1.
Acta Ortop Bras ; 29(2): 97-100, 2021.
Article in English | MEDLINE | ID: mdl-34248409

ABSTRACT

OBJECTIVE: To evaluate the reproducibility of a S2-alar iliac (S2AI) screw parameters measurement method by inter and intraobserver reliability. METHODS: Cross-sectional study, considering computed tomography exams. Morphometric analysis was performed by multiplanar reconstructions. Screw length, diameter and trajectory angles were the studied variables. To analyze the measurements reproducibility, intraclass correlation coefficient (ICC) was used. RESULTS: Interobserver reliability was classified as strong for screw shortest length (ICC: 0.742) and diameter (ICC: 0.699). Interobserver reliability was classified as moderate for screw longest length (ICC: 0.553) and for screw trajectory angles in the axial plane for the longest (ICC: 0.478) and for the shortest lengths (ICC: 0.591). Intraobserver reliability was interpreted as excellent for screw shortest (ICC: 0.932) and longest lengths (ICC: 0.962) and diameter (ICC: 0.770) and screw trajectory angles in the axial plane for the screw longest (ICC: 0.773) and shortest lengths (ICC: 0.862). There were weak interobserver and strong intraobserver reliabilities for trajectory angle in sagittal plane, but no statistical significance was found. CONCLUSION: Inter and intraobserver reliability of S2AI screw morphometric parameters were interpreted from moderate to excellent in almost all studied variables, except for the screw trajectory angle in the sagittal plane measurement. Level of Evidence IV, Diagnostic Studies - Investigating a Diagnostic Test.


OBJETIVO: Avaliar a reprodutibilidade, por meio da concordância inter e intraobservador, de um método de aferição dos parâmetros sacropélvicos do parafuso S2-asa do ilíaco (S2AI). MÉTODOS: Estudo transversal, considerando exames de tomografia computadorizada. A análise morfométrica foi feita por meio de reconstruções multiplanares. As variáveis estudadas foram: comprimento, diâmetro e ângulos de trajetória do parafuso S2AI. Para análise da reprodutibilidade das medidas, utilizou-se o coeficiente de correlação intraclasse (ICC). RESULTADOS: A confiabilidade interobservador foi classificada como forte para o menor comprimento (ICC: 0,742) e diâmetro (ICC: 0,699). Em relação ao maior comprimento (ICC: 0,553) e aos ângulos de trajetória axial para o maior (ICC: 0,478) e para o menor comprimento (ICC: 0,591), a confiabilidade interobservador foi classificada como moderada. A confiabilidade intraobservador foi excelente para o menor (ICC: 0,932) e maior comprimentos (ICC: 0,962), diâmetro (ICC: 0,770) e ângulos de trajetória axial (ICC: 0,773 - maior comprimento; ICC: 0,862 - menor comprimento). Houve confiabilidade interobservador fraca e intraobservador forte para o ângulo de trajetória sagital, porém sem significância estatística. CONCLUSÃO: A correlação inter e intraobservador dos parâmetros morfométricos do parafuso S2AI mostrou-se de moderada a excelente em quase todas as variáveis estudadas, exceto para o ângulo de trajetória sagital. Nível de Evidência IV, Estudos diagnósticos - Investigação de um exame para diagnóstico.

2.
Rev Bras Ortop (Sao Paulo) ; 55(6): 702-707, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33364647

ABSTRACT

Objective Description of the sacropelvic parameters measurement method for S2-alar iliac (S2AI) screw insertion. Methods Descriptive study of the method for measuring sacropelvic parameters for the insertion of the S2AI screw using computed tomography (CT). The data evaluated in multiplanar reconstructions were the parameters of the screw trajectory, including length, diameter and angles of the trajectory in the axial and sagittal planes. Results From the sagittal reconstruction, the axis of the series of axial slices is angled three-dimensionally so that it is possible to visualize the S2 vertebra, the screw entry point, and the anteroinferior iliac spine (AIIS) in the same plane. The entry point is demarcated at the midpoint between the dorsal foramina of S1 and S2. To measure the length of the screw, lines are drawn tangent to the inner and outer cortices of the iliac. The diameter is determined by the shortest distance between the inner and outer iliac faces minus half of the diameter of the screw chosen medially and laterally. The path angle in the axial plane is formed by the anteroposterior midline of the sacrum and the line of the screw length. The craniocaudal inclination angle in relation to the S1 plateau corresponds to the degree of inclination made in the sagittal plane to find the image in which the entry point and the AIIS are seen in the same plane. Conclusion It was possible to adequately assess, through multiplanar CT reconstructions, the sacropelvic parameters necessary for the safe insertion of the S2AI screw.

3.
Rev. bras. ortop ; 55(6): 702-707, Nov.-Dec. 2020. graf
Article in English | LILACS | ID: biblio-1156200

ABSTRACT

Abstract Objective Description of the sacropelvic parameters measurement method for S2-alar iliac (S2AI) screw insertion. Methods Descriptive study of the method for measuring sacropelvic parameters for the insertion of the S2AI screw using computed tomography (CT). The data evaluated in multiplanar reconstructions were the parameters of the screw trajectory, including length, diameter and angles of the trajectory in the axial and sagittal planes. Results From the sagittal reconstruction, the axis of the series of axial slices is angled three-dimensionally so that it is possible to visualize the S2 vertebra, the screw entry point, and the anteroinferior iliac spine (AIIS) in the same plane. The entry point is demarcated at the midpoint between the dorsal foramina of S1 and S2. To measure the length of the screw, lines are drawn tangent to the inner and outer cortices of the iliac. The diameter is determined by the shortest distance between the inner and outer iliac faces minus half of the diameter of the screw chosen medially and laterally. The path angle in the axial plane is formed by the anteroposterior midline of the sacrum and the line of the screw length. The craniocaudal inclination angle in relation to the S1 plateau corresponds to the degree of inclination made in the sagittal plane to find the image in which the entry point and the AIIS are seen in the same plane. Conclusion It was possible to adequately assess, through multiplanar CT reconstructions, the sacropelvic parameters necessary for the safe insertion of the S2AI screw.


Resumo Objetivo Descrever como aferir os parâmetros sacropélvicos para a inserção segura do parafuso S2-asa do ilíaco (S2AI). Métodos Estudo descritivo do método de aferição dos parâmetros sacropélvicos para a inserção do parafuso S2AI por meio de tomografia computadorizada (TC). Os dados avaliados em reconstruções multiplanares foram os parâmetros da trajetória do parafuso, incluindo comprimento, diâmetro e ângulos de trajetória nos planos axial e sagital. Resultados A partir da reconstrução sagital, angula-se tridimensionalmente o eixo da série de cortes axiais de modo que seja possível visualizar a vértebra S2, o ponto de entrada do parafuso e a espinha ilíaca anteroinferior (EIAI) no mesmo plano. O ponto de entrada é demarcado no ponto médio entre os forames dorsais de S1 e S2. Para medir o comprimento do parafuso, traçam-se linhas tangenciando as corticais interna e externa do ilíaco. O diâmetro é determinado pela menor distância entre as tábuas interna e externa do ilíaco subtraindo metade do diâmetro do parafuso escolhido medialmente e lateralmente. O ângulo de trajetória no plano axial é formado pela linha média anteroposterior do sacro e a linha do comprimento do parafuso. O ângulo de inclinação craniocaudal em relação ao platô de S1 corresponde ao grau de inclinação feito no plano sagital para encontrar a imagem em que o ponto de entrada e a EIAI são vistos no mesmo plano. Conclusão Foi possível aferir adequadamente, por meio de reconstruções multiplanares de TC, os parâmetros sacropélvicos necessários para a inserção segura do parafuso S2AI.