Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Bioanal Chem ; 411(10): 1957-1977, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30830245

ABSTRACT

Untargeted analysis of a composite house dust sample has been performed as part of a collaborative effort to evaluate the progress in the field of suspect and nontarget screening and build an extensive database of organic indoor environment contaminants. Twenty-one participants reported results that were curated by the organizers of the collaborative trial. In total, nearly 2350 compounds were identified (18%) or tentatively identified (25% at confidence level 2 and 58% at confidence level 3), making the collaborative trial a success. However, a relatively small share (37%) of all compounds were reported by more than one participant, which shows that there is plenty of room for improvement in the field of suspect and nontarget screening. An even a smaller share (5%) of the total number of compounds were detected using both liquid chromatography-mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS). Thus, the two MS techniques are highly complementary. Most of the compounds were detected using LC with electrospray ionization (ESI) MS and comprehensive 2D GC (GC×GC) with atmospheric pressure chemical ionization (APCI) and electron ionization (EI), respectively. Collectively, the three techniques accounted for more than 75% of the reported compounds. Glycols, pharmaceuticals, pesticides, and various biogenic compounds dominated among the compounds reported by LC-MS participants, while hydrocarbons, hydrocarbon derivatives, and chlorinated paraffins and chlorinated biphenyls were primarily reported by GC-MS participants. Plastics additives, flavor and fragrances, and personal care products were reported by both LC-MS and GC-MS participants. It was concluded that the use of multiple analytical techniques was required for a comprehensive characterization of house dust contaminants. Further, several recommendations are given for improved suspect and nontarget screening of house dust and other indoor environment samples, including the use of open-source data processing tools. One of the tools allowed provisional identification of almost 500 compounds that had not been reported by participants.

2.
Anal Bioanal Chem ; 407(21): 6237-55, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25976391

ABSTRACT

In this article, a dataset from a collaborative non-target screening trial organised by the NORMAN Association is used to review the state-of-the-art and discuss future perspectives of non-target screening using high-resolution mass spectrometry in water analysis. A total of 18 institutes from 12 European countries analysed an extract of the same water sample collected from the River Danube with either one or both of liquid and gas chromatography coupled with mass spectrometry detection. This article focuses mainly on the use of high resolution screening techniques with target, suspect, and non-target workflows to identify substances in environmental samples. Specific examples are given to emphasise major challenges including isobaric and co-eluting substances, dependence on target and suspect lists, formula assignment, the use of retention information, and the confidence of identification. Approaches and methods applicable to unit resolution data are also discussed. Although most substances were identified using high resolution data with target and suspect-screening approaches, some participants proposed tentative non-target identifications. This comprehensive dataset revealed that non-target analytical techniques are already substantially harmonised between the participants, but the data processing remains time-consuming. Although the objective of a "fully-automated identification workflow" remains elusive in the short term, important steps in this direction have been taken, exemplified by the growing popularity of suspect screening approaches. Major recommendations to improve non-target screening include better integration and connection of desired features into software packages, the exchange of target and suspect lists, and the contribution of more spectra from standard substances into (openly accessible) databases. Graphical Abstract Matrix of identification approach versus identification confidence.


Subject(s)
Mass Spectrometry/methods , Water/analysis , Chromatography, Gas , Chromatography, Liquid
3.
Anal Bioanal Chem ; 377(1): 32-8, 2003 Sep.
Article in English | MEDLINE | ID: mdl-12750870

ABSTRACT

A laboratory reference material (LRM) was prepared from Brazil nuts (Bertholletia excelsa) for quality control (QC) purposes of selenium speciation. The preparation of this LRM led through the usual operation steps applied during routine reference material production from biota samples-preparation of the raw material, homogenisation, storage design, checking of homogeneity, microbiological status and possible irradiation effects, and monitoring the species stability vs time at different storage temperatures. The selenium speciation studies to check species stability were carried out on a HPLC-UV-HG-AFS measurement set-up. Special attention was paid to the correct identification of selenium species by applying independent HPLC separation techniques (ion-pairing and anion-exchange chromatography). The concentration of selenomethionine (SeMet) and total Se content were quantified (79.9 microg g(-1) (calculated as Se) and 82.9 microg g(-1), respectively). The homogeneity and stability of this candidate reference material passed the relevant tests recommended by Bureau Communautaire de Référence (BCR).

SELECTION OF CITATIONS
SEARCH DETAIL
...