Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 188
Filter
1.
Ophthalmology ; 130(7): e25-e26, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37041094
2.
Ophthalmology ; 129(12): 1357-1367, 2022 12.
Article in English | MEDLINE | ID: mdl-35835336

ABSTRACT

PURPOSE: To describe postoperative complications encountered in the Primary Tube Versus Trabeculectomy (PTVT) Study during 5 years of follow-up. DESIGN: Multicenter randomized clinical trial. PARTICIPANTS: A total of 242 eyes of 242 patients with medically uncontrolled glaucoma and no previous incisional ocular surgery, including 125 patients in the tube group and 117 patients in the trabeculectomy group. METHODS: Patients were enrolled at 16 clinical centers and randomly assigned to treatment with a tube shunt (350-mm2 Baerveldt glaucoma implant) or trabeculectomy with mitomycin C (MMC, 0.4 mg/ml for 2 minutes). MAIN OUTCOME MEASURES: Surgical complications, reoperations for complications, visual acuity, and cataract progression. RESULTS: Early postoperative complications occurred in 24 patients (19%) in the tube group and 40 patients (34%) in the trabeculectomy group (P = 0.013). Late postoperative complications developed in 27 patients (22%) in the tube group and 32 patients (27%) in the trabeculectomy group (P = 0.37). Serious complications producing vision loss and/or requiring a reoperation were observed in 3 patients (2%) in the tube group and 9 patients (8%) in the trabeculectomy group (P = 0.11). Cataract progression was seen in 65 patients (52%) in the tube group and 52 patients (44%) in the trabeculectomy group (P = 0.30). Surgical complications were not associated with a higher rate of treatment failure (P = 0.61), vision loss (P = 1.00), or cataract progression (P = 0.77) CONCLUSIONS: A large number of surgical complications were observed in the PTVT Study, but most were transient and self-limited. The incidence of early postoperative complications was higher following trabeculectomy with MMC than with tube shunt surgery. The rates of late postoperative complications, serious complications, and cataract progression were similar with both surgical procedures after 5 years of follow-up. Surgical complications did not increase the risk of treatment failure, vision loss, or cataract progression.


Subject(s)
Cataract , Glaucoma Drainage Implants , Glaucoma , Trabeculectomy , Humans , Trabeculectomy/methods , Follow-Up Studies , Intraocular Pressure , Alkylating Agents , Treatment Outcome , Glaucoma/surgery , Mitomycin , Postoperative Complications/surgery , Blindness/surgery
3.
Ophthalmology ; 129(12): 1344-1356, 2022 12.
Article in English | MEDLINE | ID: mdl-35835337

ABSTRACT

PURPOSE: To report 5-year treatment outcomes in the Primary Tube Versus Trabeculectomy (PTVT) Study. DESIGN: Multicenter randomized clinical trial. PARTICIPANTS: A total of 242 eyes of 242 patients with medically uncontrolled glaucoma and no previous incisional ocular surgery, including 125 patients in the tube group and 117 patients in the trabeculectomy group. METHODS: Patients were enrolled at 16 clinical centers and randomly assigned to treatment with a tube shunt (350-mm2 Baerveldt glaucoma implant) or trabeculectomy with mitomycin C (MMC) (0.4 mg/ml for 2 minutes). MAIN OUTCOME MEASURES: The primary outcome measure was the rate of surgical failure, defined as intraocular pressure (IOP) > 21 mmHg or reduced < 20% from baseline, IOP ≤ 5 mmHg, reoperation for glaucoma, or loss of light perception. Secondary outcome measures included IOP, glaucoma medical therapy, and visual acuity. RESULTS: The cumulative probability of failure after 5 years of follow-up was 42% in the tube group and 35% in the trabeculectomy group (P = 0.21; hazard ratio = 1.31; 95% confidence interval = 0.86-2.01). At 5 years, IOP (mean ± standard deviation) was 13.4 ± 3.5 mmHg in the tube group and 13.0 ± 5.2 mmHg in the trabeculectomy group (P = 0.52), and the number of glaucoma medications (mean ± standard deviation) was 2.2 ± 1.3 in the tube group and 1.3 ± 1.4 in the trabeculectomy group (P < 0.001). CONCLUSIONS: Trabeculectomy with MMC and tube shunt surgery produced similar IOPs after 5 years of follow-up in the PTVT Study, but fewer glaucoma medications were required after trabeculectomy. No significant difference in the rate of surgical failure was observed between the 2 surgical procedures at 5 years.


Subject(s)
Glaucoma Drainage Implants , Glaucoma , Trabeculectomy , Humans , Trabeculectomy/methods , Follow-Up Studies , Glaucoma/surgery , Intraocular Pressure , Mitomycin , Treatment Outcome
4.
Ophthalmol Ther ; 11(4): 1517-1537, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35643967

ABSTRACT

INTRODUCTION: This study evaluated the intraocular pressure (IOP)-lowering efficacy and safety of a single intracameral administration of bimatoprost implant 10 µg in adults with open-angle glaucoma or ocular hypertension. METHODS: Two identically designed, randomized, 20-month, parallel-group, phase 3 clinical trials (one study eye/patient) compared three administrations of 10- or 15-µg bimatoprost implant (day 1, weeks 16 and 32) with twice-daily topical timolol maleate 0.5%. An open-label, 24-month, phase 1/2 clinical trial compared one or two implants administered in the study eye with once-daily topical bimatoprost 0.03% in the fellow eye. Separate analyses of the pooled phase 3 and phase 1/2 study datasets evaluated outcomes in the 10-µg bimatoprost implant and comparator treatment arms after a single implant administration, up to the time of implant re-administration or rescue with IOP-lowering medication. RESULTS: In the phase 3 studies, 10-µg bimatoprost implant single administration demonstrated IOP reductions (hour 0) of 4.9-7.0 mmHg through week 15 from a mean (standard deviation, SD) baseline IOP of 24.5 (2.6) mmHg (n = 374); IOP in the topical timolol BID group was reduced by 6.0-6.3 mmHg from a mean (SD) baseline IOP of 24.5 (2.6) mmHg (n = 373). In the phase 1/2 study (n = 21), median time to use of additional IOP-lowering treatment (Kaplan-Meier analysis) was 273 days (approximately 9 months), and 5 of 21 enrolled patients (23.8%) required no additional IOP-lowering treatment up to 24 months after single administration. In each study, after a single implant administration there were no reports of corneal edema, corneal endothelial cell loss, or corneal touch, and no patients had 20% or greater loss in corneal endothelial cell density. CONCLUSIONS: Bimatoprost implant single administration lowers IOP and has a favorable safety profile. Additional studies are needed to further evaluate the duration of effect and factors predicting long-term IOP lowering after a single implant administration. TRIAL REGISTRATION NUMBERS: ClinicalTrials.gov NCT02247804, NCT02250651, and NCT01157364.

5.
Clin Ophthalmol ; 16: 2069-2078, 2022.
Article in English | MEDLINE | ID: mdl-35770248

ABSTRACT

Purpose: We aimed to evaluate the effectiveness and safety of a virtual eye assessment triage system implemented in response to COVID-19. Patients and Methods: We conducted a retrospective cross-sectional study using a consecutive sample of all virtual assessments conducted from March 24 to June 7, 2020 at a single ophthalmology center in Toronto, ON, Canada. Visual acuity and smartphone photographs were uploaded to an electronic assessment website. All patients were virtually triaged to an email or phone consult. Patient outcomes and satisfaction were assessed with a quality assurance survey. Primary outcome measures were the incidence of unplanned additional in-person visits and changes in treatment. Results: We performed 1535 virtual assessments. Of the triage pathways, 15% received an email consult only and 85% received a phone consult. Subsequently, 15% required an in-person assessment, 3% were referred elsewhere, and 0.1% were sent to the emergency. Presentations were most commonly cornea (52%) and retina (25%). They were non-urgent in 68% of cases and no pharmacologic treatment was required for 49%. Of 397 patients that responded out of 653 patients surveyed, 4% had an unplanned additional visit to the emergency, after which two patients underwent urgent retinal surgery and one patient underwent urgent glaucoma surgery. Two patients (0.5%) had a minor change in treatment. Conclusion: As routine regular in-person visits were not possible during the COVID-19 lockdown, virtual eye assessments provided an opportunity to triage patients. Virtual assessments have the potential to reduce in-person visits, but caution must be exercised to not miss vision-threatening conditions.

6.
Am J Ophthalmol ; 240: 217-224, 2022 08.
Article in English | MEDLINE | ID: mdl-35288073

ABSTRACT

PURPOSE: To identify the risk factors associated with failure of tube shunt surgery. DESIGN: Pooled analysis of 3 prospective multicenter, randomized clinical trials. METHODS: A total of 621 patients with medically uncontrolled glaucoma were enrolled, including 276 from the Ahmed Baerveldt Comparison Study, 238 from the Ahmed Versus Baerveldt Study, and 107 from the tube group of the Tube Versus Trabeculectomy Study. Patients were randomized to treatment with an Ahmed glaucoma valve (model FP7) or Baerveldt glaucoma implant (model 101-350). The associations between baseline risk factors and tube shunt failure were assessed using a Cox proportional hazards regression model. The primary outcome measure was the rate of surgical failure defined as intraocular pressure (IOP) > 21 mmHg or reduced < 20% from baseline, IOP ≤ 5 mmHg, loss of light perception vision, reoperation for glaucoma, or removal of implant. RESULTS: The cumulative probability of failure after tube shunt surgery was 38.3% after 5 years. In multivariable analyses, baseline factors that predicted tube shunt failure included preoperative IOP (≤ 21 mmHg compared to IOP > 21 and ≤ 25 mmHg; HR, 2.34; 95% CI, 1.52-3.61; P < .001), neovascular glaucoma (HR, 1.79; 95% CI, 1.28-2.52; P = .001), randomized treatment (for Ahmed glaucoma valve; HR, 1.36; 95% CI, 1.04-1.78; P = .025), and age (for 10 year decrease in age; HR, 1.19; 95% CI, 1.09-1.31; P < .001). CONCLUSIONS: Lower preoperative IOP, neovascular glaucoma, Ahmed implantation, and younger age were predictors of tube shunt failure. This Study provides the largest prospectively collected dataset on tube shunt surgery.


Subject(s)
Glaucoma Drainage Implants , Glaucoma, Neovascular , Glaucoma , Data Analysis , Follow-Up Studies , Glaucoma/surgery , Glaucoma, Neovascular/surgery , Humans , Intraocular Pressure , Postoperative Complications/surgery , Prospective Studies , Prosthesis Implantation , Risk Factors , Treatment Outcome , Visual Acuity
7.
J Glaucoma ; 29(12): e130-e134, 2020 12.
Article in English | MEDLINE | ID: mdl-32910008

ABSTRACT

PURPOSE: To demonstrate canalogram patterns observed when trypan blue tracer is combined with oculoviscoelastic device during ab interno canaloplasty, and discuss surgical results and potential implications for diagnosis, prognosis, and treatment. METHODS: This is a retrospective small case series study. RESULTS: The authors performed this procedure on 5 patients with informed consent with 4 to 18 months of follow-up. All procedures have been complication free. The average preoperative intraocular pressure was 16.4 mm Hg with an average number of topical glaucoma medications being equal to 3.6. Postoperatively, the average intraocular pressure for the group was reduced to 13 mm Hg with a concurrent drop in the average number of topical medications used equaling 1.8. CONCLUSIONS: Currently, there are limited practical options to evaluate the patency of the aqueous outflow system in our patients. The primary purpose of this paper is to describe canalogram patterns observed during ab interno canaloplasty with trypan blue. This technique may allow us to further our understanding of the aqueous outflow system and its role in the underlying pathophysiology of glaucoma. Further research is required to evaluate the prognostic and diagnostic significance of this technique.


Subject(s)
Aqueous Humor/physiology , Coloring Agents/administration & dosage , Glaucoma, Open-Angle/surgery , Phlebography , Trabeculectomy/methods , Trypan Blue/administration & dosage , Aged , Female , Follow-Up Studies , Glaucoma, Open-Angle/physiopathology , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Retrospective Studies , Tonometry, Ocular , Treatment Outcome , Viscosupplements
8.
Med Devices (Auckl) ; 13: 213-221, 2020.
Article in English | MEDLINE | ID: mdl-32765127

ABSTRACT

PURPOSE: Our aim was to evaluate and compare the clinical outcomes after implantation of the silicone-plate (model FP7) and porous polyethylene-plate (model M4) Ahmed Glaucoma Valves. PATIENTS AND METHODS: This was a prospective, multicenter, comparative series. A total of 52 eyes (52 patients) were treated with either the silicone or porous plate Ahmed Glaucoma Valve implant. Hypertensive phase was defined as intraocular pressure >21 mmHg during the first 3 months postoperatively. Success was defined as 5 mmHg ≤intraocular pressure ≤21 mmHg (with or without additional glaucoma medications), without loss of light perception and without additional glaucoma procedures. Patients were monitored for 1 year after surgery. RESULTS: The pre-operative intraocular pressure was 29.9 ± 6.6 mmHg and 33.8 ± 10.5 in the silicone-plate and porous-plate groups, respectively (P = 0.118). At 12 months after surgery, the mean intraocular pressure was 13.6 ± 4.7 mmHg in the silicone-plate group and 17.9 ± 10.9 mmHg in the porous-plate group (P = 0.141). The mean number of glaucoma medications at 12 months was 1.64 ± 1.40 mmHg and 1.89 ± 1.54 mmHg in the silicone- and porous-plate groups, respectively (P = 0.605). Hypertensive phase was not significantly different in the two groups (50.0% of the silicone-plate and 57.7% of the porous-plate groups, P = 0.578). At 12 months after surgery, the percent success for the silicone-plate and porous-plate groups was 88.5% and 53.8%, respectively (P = 0.005). Complications were similar in the two groups. CONCLUSION: The porous-plate Ahmed Glaucoma Valve showed similar average intraocular pressure reduction compared with the silicone-plate model. At 12 months after surgery, there was a significantly lower success rate in the porous-plate compared with the silicone-plate group.

12.
Ophthalmology ; 127(3): 333-345, 2020 03.
Article in English | MEDLINE | ID: mdl-31727428

ABSTRACT

PURPOSE: To report 3-year results of the Primary Tube Versus Trabeculectomy (PTVT) Study. DESIGN: Unmasked multicenter randomized clinical trial. PARTICIPANTS: Two hundred forty-two eyes of 242 patients with medically uncontrolled glaucoma and no previous incisional ocular surgery, including 125 in the tube group and 117 in the trabeculectomy group. METHODS: Patients were enrolled at 16 clinical centers and were assigned randomly to treatment with a tube shunt (350-mm2 Baerveldt glaucoma implant) or trabeculectomy with mitomycin C (MMC; 0.4 mg/ml for 2 minutes). MAIN OUTCOME MEASURES: The primary outcome measure was the rate of surgical failure, defined as intraocular pressure (IOP) of more than 21 mmHg or reduced less than 20% from baseline, IOP of 5 mmHg or less, reoperation for glaucoma, or loss of light perception vision. Secondary outcome measures included IOP, glaucoma medical therapy, visual acuity, and surgical complications. RESULTS: The cumulative probability of failure after 3 years of follow-up was 33% in the tube group and 28% in the trabeculectomy group (P = 0.17; hazard ratio, 1.39; 95% confidence interval, 0.9-2.2). Mean ± standard deviation IOP was 14.0±4.2 mmHg in the tube group and 12.1±4.8 mmHg in the trabeculectomy group at 3 years (P = 0.008), and the number of glaucoma medications was 2.1±1.4 in the tube group and 1.2±1.5 in the trabeculectomy group (P < 0.001). Serious complications requiring reoperation or producing loss of 2 or more Snellen lines developed in 3 patients (2%) in the tube group and 9 patients (8%) in the trabeculectomy group (P = 0.11). CONCLUSIONS: There was no significant difference in the rate of surgical failure between the 2 surgical procedures at 3 years. Trabeculectomy with MMC achieved lower IOP with use of fewer glaucoma medications compared with tube shunt surgery after 3 years of follow-up in the PTVT Study. Serious complications producing vision loss or requiring reoperation occurred with similar frequency after both surgical procedures.


Subject(s)
Glaucoma Drainage Implants , Glaucoma/surgery , Trabeculectomy/methods , Adult , Aged , Aged, 80 and over , Alkylating Agents/administration & dosage , Female , Follow-Up Studies , Humans , Intraocular Pressure , Male , Middle Aged , Mitomycin/administration & dosage , Reoperation , Visual Acuity
13.
Front Pharmacol ; 10: 801, 2019.
Article in English | MEDLINE | ID: mdl-31427961

ABSTRACT

Considering the significance of biological and eco-friendly nanomaterials, in the present study, we have synthesized silver nanoparticles from the exopolysaccharide of recently recovered bacterial strain CEES51 from the Red Sea coastal area of Jeddah, Saudi Arabia. 16S ribosomal RNA gene sequencing was used to characterize the isolated bacteria, and it was identified as Mesoflavibacter zeaxanthinifaciens and assigned an accession number MH707257.1 GenBank. The bacterial strain is an excellent exopolysaccharide producer and survived at hypersaline (30%) and high-temperature (50°C) conditions. The bacterial exopolysaccharides were employed for the fabrication of silver nanoparticles at room temperature. UV-visible spectrophotometer optimized the synthesized nanoparticles, and their size was determined by Nanophox particle size analyzer and dynamic light scattering. Additionally, the X-ray powder diffraction and Fourier-transform infrared spectroscopy studies also approved its crystalline nature and the involvement of organic functional groups in their formation. The synthesized nanomaterials were tested for their antibacterial and antibiofilm properties against pathogenic microorganisms Bacillus subtilis and methicillin-resistant Staphylococcus aureus. The antimicrobial property showed time, and dose-dependent response with a maximum of zone inhibition was observed at around 22 and 18 mm at a dose of 50 µg/well against B. subtilis and S. aureus and a minimum inhibitory concentration of 8 and 10 µg/ml, respectively. Furthermore, the synthesized silver nanoparticles possessed a substantial antibiofilm property and were also found to be biocompatible as depicted by red blood cell lysis assay and their interaction with peripheral blood mononuclear cells and human embryonic kidney 293 cells. Therefore, Mesoflavibacter zeaxanthinifaciens is found to be an excellent source for exopolysaccharide synthesis that assists in the silver nanoparticle production.

15.
Clin Exp Ophthalmol ; 47(5): 581-587, 2019 07.
Article in English | MEDLINE | ID: mdl-30578661

ABSTRACT

IMPORTANCE: The transscleral XEN Glaucoma Gel Microstent (XEN-GGM, Allergan Plc., Parsippany, New Jersey) is implanted by a minimally invasive ab interno technique. BACKGROUND: The present study aims to assess the long-term clinical outcomes in patients after XEN-GGM implantation. DESIGN: This prospective, non-randomized, multi-centred study was conducted in three countries (Austria, Canada and Germany). PARTICIPANTS: Sixty-four consecutive eyes of 64 patients with open angle glaucoma received the XEN-GGM (63 µm) without Mitomycin C. Thirty-five (55%) were solo procedures, and 29 (45%) were combined with cataract surgery. METHODS: Visits were planned at baseline, 6 months, 1, 2, 3 and 4 years postoperatively. MAIN OUTCOME MEASURES: The main outcome measures were mean intraocular pressure (IOP), mean number of IOP lowering medication. Secondary outcome parameters were: visual acuity, visual fields and complete surgical failure (defined as presence of a secondary IOP lowering procedure or loss of light perception) at 4 years, postoperatively. RESULTS: Mean best-medicated baseline IOP was 22.5 ± 4.2 mmHg and decreased significantly to 13.4 ± 3.1 mmHg 4 years postoperatively (-40%, n = 34, P < 0.001). Mean number of IOP lowering medication decreased significantly from 2.4 ± 1.3 preoperatively to 1.2 ± 1.3 (-50%, n = 34, P < 0.001) postoperatively. Visual field mean deviation showed no significant change between preoperative and postoperative examinations. Complete surgical failure rate per year was 10%. CONCLUSIONS AND RELEVANCE: The XEN-GGM resulted in lower IOP and a reduction in medications from baseline over 4 years of follow-up. There was no detectable decrease in visual fields over the study. The surgical failure rate is comparable to other filtration surgeries.


Subject(s)
Glaucoma Drainage Implants , Glaucoma, Open-Angle/surgery , Stents , Adolescent , Adult , Aged , Aged, 80 and over , Cataract Extraction , Female , Glaucoma, Open-Angle/physiopathology , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Minimally Invasive Surgical Procedures , Prospective Studies , Prosthesis Implantation , Tonometry, Ocular , Treatment Outcome , Visual Acuity/physiology , Visual Fields/physiology , Young Adult
16.
Anaesth Intensive Care ; 46(6): 572-574, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30447665

ABSTRACT

We report a case of serious neurologic injury due to inadvertent epidural injection of 8 ml of the antiseptic 2% chlorhexidine in 70% alcohol during a procedure aimed to relieve the pain of labour. This resulted in immediate severe back pain, progressive tetraparesis and sphincter dysfunction caused by damage to the spinal cord and nerve roots. Subacute hydrocephalus necessitated drainage, but cranial nerve and cognitive function were spared. Magnetic resonance imaging documented marked abnormality of the spinal cord and surrounding leptomeninges. In the ensuing eight years, there has been clinical and electrophysiological evidence of partial recovery, but neurologic deficit remains severe.


Subject(s)
Anti-Infective Agents, Local/adverse effects , Arachnoiditis/chemically induced , Chlorhexidine/adverse effects , Medical Errors/adverse effects , Adult , Alcohols/administration & dosage , Anti-Infective Agents, Local/administration & dosage , Arachnoiditis/diagnostic imaging , Chlorhexidine/administration & dosage , Female , Follow-Up Studies , Humans , Injections, Epidural , Magnetic Resonance Imaging , Pregnancy , Spinal Cord/diagnostic imaging , Spinal Cord/pathology
17.
J Glaucoma ; 27(7): 585-591, 2018 07.
Article in English | MEDLINE | ID: mdl-29762270

ABSTRACT

PURPOSE: To develop a descriptive system for a glaucoma-specific preference-based health-related quality of life (HRQoL) instrument: the Health Utility for Glaucoma (HUG-5). METHODS: The descriptive system was developed in 2 stages: item identification and item selection. A systematic literature review of HRQoL assessment of glaucoma was conducted using a comprehensive search strategy. Purposeful sampling was used to recruit patients with different clinical characteristics. Relevant items were presented to glaucoma patients through face-to-face, semistructured interviews. Framework methodology was applied to analyze interview content. The recurring themes identified through an iterative content analysis represented topics of most importance and relevance to patients. These themes formed the domains of the HUG-5 descriptive system. Three versions of the descriptive system, differing in explanatory detail, were pilot tested using a focus group. RESULTS: The literature review identified 19 articles which contained 266 items. These items were included for the full-text review and were used to develop an interview guide. From 12 patient interviews, 22 themes were identified and grouped into 5 domains that informed the 5 questions of the descriptive system. The HUG-5 measures visual discomfort, mobility, daily life activities, emotional well-being, and social activities. Each question has 5 response levels that range from "no problem" to "severe problem." The focus group comprised 7 additional patients unanimously preferred the version that contained detailed, specific examples to support each question. CONCLUSIONS: A 5-domain descriptive system of a glaucoma-specific preference-based instrument, the HUG-5, was developed and remains to be evaluated for validity and reliability in the glaucoma patient population.


Subject(s)
Glaucoma/psychology , Glaucoma/therapy , Patient Acceptance of Health Care , Patient Preference , Quality of Life , Aged , Female , Focus Groups , Glaucoma/epidemiology , Glaucoma/physiopathology , Humans , Intraocular Pressure , Male , Middle Aged , Patient Acceptance of Health Care/psychology , Patient Acceptance of Health Care/statistics & numerical data , Patient Preference/psychology , Patient Preference/statistics & numerical data , Reproducibility of Results , Surveys and Questionnaires
18.
Ophthalmology ; 125(5): 650-663, 2018 05.
Article in English | MEDLINE | ID: mdl-29477688

ABSTRACT

PURPOSE: To report 1-year treatment outcomes in the Primary Tube Versus Trabeculectomy (PTVT) Study. DESIGN: Multicenter, randomized clinical trial. PARTICIPANTS: Two hundred forty-two eyes of 242 patients with medically uncontrolled glaucoma and no previous incisional ocular surgery, including 125 in the tube group and 117 in the trabeculectomy group. METHODS: Patients were enrolled at 16 clinical centers and assigned randomly to treatment with a tube shunt (350-mm2 Baerveldt glaucoma implant) or trabeculectomy with mitomycin C (MMC; 0.4 mg/ml for 2 minutes). MAIN OUTCOME MEASURES: Intraocular pressure (IOP), glaucoma medical therapy, visual acuity, visual fields, surgical complications, and failure (IOP of more than 21 mmHg or reduced by less than 20% from baseline, IOP of 5 mmHg or less, reoperation for glaucoma, or loss of light perception vision). RESULTS: The cumulative probability of failure during the first year of follow-up was 17.3% in the tube group and 7.9% in the trabeculectomy group (P = 0.01; hazard ratio, 2.59; 95% confidence interval, 1.20-5.60). Mean ± standard deviation IOP was 13.8±4.1 mmHg in the tube group and 12.4±4.4 mmHg in the trabeculectomy group at 1 year (P = 0.01), and the number of glaucoma medications was 2.1±1.4 in the tube group and 0.9±1.4 in the trabeculectomy group (P < 0.001). Postoperative complications developed in 36 patients (29%) in the tube group and 48 patients (41%) in the trabeculectomy group (P = 0.06). Serious complications requiring reoperation or producing a loss of 2 Snellen lines or more occurred in 1 patient (1%) in the tube group and 8 patients (7%) in the trabeculectomy group (P = 0.03). CONCLUSIONS: Trabeculectomy with MMC had a higher surgical success rate than tube shunt implantation after 1 year in the PTVT Study. Lower IOP with use of fewer glaucoma medications was achieved after trabeculectomy with MMC compared with tube shunt surgery during the first year of follow-up. The frequency of serious complications producing vision loss or requiring reoperation was lower after tube shunt surgery relative to trabeculectomy with MMC.


Subject(s)
Glaucoma Drainage Implants , Glaucoma/surgery , Prosthesis Implantation/methods , Trabeculectomy/methods , Adult , Aged , Aged, 80 and over , Alkylating Agents/administration & dosage , Double-Blind Method , Female , Follow-Up Studies , Glaucoma/physiopathology , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Mitomycin/administration & dosage , Postoperative Complications , Reoperation , Tonometry, Ocular , Treatment Outcome , Visual Acuity/physiology , Visual Fields/physiology , Young Adult
19.
J Laryngol Otol ; 131(12): 1065-1092, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29280695

ABSTRACT

BACKGROUND: The mainstay of management of epistaxis refractory to first aid and cautery is intranasal packing. This review aimed to identify evidence surrounding nasal pack use. METHOD: A systematic review of the literature was performed using standardised methodology. RESULTS: Twenty-seven eligible articles were identified relating to non-dissolvable packs and nine to dissolvable packs. Nasal packing appears to be more effective when applied by trained professionals. For non-dissolvable packs, the re-bleed rates for Rapid Rhino and Merocel were similar, but were higher with bismuth iodoform paraffin paste packing. Rapid Rhino packs were the most tolerated non-dissolvable packs. Evidence indicates that 96 per cent of re-bleeding occurs within the first 4 hours after nasal pack removal. Limited evidence suggests that dissolvable packs are effective and well tolerated by patients. There was a lack of evidence relating to: the duration of pack use, the economic effects of pack choice and the appropriate care setting for non-dissolvable packs. CONCLUSION: Rapid Rhino packs are the best tolerated, with efficacy equivalent to nasal tampons. FloSeal is easy to use, causes less discomfort and may be superior to Merocel in anterior epistaxis cases. There is no strong evidence to support prophylactic antibiotic use.


Subject(s)
Epistaxis/therapy , Hemostatics/therapeutic use , Tampons, Surgical , Adult , Combined Modality Therapy , Electrocoagulation , First Aid , Humans , Treatment Outcome
20.
Am J Pharm Educ ; 81(8): S12, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29200460

ABSTRACT

The 2016-2017 AACP Student Affairs Standing Committee addressed charges related to recruitment to the profession of pharmacy and a national awareness campaign for pharmacy careers, as well as promotion of student wellness and stress management. The Committee report provides six recommendations to the American Association of Colleges of Pharmacy (AACP) and one proposed policy statement for the AACP House of Delegates related to recruitment to the pharmacy profession. The Committee report also provides three recommendations to AACP and one proposed policy statement for the AACP House of Delegates related to student wellness and stress management. In addition, this report provides recommendations for future AACP Student Affairs Standing Committee work.


Subject(s)
Education, Pharmacy , Schools, Pharmacy , Societies, Pharmaceutical , Students, Pharmacy , Advisory Committees , Annual Reports as Topic , Humans , Organizational Policy , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...