Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Hamostaseologie ; 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38428837

ABSTRACT

BACKGROUND: We report the case of a 59-year-old multiple myeloma patient in whom an anti-human thrombin IgA antibody led to prolonged in vitro coagulation times, suggesting inhibitors to all intrinsic coagulation factors in the absence of spontaneous bleeding. METHODS: Routine and extensive special coagulation tests, in vivo bleeding time, and specific antibody testing were performed. RESULTS: Although the patient did not suffer from spontaneous bleeding and had a normal in vivo bleeding time, the anti-human thrombin IgA autoantibody affected all coagulation assays involving human thrombin in vitro, mimicking inhibitors to intrinsic coagulation factors. As the IgA paraprotein and the IgA antibody virtually disappeared after autologous stem cell transplantation, the coagulation tests also largely normalized. CONCLUSION: Antibodies to human thrombin may interfere with all coagulation assays involving thrombin, imitating a severe coagulopathy. However, in vivo they do not necessarily lead to strongly increased bleeding tendency. Complex and ambiguous coagulation abnormalities should be evaluated and treated in an interdisciplinary setting, including a highly specialized coagulation laboratory, from the beginning.

2.
Int J Lab Hematol ; 45(5): 758-765, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37194625

ABSTRACT

INTRODUCTION: The objective of the present study was to evaluate and compare the validity and utility of two fully automated ADAMTS13 (a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13) activity assays for clinical diagnostic decision-making and to compare their performance. METHODS: Two automated ADAMTS13 activity assays (Werfen HemosIL® AcuStar ADAMTS13 Activity, Technoclone Technofluor ADAMTS13 Activity) were compared with a manual FRET assay (BioMedica ACTIFLUOR ADAMTS13 Activity). The following samples were used: 13 acute phase TTP (thrombotic thrombocytopenic purpura) samples from 11 different patients, one sample from a patient with congenital ADAMTS13 deficiency, 16 samples from control patients, three follow-up samples from TTP patients in long-term remission and one sample from a patient with stem cell transplantation related thrombotic microangiopathy (TMA). The WHO 1st International Standard for ADAMTS13 and several dilutions of normal plasma with ADAMTS13-depleted normal plasma were also tested. Statistical analysis included descriptive statistics, sensitivity and specificity, Passing & Bablok regression and Bland-Altman plot. RESULTS: The quantitative comparison between the HemosIL® (x) and Technofluor (y) methods showed a strong correlation (Pearson r = 0.98, n = 49). When considering an ADAMTS13 activity of <10% as a hallmark for the diagnosis of TTP, two fully automated assays were both able to identify all TTP- and non-TTP-samples correctly, resulting in sensitivities and specificities of 100%. CONCLUSION: Both fully automated ADAMTS13 activity assays showed a good diagnostic performance and quantitative correlation among themselves, discriminating reliably between TTP- and non-TTP-patients.


Subject(s)
Hematopoietic Stem Cell Transplantation , Purpura, Thrombotic Thrombocytopenic , Thrombotic Microangiopathies , Humans , ADAM Proteins/metabolism , ADAMTS13 Protein , Fluorescence Resonance Energy Transfer , Purpura, Thrombotic Thrombocytopenic/diagnosis
3.
Microbiol Spectr ; 10(6): e0059722, 2022 12 21.
Article in English | MEDLINE | ID: mdl-36222681

ABSTRACT

Determination of antibody levels against the nucleocapsid (N) and spike (S) proteins of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are used to estimate the humoral immune response after SARS-CoV-2 infection or vaccination. Differences in the design and specification of antibody assays challenge the interpretation of test results, and comparative studies are often limited to single time points per patient. We determined the longitudinal kinetics of antibody levels of 145 unvaccinated coronavirus disease 2019 (COVID-19) patients at four visits over 1 year upon convalescence using 8 commercial SARS-CoV-2 antibody assays (from Abbott, DiaSorin, Roche, Siemens, and Technoclone), as well as a virus neutralization test (VNT). A linear regression model was used to investigate whether antibody results obtained in the first 6 months after disease onset could predict the VNT results at 12 months. Spike protein-specific antibody tests showed good correlation to the VNT at individual time points (rS, 0.74 to 0.92). While longitudinal assay comparison with the Roche Elecsys anti-SARS-CoV-2 S test showed almost constant antibody concentrations over 12 months, the VNT and all other tests indicated a decline in serum antibody levels (median decrease to 14% to 36% of baseline). The antibody level at 3 months was the best predictor of the VNT results at 12 months after disease onset. The current standardization to a WHO calibrator for normalization to binding antibody units (BAU) is not sufficient for the harmonization of SARS-CoV-2 antibody tests. Assay-specific differences in absolute values and trends over time need to be considered when interpreting the course of antibody levels in patients. IMPORTANCE Determination of antibodies against SARS-CoV-2 will play an important role in detecting a sufficient immune response. Although all the manufacturers expressed antibody levels in binding antibody units per milliliter, thus suggesting comparable results, we found discrepant behavior between the eight investigated assays when we followed the antibody levels in a cohort of 145 convalescent patients over 1 year. While one assay yielded constant antibody levels, the others showed decreasing antibody levels to a varying extent. Therefore, the comparability of the assays must be improved regarding the long-term kinetics of antibody levels. This is a prerequisite for establishing reliable antibody level cutoffs for sufficient individual protection against SARS-CoV-2.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , Follow-Up Studies , Antibodies, Viral , Immunity, Humoral , Antibodies, Neutralizing
4.
Ther Adv Hematol ; 13: 20406207221104595, 2022.
Article in English | MEDLINE | ID: mdl-35923771

ABSTRACT

The introduction of extended factor IX (FIX) products has significantly facilitated the treatment of hemophilia B patients. However, optimal perioperative management remains a topic of hot debate, particularly in surgeries with high bleeding risk. For the first time, we report here a patient with mild hemophilia B and degenerative aneurysms of aortic root and ascending aorta undergoing elective Bentall's operation with full cardiopulmonary bypass, who was successfully managed with eftrenonacog alfa (Alprolix®), a recombinant FIX Fc fusion protein (rFIXFc). rFIXFc could safely be monitored using the Pathromtin SL aPTT-reagent. No significant bleeding was noted intraoperatively despite systemic heparinization as well as postoperatively. Higher doses of rFIXFc were inevitable to reach target FIX levels intraoperatively, whereas in the post-surgery setting stable FIX concentrations were maintained with only few rFIXFc injections facilitating fast wound healing and remobilization of the patient.

5.
J Clin Virol Plus ; 2(1): 100058, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35262031

ABSTRACT

The presence of neutralizing antibodies against SARS-CoV-2 in a large number of people is - besides cellular immunity - important to overcome the SARS-CoV-2 pandemic. While determination of neutralizing antibodies via virus neutralization tests are laborious, assays to determine the antibody levels serologically are fully automated and widely available. Correlations between these methodologies were recently given by the manufacturers, however performance in samples close to the cut off value have not yet been fully validated. Thus, we analysed 22 borderline and low positive (<100 BAU/ml) samples and 9 high positive (≥ 100 BAU/ml) from infected and/or vaccinated individuals and compared the SARS-CoV-2 IgG II Quant assay (Abbott), LIAISON SARS-CoV-2 TrimericS IgG (Diasorin), Elecsys Anti-SARS-CoV-2 S (Roche), and SARS-CoV-2 IgG (Siemens) with results obtained from a virus neutralization test. Based on the cut off values given by Abbott, Diasorin, Roche, and Siemens, the positive serologic results were concordant with the virus neutralization test in 100%, 76%, 88%, and 71%, respectively, while in turn, negative ones were in agreement in 29%, 79%, 93%, and 86%, respectively. In conclusion, weakly positive, serologic results are challenging to correctly predict the presence of neutralizing antibodies. Our study suggests, that different cut off values (for positivity vs. presence of neutralizing antibodies) could improve the test's performance, but determination thereof requires more samples to be analysed.

6.
Transplantation ; 106(4): 792-805, 2022 04 01.
Article in English | MEDLINE | ID: mdl-34144552

ABSTRACT

BACKGROUND: Normothermic machine perfusion (NMP) has become a clinically established tool to preserve livers in a near-physiological environment. However, little is known about the predictive value of perfusate parameters toward the outcomes after transplantation. METHODS: Fifty-five consecutive NMP livers between 2018 and 2019 were included. All of the livers were perfused on the OrganOx metra device according to an institutional protocol. Transplant and perfusion data were collected prospectively. RESULTS: Forty-five livers were transplanted after NMP. Five livers stem from donors after circulatory death and 31 (68.9%) from extended criteria donors. Mean (SD) cold ischemia time was 6.4 (2.3) h; mean (SD) total preservation time was 21.4 (7.1) h. Early allograft dysfunction (EAD) occurred in 13 of 45 (28.9%) patients. Perfusate aspartate aminotransferase (P = 0.008), alanine aminotransferase (P = 0.006), lactate dehydrogenase (P = 0.007) and their development over time, alkaline phosphatase (P = 0.013), and sodium (P = 0.016) correlated with EAD. Number of perfusate platelets correlated with cold ischemia time duration and were indicative for the occurrence of EAD. Moreover, von Willebrand Factor antigen was significantly higher in perfusates of EAD livers (P < 0.001), and Δ von Willebrand factor antigen correlated with EAD. Although perfusate lactate and glucose had no predictive value, EAD was more likely to occur in livers with lower perfusate pH (P = 0.008). ΔPerfusate alkaline phosphatase, Δperfusate aspartate aminotransferase, Δperfusate alanine aminotransferase, and Δperfusate lactate dehydrogenase correlated closely with model for early allograft function but not liver graft assessment following transplantation risk score. Bile parameters correlated with extended criteria donor and donor risk index. CONCLUSIONS: Biomarker assessment during NMP may help to predict EAD after liver transplantation. The increase of transaminases and lactate dehydrogenase over time as well as platelets and vWF antigen are important factors indicative for EAD.


Subject(s)
Allografts/immunology , Blood Platelets , Enzymes , Liver Transplantation , Liver , Organ Preservation , Perfusion , Biomarkers , Humans , Organ Preservation/methods , Perfusion/adverse effects
7.
EBioMedicine ; 67: 103348, 2021 May.
Article in English | MEDLINE | ID: mdl-33906067

ABSTRACT

BACKGROUND: Antibody tests are essential tools to investigate humoral immunity following SARS-CoV-2 infection or vaccination. While first-generation antibody tests have primarily provided qualitative results, accurate seroprevalence studies and tracking of antibody levels over time require highly specific, sensitive and quantitative test setups. METHODS: We have developed two quantitative, easy-to-implement SARS-CoV-2 antibody tests, based on the spike receptor binding domain and the nucleocapsid protein. Comprehensive evaluation of antigens from several biotechnological platforms enabled the identification of superior antigen designs for reliable serodiagnostic. Cut-off modelling based on unprecedented large and heterogeneous multicentric validation cohorts allowed us to define optimal thresholds for the tests' broad applications in different aspects of clinical use, such as seroprevalence studies and convalescent plasma donor qualification. FINDINGS: Both developed serotests individually performed similarly-well as fully-automated CE-marked test systems. Our described sensitivity-improved orthogonal test approach assures highest specificity (99.8%); thereby enabling robust serodiagnosis in low-prevalence settings with simple test formats. The inclusion of a calibrator permits accurate quantitative monitoring of antibody concentrations in samples collected at different time points during the acute and convalescent phase of COVID-19 and disclosed antibody level thresholds that correlate well with robust neutralization of authentic SARS-CoV-2 virus. INTERPRETATION: We demonstrate that antigen source and purity strongly impact serotest performance. Comprehensive biotechnology-assisted selection of antigens and in-depth characterisation of the assays allowed us to overcome limitations of simple ELISA-based antibody test formats based on chromometric reporters, to yield comparable assay performance as fully-automated platforms. FUNDING: WWTF, Project No. COV20-016; BOKU, LBI/LBG.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Coronavirus Nucleocapsid Proteins/immunology , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/chemistry , Spike Glycoprotein, Coronavirus/immunology , Adolescent , Adult , Aged , Aged, 80 and over , Animals , Binding Sites , CHO Cells , COVID-19/immunology , Cricetulus , Early Diagnosis , HEK293 Cells , Humans , Immunoglobulin G/blood , Middle Aged , Sensitivity and Specificity , Young Adult
8.
Clin Chem Lab Med ; 59(8): 1453-1462, 2021 07 27.
Article in English | MEDLINE | ID: mdl-33837679

ABSTRACT

OBJECTIVES: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections cause coronavirus disease 2019 (COVID-19) and induce a specific antibody response. Serological assays detecting IgG against the receptor binding domain (RBD) of the spike (S) protein are useful to monitor the immune response after infection or vaccination. The objective of our study was to evaluate the clinical performance of the Siemens SARS-CoV-2 IgG (sCOVG) assay. METHODS: Sensitivity and specificity of the Siemens sCOVG test were evaluated on 178 patients with SARS-CoV-2-infection and 160 pre-pandemic samples in comparison with its predecessor test COV2G. Furthermore, correlation with virus neutralization titers was investigated on 134 samples of convalescent COVID-19 patients. RESULTS: Specificity of the sCOVG test was 99.4% and sensitivity was 90.5% (COV2G assay 78.7%; p<0.0001). S1-RBD antibody levels showed a good correlation with virus neutralization titers (r=0.843; p<0.0001) and an overall qualitative agreement of 98.5%. Finally, median S1-RBD IgG levels increase with age and were significantly higher in hospitalized COVID-19 patients (median levels general ward: 25.7 U/mL; intensive care: 59.5 U/mL) than in outpatients (3.8 U/mL; p<0.0001). CONCLUSIONS: Performance characteristics of the sCOVG assay have been improved compared to the predecessor test COV2G. Quantitative SARS-CoV-2 S1-RBD IgG levels could be used as a surrogate for virus neutralization capacity. Further harmonization of antibody quantification might assist to monitor the humoral immune response after COVID-19 disease or vaccination.


Subject(s)
Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , COVID-19/diagnosis , Immunoglobulin G/immunology , Neutralization Tests , SARS-CoV-2/metabolism , Spike Glycoprotein, Coronavirus/immunology , Adult , Aged , Aged, 80 and over , Antibodies, Neutralizing/blood , Antibodies, Viral/blood , COVID-19/pathology , COVID-19/virology , Female , Humans , Immunoglobulin G/blood , Male , Middle Aged , Protein Subunits/immunology , Reagent Kits, Diagnostic , SARS-CoV-2/isolation & purification , Sensitivity and Specificity , Severity of Illness Index , Young Adult
9.
Clin Chem Lab Med ; 59(6): 1143-1154, 2021 05 26.
Article in English | MEDLINE | ID: mdl-33554557

ABSTRACT

OBJECTIVES: Serological tests detect antibodies against Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in the ongoing coronavirus disease-19 (COVID-19) pandemic. Independent external clinical validation of performance characteristics is of paramount importance. METHODS: Four fully automated assays, Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, Siemens SARS-CoV-2 total (COV2T) and SARS-CoV-2 IgG (COV2G) were evaluated using 350 pre-pandemic samples and 700 samples from 245 COVID-19 patients (158 hospitalized, 87 outpatients). RESULTS: All tests showed very high diagnostic specificity. Sensitivities in samples collected at least 14 days after disease onset were slightly lower than manufacturers' claims for Roche (93.0%), Abbott (90.8%), and Siemens COV2T (90.3%), and distinctly lower for Siemens COV2G (78.8%). Concordantly negative results were enriched for immunocompromised patients. ROC curve analyses suggest a lowering of the cut-off index for the Siemens COV2G assay. Finally, the combination of two anti-SARS-CoV-2 antibody assays is feasible when considering borderline reactive results. CONCLUSIONS: Thorough on-site evaluation of commercially available serologic tests for detection of antibodies against SARS-CoV-2 remains imperative for laboratories. The potentially impaired sensitivity of the Siemens COV2G necessitates a switch to the company's newly filed SARS-CoV-2 IgG assay for follow-up studies. A combination of tests could be considered in clinical practice.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoglobulin G/blood , Adult , Aged , Aged, 80 and over , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/epidemiology , Female , Humans , Immunoglobulin G/immunology , Male , Middle Aged , Pandemics , ROC Curve , SARS-CoV-2/immunology , Sensitivity and Specificity , Young Adult
10.
J Clin Med ; 9(4)2020 Mar 31.
Article in English | MEDLINE | ID: mdl-32244368

ABSTRACT

The current study aims to evaluate whether prophylactic anticoagulation using argatroban or an increased dose of unfractionated heparin (UFH) is effective in achieving the targeted activated partial thromboplastin time (aPTT) of more than 45 s in critically ill heparin-resistant (HR) patients. Patients were randomized either to continue receiving an increased dose of UFH, or to be treated with argatroban. The endpoints were defined as achieving an aPTT target of more than 45 s at 7 h and 24 h. This clinical trial was registered on clinicaltrials.gov (NCT01734252) and on EudraCT (2012-000487-23). A total of 42 patients, 20 patients in the heparin and 22 in the argatroban group, were included. Of the patients with continued heparin treatment 55% achieved the target aPTT at 7 h, while only 40% of this group maintained the target aPTT after 24 h. Of the argatroban group 59% reached the target aPTT at 7 h, while at 24 h 86% of these patients maintained the targeted aPTT. Treatment success at 7 h did not differ between the groups (p = 0.1000), whereas at 24 h argatroban showed significantly greater efficacy (p = 0.0021) than did heparin. Argatroban also worked better in maintaining adequate anticoagulation in the further course of the study. There was no significant difference in the occurrence of bleeding or thromboembolic complications between the treatment groups. In the case of heparin-resistant critically ill patients, argatroban showed greater efficacy than did an increased dose of heparin in achieving adequate anticoagulation at 24 h and in maintaining the targeted aPTT goal throughout the treatment phase.

11.
J Cell Mol Med ; 19(10): 2375-84, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26218644

ABSTRACT

Why and when the immune system skews to Th2 mediated allergic immune responses is still poorly characterized. With two homologous lipocalins, the major respiratory dog allergen Can f 1 and the human endogenous, non-allergenic Lipocalin-1, we investigated their impact on human monocyte-derived dendritic cells (DC). The two lipocalins had differential effects on DC according to their allergenic potential. Compared to Lipocalin-1, Can f 1 persistently induced lower levels of the Th1 skewing maturation marker expression, tryptophan breakdown and interleukin (IL)-12 production in DC. As a consequence, T cells stimulated by DC treated with Can f 1 produced more of the Th2 signature cytokine IL-13 and lower levels of the Th1 signature cytokine interferon-γ than T cells stimulated by Lipocalin-1 treated DC. These data were partially verified by a second pair of homologous lipocalins, the cat allergen Fel d 4 and its putative human homologue major urinary protein. Our data indicate that the crosstalk of DC with lipocalins alone has the potential to direct the type of immune response to these particular antigens. A global gene expression analysis further supported these results and indicated significant differences in intracellular trafficking, sorting and antigen presentation pathways when comparing Can f 1 and Lipocalin-1 stimulated DC. With this study we contribute to a better understanding of the induction phase of a Th2 immune response.


Subject(s)
Allergens/immunology , Dendritic Cells/immunology , Immunity , Lipocalin 1/metabolism , Sequence Homology, Amino Acid , Allergens/chemistry , Animals , Antigen Presentation/genetics , Antigen Presentation/immunology , Biomarkers/metabolism , CD4-Positive T-Lymphocytes/immunology , Cell Differentiation , Dendritic Cells/cytology , Dogs , Gene Expression Regulation , Glycoproteins/immunology , Humans , Interferon-gamma/biosynthesis , Interleukin-12/biosynthesis , Interleukin-13/biosynthesis , Lipocalins , Monocytes/cytology , Tryptophan/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...