Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Shokuhin Eiseigaku Zasshi ; 63(2): 51-61, 2022.
Article in Japanese | MEDLINE | ID: mdl-35650029

ABSTRACT

Migration test of food utensils, containers, and packaging is an important test method for confirming the safety and their compliance to the standards. However, there is little report on inter-laboratory study which was performed to evaluate the entire migration test, including migration operations and quantification. An interlaboratory study was performed participating 22 laboratories using 8 types of model synthetic resin samples containing 10 substances with a wide range of Log Pow values to evaluate the accuracy of the entire migration test. As a result, most of HorRat (r) values met the target criteria (0.3

Subject(s)
Food Contamination , Plastics , Food Contamination/analysis , Food Packaging , Laboratories
2.
Shokuhin Eiseigaku Zasshi ; 59(1): 55-63, 2018.
Article in Japanese | MEDLINE | ID: mdl-29743469

ABSTRACT

An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using three food-simulating solvents (water, 4% acetic acid and 20% ethanol), based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. For evaporation, a water bath was used in the official method, and a hot plate in the modified method. In most laboratories, the test solutions were heated until just prior to evaporation to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods, regardless of the heating equipment used. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method.


Subject(s)
Cooking and Eating Utensils , Food Contamination/analysis , Food Packaging , Acetic Acid , Ethanol , Food Contamination/prevention & control , Japan , Laboratories , Solutions , Solvents , Volatilization , Water
3.
Shokuhin Eiseigaku Zasshi ; 59(1): 64-71, 2018.
Article in Japanese | MEDLINE | ID: mdl-29743470

ABSTRACT

An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using heptane as a food-simulating solvent for oily or fatty foods, based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. In the official method, heating for evaporation was done with a water bath. In the modified method, a hot plate was used for evaporation, and/or a vacuum concentration procedure was skipped. In most laboratories, the test solutions were heated until just prior to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method. Furthermore, an interlaboratory study was performed to evaluate and compare two leaching solutions (95% ethanol and isooctane) used as food-simulating solvents for oily or fatty foods in the EU. The results demonstrated that there was no significant difference between heptane and these two leaching solutions.


Subject(s)
Cooking and Eating Utensils , Food Contamination/analysis , Food Packaging , Ethanol , Fatty Alcohols , Food Contamination/prevention & control , Japan , Laboratories , Legislation, Food , Octanes , Solutions , Volatilization
SELECTION OF CITATIONS
SEARCH DETAIL
...