Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Dig Liver Dis ; 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38521670

ABSTRACT

The present document constitutes Part 2 of the EoETALY Consensus Statements guideline on the diagnosis and management of eosinophilic esophagitis (EoE) developed by experts in the field of EoE across Italy (i.e., EoETALY Consensus Group). Part 1 was published as a different document, and included three chapters discussing 1) definition, epidemiology, and pathogenesis; 2) clinical presentation and natural history and 3) diagnosis of EoE. The present work provides guidelines on the management of EoE in two final chapters: 4) treatment and 5) monitoring and follow-up, and also includes considerations on knowledge gaps and a proposed research agenda for the coming years. The guideline was developed through a Delphi process, with grading of the strength and quality of the evidence of the recommendations performed according to accepted GRADE criteria.This document has received the endorsement of three Italian national societies including the Italian Society of Gastroenterology (SIGE), the Italian Society of Neurogastroenterology and Motility (SINGEM), and the Italian Society of Allergology, Asthma, and Clinical Immunology (SIAAIC). The guidelines also involved the contribution of members of ESEO Italia, the Italian Association of Families Against EoE.

2.
Dig Liver Dis ; 56(6): 951-963, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38423918

ABSTRACT

Eosinophilic esophagitis (EoE) is a chronic type 2-mediated inflammatory disease of the esophagus that represents the most common eosinophilic gastrointestinal disease. Experts in the field of EoE across Italy (i.e., EoETALY Consensus Group) including gastroenterologists, endoscopists, allergologists/immunologists, and paediatricians conducted a Delphi process to develop updated consensus statements for the management of patients with EoE and update the previous position paper of the Italian Society of Gastroenterology (SIGE) in light of recent evidence. Grading of the strength and quality of the evidence of the recommendations was performed using accepted GRADE criteria. The guideline is divided in two documents: Part 1 includes three chapters, namely 1) definition, epidemiology, and pathogenesis; 2) clinical presentation and natural history, and 3) diagnosis, while Part 2 includes two chapters: 4) treatment and 5) monitoring and follow-up. This document has received the endorsement of three Italian national societies including the SIGE, the Italian Society of Neurogastroenterology and Motility (SINGEM), and the Italian Society of Allergology, Asthma, and Clinical Immunology (SIAAIC). With regards to patients' involvement, these guidelines involved the contribution of members of ESEO Italia, the Italian Association of Families Against EoE.


Subject(s)
Eosinophilic Esophagitis , Eosinophilic Esophagitis/diagnosis , Eosinophilic Esophagitis/therapy , Humans , Italy , Consensus , Delphi Technique , Gastroenterology/standards
3.
Eur J Gastroenterol Hepatol ; 34(11): 1121-1124, 2022 11 01.
Article in English | MEDLINE | ID: mdl-36170680

ABSTRACT

BACKGROUND: Helicobacter pylori infection is the main cause of the most frequent gastroduodenal diseases. Because its prevalence is decreasing in developed countries, gastric biopsies are negative in several patients. By measuring ammonium in the gastric juice, EndoFaster allows to exclude H. pylori infection during endoscopy. This study aimed to assess the accuracy of device versions working with either 6 ml or 3 ml of gastric juice. STUDY DESIGN: This prospective study involved 12 endoscopic units. During endoscopy, EndoFaster testing was performed and standard five gastric biopsies were taken. The accuracy was calculated by considering histological assessment as the gold standard for H. pylori diagnosis. RESULTS: Gastric juice analysis was attempted in 1279 patients, but it failed in 131 (15.5%) and in 10 (2.3%), with the 6 ml and the 3 ml device, respectively (P < 0.001). Overall, EndoFaster detected H. pylori infection with an 86.3% sensitivity, 83.3% specificity, 52.7% positive predictive value, 96.6% negative predictive value and 83.8% accuracy. The performance was not affected either by ongoing proton pump inhibitor therapy or a previous H. pylori eradication. No significant difference in accuracy emerged between the two versions of the device. CONCLUSION: The novel version of the EndoFaster device operating with 3 ml gastric juice may be performed in virtually all patients, and it allows excluding H. pylori infection with a very high accuracy. Gastric biopsies can be avoided in a definite portion of cases without endoscopic lesions or other clinical indications.


Subject(s)
Ammonium Compounds , Helicobacter Infections , Helicobacter pylori , Ammonium Compounds/therapeutic use , Gastric Juice , Helicobacter Infections/diagnosis , Helicobacter Infections/drug therapy , Humans , Prospective Studies , Proton Pump Inhibitors/therapeutic use
4.
Dig Liver Dis ; 54(12): 1646-1648, 2022 12.
Article in English | MEDLINE | ID: mdl-35794064

ABSTRACT

BACKGROUND: In patients with atrophic gastritis involving gastric body mucosa the pH value of gastric juice is distinctly increased, so that pH assessment would allow predict this precancerous lesion. We tested whether EndoFaster® - a device allowing real-time pH measure and H. pylori diagnosis - may optimize the need of taking gastric biopsies. METHODS: In this prospective, multicentre study, the accuracy of EndoFaster® for ruling out gastric atrophy involving corporal mucosa was assessed. Real-time pH and ammonium determination was performed by aspirating 3-6 ml gastric juice during endoscopy. Histology performed on 5 standard gastric biopsies was used as gold standard. RESULTS: A total of 1008 consecutive patients were observed in 12 centres. At histology, gastric body mucosa atrophy/metaplasia was detected in 65 (6.4%) cases, and a pH value >4.5 in the gastric juice was observed in 150 patients. The values of EndoFaster® performance in predicting the presence of atrophic gastritis were as follow: 51% sensitivity, 84% specificity, 18% PPV, 96% NPV, and 82% accuracy. The NPV value was not distinctly affected by neither ongoing proton pump inhibitor therapy nor H. pylori infection. By considering also data of ammonium concentrations, the values of EndoFaster® in detecting extensive atrophy on gastric mucosa were 74% sensitivity, 84% specificity, 24% PPV, 98% NPV, and 83% accuracy. CONCLUSION: The very high NPV of EndoFaster® might allow to safely rule out presence of atrophic gastritis, reducing the need of taking gastric biopsies in unselected patients managed in clinical practice.


Subject(s)
Ammonium Compounds , Gastritis, Atrophic , Helicobacter Infections , Helicobacter pylori , Humans , Gastritis, Atrophic/diagnosis , Gastritis, Atrophic/pathology , Prospective Studies , Helicobacter Infections/diagnosis , Helicobacter Infections/drug therapy , Gastric Juice , Gastric Mucosa/pathology , Atrophy/pathology , Hydrogen-Ion Concentration , Ammonium Compounds/therapeutic use
5.
J Clin Pathol ; 75(8): 572-574, 2022 Aug.
Article in English | MEDLINE | ID: mdl-33975912

ABSTRACT

Helicobacter pylori is the most frequent cause of chronic active gastritis (CAG), namely the first step for gastric cancer development. When infection is not detected at histology, another test is advised. EndoFaster is novel device that reveal the presence of H. pylori by determining ammonium concentration in the gastric juice during endoscopy. We evaluated whether this test may improve etiological diagnosis in CAG patients. In 595 consecutive patients who underwent upper endoscopy gastric juice was analysed with EndoFaster and standard biopsies were taken. CAG with typical bacteria was detected in 102 (17.1%) patients, and CAG without H. pylori was found in 36 (6.3%) cases. EndoFaster detected the infection in 22 (61.1%) of these patients. Neither ongoing proton pump inhibitor therapy nor previous eradication therapy affect the test accuracy. By using EndoFaster, another test to search for the infection in H. pylori-negative CAG patients may be avoided in more than 60% of cases, impacting on both patients discomfort and health resources use.


Subject(s)
Gastritis, Atrophic , Gastritis , Helicobacter Infections , Helicobacter pylori , Gastric Juice/microbiology , Gastritis/diagnosis , Gastritis/microbiology , Gastritis, Atrophic/etiology , Gastritis, Atrophic/microbiology , Helicobacter Infections/microbiology , Humans
6.
Dig Liver Dis ; 53(6): 772-775, 2021 06.
Article in English | MEDLINE | ID: mdl-33676857

ABSTRACT

BACKGROUND/AIM: H. pylori plays a major role in gastroduodenal diseases. Since its incidence is decreasing in developed countries, gastric biopsies were negative in several patients managed in clinical practice. We tested whether EndoFasterⓇ - a device allowing real-time H. pylori detection by gastric juice analysis - may optimize the need of biopsies. METHODS: In this prospective, multicentre study, the accuracy of EndoFasterⓇ for H. pylori detection was computed by using histology of gastric biopsies as a gold standard. RESULTS: Data of 525 consecutive patients were available, including 90 (17.1%) patients with infection. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy of EndoFasterⓇ were 87%, 84%, 53%, 97% and 85%, respectively. The overall accuracy of test was not affected neither by ongoing proton pump inhibitor therapy nor by previous eradication therapy. By using EndoFasterⓇ in our series, biopsy sampling could have been eventually avoided in a total of 279 patients, accounting for a reduction of 42.3%, accepting the risk of only 8 false negative cases. CONCLUSIONS: The very high NPV of EndoFasterⓇ might allow to safely halve the need of taking gastric biopsies in unselected patients managed in clinical practice, avoiding an unavailing consume of health resources.


Subject(s)
Endoscopy, Digestive System/instrumentation , Gastric Juice/microbiology , Helicobacter Infections/diagnosis , Helicobacter pylori/isolation & purification , Adult , Aged , Aged, 80 and over , Female , Humans , Italy , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , ROC Curve
7.
Eur J Oral Sci ; 123(3): 208-14, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25735897

ABSTRACT

The aim of this study was to investigate the degree of conversion, monomer release, and cytotoxicity of two dual-cure resin cements (Cement-One and SmartCem2), light-cured across two indirect restorative materials in an attempt to simulate in vitro the clinical conditions. The results obtained show that the degree of conversion was influenced by both barriers, but the effect of the composite material was greater than that of the ceramic one. The amount of monomers released from the polymerized materials in the absence of barriers was significantly lower than that released in the presence of either the ceramic or the composite barrier. However, a higher amount of monomers was released in the presence of the ceramic barrier. All materials, in all the experimental conditions employed, induced slight cytotoxicity (5-10%) on human pulp cells. Our examinations showed that the two resin cements had similar chemical and biological properties. The decreased degree of conversion of the dual-curing self-adhesive composite showed that the light-curing component of these materials has an important role in the polymerization process. In clinical practice, it is therefore important to pay attention to the thickness of the material used for the reconstruction.


Subject(s)
Resin Cements/chemistry , Self-Curing of Dental Resins/methods , Bisphenol A-Glycidyl Methacrylate/chemistry , Cells, Cultured , Ceramics/chemistry , Composite Resins/chemistry , Dental Materials/chemistry , Dental Pulp/cytology , Dental Pulp/drug effects , Humans , Light-Curing of Dental Adhesives/methods , Materials Testing , Methacrylates/chemistry , Polyethylene Glycols/chemistry , Polymerization , Polymethacrylic Acids/chemistry , Polyurethanes/chemistry , Resin Cements/toxicity , Spectrophotometry/instrumentation , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...