biliary-tract-carcinomas (BTC), pancreatic-ductal-adenocarcinomas (PDAC) and adenoidcystic-carcinomas (AC) have in common that they are traditionally treated with large clinical-target-volumes (CTV). The aim of this study is to examine the impact of pretreatment-[68Ga]FAPI-PET/CT on target-volume-definition and posttreatment-[68Ga]FAPI-PET/CT-response-assessment for BTC-, PDAC- and AC-patients referred to radiation-therapy. All consecutive BTC-, PDAC-, and AC-patients who received pretreatment-[68Ga]FAPI-PET/CT±[18F]FDG-PET/CT were included from 01.01.2020 to 01.03.2022. MTV and SUVmax were separately generated based on [68Ga]FAPI- and [18F]FDG-PET/CT-images. A [68Ga]FAPI- and [18F]FDG-based-CTV was defined. Treatment-plans were compared. Treatment-response was reassessed by a second [68Ga]FAPI-PET/CT and [18F]FDG-PET/CT after treatment-completion. Intermodality comparison of lesion-to-background-ratios [SUVmax_lesion/SUVmean_background] for individual timepoints t1 and t2 revealed significant higher values for [68Ga]FAPI compared to [18F]FDG (t1, p = 0.008; t2, p = 0.005). Intermodality comparison of radiation-therapy-plans showed that [68Ga]FAPI-based planning resulted in D100% = 97.2% and V95% = 98.8% for the [18F]FDG-MTV. [18F]FDG-based-planning resulted in D100% = 35.9% and V95% = 78.1% for [68Ga]FAPI-MTV. [18F]FDG-based-planning resulted only in 2 patients in V95% > 95% for [68Ga]FAPI-MTV, and in 1 patient in D100% > 97% for [68Ga]FAPI-MTV. GTV-coverage in terms of V95% was 76.4% by [18F]FDG-based-planning and 99.5% by [68Ga]FAPI-based-planning. Pretreatment [68Ga]FAPI-PET/CT enhances radiation-treatment-planning in this particular group of patients. While perilesional and tumoral follow-up [18F]FDG-uptake behaved uniformly, perilesional and tumoral reaction may differ in follow-up [68Ga]FAPI-imaging. Complementary [68Ga]FAPI- and [18F]FDG-imaging enhance treatment-response-assessment.


Subject(s)
Biliary Tract , Carcinoma, Adenoid Cystic , Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Fluorodeoxyglucose F18 , Gallium Radioisotopes , Humans , Positron Emission Tomography Computed Tomography/methods , Pancreatic Neoplasms
6.
Front Oncol ; 12: 870432, 2022.
Article in English | MEDLINE | ID: mdl-36713497

ABSTRACT

Purpose: This study aimed to assess interfraction stability of the delivered dose distribution by exhale-gated volumetric modulated arc therapy (VMAT) or intensity-modulated arc therapy (IMAT) for lung cancer and to determine dominant prognostic dosimetric and geometric factors. Methods: Clinical target volume (CTVPlan) from the planning CT was deformed to the exhale-gated daily CBCT scans to determine CTVi, treated by the respective dose fraction. The equivalent uniform dose of the CTVi was determined by the power law (gEUDi) and cell survival model (EUDiSF) as effectiveness measure for the delivered dose distribution. The following prognostic factors were analyzed: (I) minimum dose within the CTVi (Dmin_i), (II) Hausdorff distance (HDDi) between CTVi and CTVPlan, (III) doses and deformations at the point in CTVPlan at which the global minimum dose over all fractions per patient occurs (PDmin_global_i), and (IV) deformations at the point over all CTVi margins per patient with the largest Hausdorff distance (HDPworst). Prognostic value and generalizability of the prognostic factors were examined using cross-validated random forest or multilayer perceptron neural network (MLP) classifiers. Dose accumulation was performed using back deformation of the dose distribution from CTVi to CTVPlan. Results: Altogether, 218 dose fractions (10 patients) were evaluated. There was a significant interpatient heterogeneity between the distributions of the normalized gEUDi values (p<0.0001, Kruskal-Wallis tests). Accumulated gEUD over all fractions per patient was 1.004-1.023 times of the prescribed dose. Accumulation led to tolerance of ~20% of fractions with gEUDi <93% of the prescribed dose. Normalized Dmin >60% was associated with predicted gEUD values above 95%. Dmin had the highest importance for predicting the gEUD over all analyzed prognostic parameters by out-of-bag loss reduction using the random forest procedure. Cross-validated random forest classifier based on Dmin as the sole input had the largest Pearson correlation coefficient (R=0.897) in comparison to classifiers using additional input variables. The neural network performed better than the random forest classifier, and the gEUD values predicted by the MLP classifier with Dmin as the sole input were correlated with the gEUD values characterized by R=0.933 (95% CI, 0.913-0.948). The performance of the full MLP model with all geometric input parameters was slightly better (R=0.952) than that based on Dmin (p=0.0034, Z-test). Conclusion: Accumulated dose distributions over the treatment series were robust against interfraction CTV deformations using exhale gating and online image guidance. Dmin was the most important parameter for gEUD prediction for a single fraction. All other parameters did not lead to a markedly improved generalizable prediction. Dosimetric information, especially location and value of Dmin within the CTV i , are vital information for image-guided radiation treatment.

SELECTION OF CITATIONS
SEARCH DETAIL
...