ACS Biomater Sci Eng ; 8(3): 939-963, 2022 03 14.
Article in English | MEDLINE | ID: mdl-35171560

ABSTRACT

The developers of medical devices evaluate the biocompatibility of their device prior to FDA's review and subsequent introduction to the market. Chemical characterization, described in ISO 10993-18:2020, can generate information for toxicological risk assessment and is an alternative approach for addressing some biocompatibility end points (e.g., systemic toxicity, genotoxicity, carcinogenicity, reproductive/developmental toxicity) that can reduce the time and cost of testing and the need for animal testing. Additionally, chemical characterization can be used to determine whether modifications to the materials and manufacturing processes alter the chemistry of a patient-contacting device to an extent that could impact device safety. Extractables testing is one approach to chemical characterization that employs combinations of non-targeted analysis, non-targeted screening, and/or targeted analysis to establish the identities and quantities of the various chemical constituents that can be released from a device. Due to the difficulty in obtaining a priori information on all the constituents in finished devices, information generation strategies in the form of analytical chemistry testing are often used. Identified and quantified extractables are then assessed using toxicological risk assessment approaches to determine if reported quantities are sufficiently low to overcome the need for further chemical analysis, biological evaluation of select end points, or risk control. For extractables studies to be useful as a screening tool, comprehensive and reliable non-targeted methods are needed. Although non-targeted methods have been adopted by many laboratories, they are laboratory-specific and require expensive analytical instruments and advanced technical expertise to perform. In this Perspective, we describe the elements of extractables studies and provide an overview of the current practices, identified gaps, and emerging practices that may be adopted on a wider scale in the future. This Perspective is outlined according to the steps of an extractables study: information gathering, extraction, extract sample processing, system selection, qualification, quantification, and identification.


Subject(s)
Drug Contamination , Risk Assessment , Animals , Drug Contamination/prevention & control , Humans
2.
Ann Biomed Eng ; 46(1): 14-24, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28948381

ABSTRACT

A novel approach for rapid risk assessment of targeted leachables in medical device polymers is proposed and validated. Risk evaluation involves understanding the potential of these additives to migrate out of the polymer, and comparing their exposure to a toxicological threshold value. In this study, we propose that a simple diffusive transport model can be used to provide conservative exposure estimates for phase separated color additives in device polymers. This model has been illustrated using a representative phthalocyanine color additive (manganese phthalocyanine, MnPC) and polymer (PEBAX 2533) system. Sorption experiments of MnPC into PEBAX were conducted in order to experimentally determine the diffusion coefficient, D = (1.6 ± 0.5) × 10-11 cm2/s, and matrix solubility limit, C s = 0.089 wt.%, and model predicted exposure values were validated by extraction experiments. Exposure values for the color additive were compared to a toxicological threshold for a sample risk assessment. Results from this study indicate that a diffusion model-based approach to predict exposure has considerable potential for use as a rapid, screening-level tool to assess the risk of color additives and other small molecule additives in medical device polymers.


Subject(s)
Coloring Agents/chemistry , Models, Theoretical , Polymers/chemistry , Consumer Product Safety , Diffusion , Equipment and Supplies , Indoles/chemistry , Isoindoles , Risk Assessment
3.
J Neural Eng ; 12(2): 026003, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25627426

ABSTRACT

OBJECTIVE: A challenge for implementing high bandwidth cortical brain-machine interface devices in patients is the limited functional lifespan of implanted recording electrodes. Development of implant technology currently requires extensive non-clinical testing to demonstrate device performance. However, testing the durability of the implants in vivo is time-consuming and expensive. Validated in vitro methodologies may reduce the need for extensive testing in animal models. APPROACH: Here we describe an in vitro platform for rapid evaluation of implant stability. We designed a reactive accelerated aging (RAA) protocol that employs elevated temperature and reactive oxygen species (ROS) to create a harsh aging environment. Commercially available microelectrode arrays (MEAs) were placed in a solution of hydrogen peroxide at 87 °C for a period of 7 days. We monitored changes to the implants with scanning electron microscopy and broad spectrum electrochemical impedance spectroscopy (1 Hz-1 MHz) and correlated the physical changes with impedance data to identify markers associated with implant failure. MAIN RESULTS: RAA produced a diverse range of effects on the structural integrity and electrochemical properties of electrodes. Temperature and ROS appeared to have different effects on structural elements, with increased temperature causing insulation loss from the electrode microwires, and ROS concentration correlating with tungsten metal dissolution. All array types experienced impedance declines, consistent with published literature showing chronic (>30 days) declines in array impedance in vivo. Impedance change was greatest at frequencies <10 Hz, and smallest at frequencies 1 kHz and above. Though electrode performance is traditionally characterized by impedance at 1 kHz, our results indicate that an impedance change at 1 kHz is not a reliable predictive marker of implant degradation or failure. SIGNIFICANCE: ROS, which are known to be present in vivo, can create structural damage and change electrical properties of MEAs. Broad-spectrum electrical impedance spectroscopy demonstrates increased sensitivity to electrode damage compared with single-frequency measurements. RAA can be a useful tool to simulate worst-case in vivo damage resulting from chronic electrode implantation, simplifying the device development lifecycle.


Subject(s)
Brain/physiology , Coated Materials, Biocompatible/chemistry , Electrodes, Implanted , Reactive Oxygen Species/chemistry , Resins, Synthetic/chemistry , Tungsten/chemistry , Equipment Design , Equipment Failure Analysis/methods , Humans , Materials Testing/methods , Microelectrodes , Time Factors
4.
J Biomed Mater Res B Appl Biomater ; 101(6): 1006-13, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23559362

ABSTRACT

The Intergel® ferric crosslinked hyaluronate (FeHA) adhesion prevention solution (APS) (FDA) is associated with serious post-operative complications (Henley, http://www.lawyersandsettlements.com/features/gynecare-intergel/intergel-timeline.html, 2007; FDA, 2003; Roman et al., Fertil Steril 2005, 83 Suppl 1:1113-1118; Tang et al., Ann Surg 2006;243(4):449-455; Wiseman, Fertil Steril 2006;86(3):771; Wiseman, Fertil Steril 2006;85(4):e7). This prompted us to examine the in situ stability of crosslinked HA materials to hyaluronidase lyase degradation. Variables such as ferric ionic crosslink density, HA concentration, gel geometry, and molecular weight (MW) of HA polymer were studied. Various formulations of the crosslinked "in house" [Isayeva et al., J Biomed Mater Res: Part B - Appl Biomater 2010, 95B (1):9-18] FeHA (0.5%, w/v; 30, 50, 90% crosslinked), the Intergel® FeHA (0.5%, w/v; 90%), and the non-crosslinked HA (0.05-0.5%, w/v) were degraded at a fixed activity of hyaluronidase lyase from Streptomyces hyalurolyticus (Hyase) at 37°C over time according to the method [Payan et al., J Chrom B: Biomed Sci Appl 1991;566(1):9-18]. Under our conditions, the data show that the crosslink density affects degradation the most, followed by HA concentration and then gel geometry. We found that MW has no effect. Our results are one possible explanation of the observations that the Intergel® FeHA APS (0.5%, w/v; 90%) material persisted an order of magnitude longer than expected [t1/2 = 500 hrs vs. t1/2 = 50 hrs (FDA; Johns et al., Fertil Steril 1997;68(1):37-42)]. These data also demonstrate the sensitivity of the in vitro hyaluronidase assay to predict the in situ stability of crosslinked HA medical products as previously reported [Sall et al., Polym Degrad Stabil 2007;92(5):915-919].


Subject(s)
Ferric Compounds/chemistry , Ferric Compounds/pharmacology , Hyaluronic Acid/chemistry , Hyaluronic Acid/pharmacology , Tissue Adhesions/prevention & control , Biocompatible Materials/adverse effects , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Cross-Linking Reagents , Drug Stability , Ferric Compounds/adverse effects , Gels , Humans , Hyaluronic Acid/adverse effects , Hyaluronoglucosaminidase , Materials Testing , Molecular Weight , Solutions
5.
Med Devices (Auckl) ; 4: 1-10, 2011.
Article in English | MEDLINE | ID: mdl-22915924

ABSTRACT

Hyaluronic acid (HA), in linear or cross-linked form, is a common component of cosmetics, personal care products, combination medical products, and medical devices. In all cases, the ability of the HA solution or gel to wet surfaces and/or disrupt and lubricate interfaces is a limiting feature of its mechanism of action. We synthesized ferric ion-cross-linked networks of HA based on an adhesion barrier, varied the degree of cross-linking, and performed wetting goniometry, viscometry, and dynamic mechanical analysis. As cross-linking increases, so do contact angle, viscosity, storage modulus, and loss modulus; thus, wetting and lubrication are compromised. These findings have implications in medical device materials, such as adhesion barriers and mucosal drug delivery vehicles.