ABSTRACT
Worn shoes are known to contribute to slip-and-fall risk, a common cause of workplace injuries. However, guidelines for replacing shoes are not well developed. Recent experiments and lubrication theory suggest that the size of the worn region is an important contributor to the shoe tread's ability to drain fluid and therefore the under-shoe friction. This study evaluated a simple test for comparing the size of the worn region relative to a common object (AAA and AA battery) as a means of determining shoe replacement. This study consisted of three components involving slip-resistant shoes: Experiment #1: a longitudinal, mechanical, accelerated wear experiment; Experiment #2: a longitudinal experiment where the same shoes were tested after each month of worker use; and Experiment #3: a cross-sectional experiment that exposed participants to a slippery condition, while donning their own worn shoes. The COF (Experiments #1 and #2); under-shoe fluid pressure (all experiments); and slip severity (Experiment #3) were compared across outcomes (fail/pass) of the battery tests. Larger fluid pressures, lower coefficient of friction, and more severe slips were observed for shoes that failed the battery tests compared with those passing the tests. This method offers promise for assessing loss in friction and an increase in slip risk for slip-resistant shoes.
Subject(s)
Accidents, Occupational/prevention & control , Ergonomics/instrumentation , Materials Testing/instrumentation , Occupational Injuries/prevention & control , Shoes/adverse effects , Adult , Cross-Sectional Studies , Female , Floors and Floorcoverings , Friction , Humans , Longitudinal Studies , Male , Occupational Injuries/etiology , Surface Properties , Traction/adverse effectsABSTRACT
Traction testing of footwear is expensive, which may create barriers for certain users to assess footwear. This study aimed to develop a statistical model that predicts available coefficient of friction (ACOF) under boundary lubrication conditions based on inexpensive measurements of footwear outsole features. Geometric and material hardness parameters were measured from fifty-eight footwear designs labeled as slip-resistant. A robotic friction measurement device was used to quantify ACOF with canola oil as the contaminant. Stepwise regression methods were used to develop models based on the outsole parameters and floor type to predict ACOF. The predictive ability of the regression models was tested using the k-fold cross-validation method. Results indicated that 87% of ACOF variation was explained by three shoe outsole parameters (tread surface area, heel shape, hardness) and floor type. This approach may provide an assessment tool for safety practitioners to assess footwear traction and improve workers' safety.
Subject(s)
Floors and Floorcoverings , Shoes , Accidental Falls/prevention & control , Equipment Design , Female , Friction , Humans , Male , Surface PropertiesABSTRACT
Available coefficient of friction (ACOF) is a common metric of footwear traction performance. ACOF is the ratio of friction to normal force, often averaged over a time-interval. The time-interval needed to achieve repeatable and valid ACOF is unknown. A post-hoc analysis was performed on nine shoe-floor-contaminant combinations to assess the repeatability and bias of data averaged across 4 time-intervals (2â¯ms, 50â¯ms, 100â¯ms, 200â¯ms) after the target normal force was reached. The ability to predict human slips was assessed for ACOF across these intervals. Differences in repeatability and validity across the four intervals were small. However, statistically significant differences were observed for the shortest compared with the longest interval (lower repeatability yet modestly improved predictive ability). Given the limited impact of time-interval on the results, a shorter interval of 50â¯ms is recommended to enable testing of smaller floor samples.
Subject(s)
Floors and Floorcoverings , Shoes , Accidental Falls , Biomechanical Phenomena , Friction , Humans , Reproducibility of Results , Surface Properties , Time FactorsABSTRACT
Shoe wear is known to increase slipping risk, but few studies have systematically studied this relationship. This study investigated the impact of progressive shoe wear on the available coefficient of friction (ACOF) and under-shoe fluid dynamics. Five different slip-resistant shoes were progressively worn using an accelerated, abrasive, wear protocol. The ACOF and fluid forces (the load supported by the fluid) were measured as shoes were slipped across a surface contaminated with a diluted glycerol solution. As the shoes became worn, an initial increase in ACOF was followed by a steady decrease. Low fluid forces were observed prior to wear followed by increased fluid forces as the worn region became larger. Results suggest that traction performance decreases particularly when the heel region without tread exceeds a size of 800â¯mm2. This study supports the concept of developing shoe replacement guidelines based upon the size of the worn region to reduce occupational slips.
Subject(s)
Accidental Falls/prevention & control , Accidents, Occupational/prevention & control , Shoes/adverse effects , Traction/adverse effects , Floors and Floorcoverings , Friction , Humans , Surface PropertiesABSTRACT
Assessing footwear slip-resistance is critical to preventing slip and fall accidents. The STM 603 (SATRA Technology) is commonly used to assess footwear friction but its ability to predict human slips while walking is unclear. This study assessed this apparatus' ability to predict slips across footwear designs and to determine if modifying the test parameters alters predictions. The available coefficient of friction (ACOF) was measured with the device for nine different footwear designs using 12 testing conditions with varying vertical force, speed and shoe angle. The occurrence of slipping and the required coefficient of friction was quantified from human gait data including 124 exposures to liquid contaminants. ACOF values varied across the test conditions leading to different slip prediction models. Generally, a steeper shoe angle (13°) and higher vertical forces (400 or 500 N) modestly improved predictions of slipping. This study can potentially guide improvements in predictive test conditions for this device. Practitioner Summary: Frictional measures by the STM603 (SATRA Technology) were able to predict human slips under liquid contaminant conditions. Test parameters did have an influence on the measurements. An increased shoe-floor testing angle resulted in better slip predictions than test methods specified in the ASTM F2913 standard.
Subject(s)
Accidental Falls/prevention & control , Equipment Design , Friction , Shoes , Walking , Adolescent , Adult , Biomechanical Phenomena , Female , Floors and Floorcoverings , Humans , Logistic Models , Male , Walking/physiology , Young AdultABSTRACT
Measuring the available coefficient of friction (ACOF) of a shoe-floor interface is influenced by the choice of normal force, shoe-floor angle and sliding speed. The purpose of this study was to quantify the quality of slip prediction models based on ACOF values measured across different testing conditions. A dynamic ACOF measurement device that tests entire footwear specimens (Portable Slip Simulator) was used. The ACOF was measured for nine different footwear-contaminant combinations with two levels of normal force, sliding speed and shoe-floor angle. These footwear-contaminant combinations were also used in human gait studies to quantify the required coefficient of friction (RCOF) and slip outcomes. The results showed that test conditions significantly influenced ACOF. The condition that best predicted slip risk during the gait studies was 250â¯N normal force, 17° shoe-floor angle, 0.5â¯m/s sliding speed. These findings can inform footwear slip-resistance measurement methods to improve design and prevent slips.
Subject(s)
Floors and Floorcoverings , Friction , Shoes , Accidental Falls , Adolescent , Adult , Equipment Design , Female , Gait , Glycerol , Humans , Logistic Models , Male , Models, Theoretical , Rapeseed Oil , Surface Properties , Water , Young AdultABSTRACT
This paper quantified the heel kinematics and kinetics during human slips with the goal of guiding available coefficient of friction (ACOF) testing methods for footwear and flooring. These values were then compared to the testing parameters recommended for measuring shoe-floor ACOF. Kinematic and kinetic data of thirty-nine subjects who experienced a slip incident were pooled from four similar human slipping studies for this secondary analysis. Vertical ground reaction force (VGRF), center of pressure (COP), shoe-floor angle, side-slip angle, sliding speed and contact time were quantified at slip start (SS) and at the time of peak sliding speed (PSS). Statistical comparisons were used to test if any discrepancies exist between the state of slipping foot and current ACOF testing parameters. The main findings were that the VGRF (26.7 %BW, 179.4â¯N), shoe-floor angle (22.1°) and contact time (0.02â¯s) at SS were significantly different from the recommended ACOF testing parameters. Instead, the testing parameters are mostly consistent with the state of the shoe at PSS. We argue that changing the footwear testing parameters to conditions at SS is more appropriate for relating ACOF to conditions of actual slips, including lower vertical forces, larger shoe-floor angles and shorter contact duration.
Subject(s)
Accidental Falls , Mechanical Phenomena , Movement , Shoes , Adult , Biomechanical Phenomena , Floors and Floorcoverings , Friction , Humans , Kinetics , Male , PressureABSTRACT
The variability in friction and slip propensity across slip resistant (SR) shoes is poorly understood. This study aimed to quantify the impact of shoe design features on the available coefficient of friction (ACOF) across shoes labeled as SR. Differences in ACOF and the slipping rate across SR shoes were also quantified. Twelve shoes were tested across five types of flooring and three contaminant conditions using a whole shoe mechanical slip tester. Geometric and hardness parameters were measured to determine the effect of heel outsole design on ACOF. The rate of slipping was evaluated for three of the shoes on vinyl tile with canola oil using human subjects. Differences in ACOF were significant across shoe outsole designs (pâ¯<â¯.001). ACOF was correlated with geometrical and hardness parameters. Rate of slipping was lower for the highest ACOF shoe (pâ¯<â¯.001). This information can be used to guide SR shoe selection and design.