1.
Neuroradiology ; 66(5): 855-863, 2024 May.
Article in English | MEDLINE | ID: mdl-38453715

ABSTRACT

PURPOSE: To assess the feasibility and technical accuracy of performing pedicular screw placement combined with vertebroplasty in the radiological setting. METHODS: Patients who underwent combined vertebroplasty and pedicle screw insertion under combined computed tomography and fluoroscopic guidance in 4 interventional radiology centers from 2018 to 2023 were retrospectively assessed. Patient demographics, vertebral lesion type, and procedural data were analyzed. Strict intra-pedicular screw positioning was considered as technical success. Pain score was assessed according to the Visual Analogue Scale before the procedure and in the 1-month follow-up consultation. RESULTS: Fifty-seven patients (38 men and 19 women) with a mean age of 72.8 (SD = 11.4) years underwent a vertebroplasty associated with pedicular screw insertion for the treatment of traumatic fractures (29 patients) and neoplastic disease (28 patients). Screw placement accuracy assessed by post-procedure CT scan was 95.7% (89/93 inserted screws). A total of 93 pedicle screw placements (36 bi-pedicular and 21 unipedicular) in 32 lumbar, 22 thoracic, and 3 cervical levels were analyzed. Mean reported procedure time was 48.8 (SD = 14.7) min and average injected cement volume was 4.4 (SD = 0.9) mL. A mean VAS score decrease of 5 points was observed at 1-month follow-up (7.7, SD = 1.3 versus 2.7, SD = 1.7), p < .001. CONCLUSION: Combining a vertebroplasty and pedicle screw insertion is technically viable in the radiological setting, with a high screw positioning accuracy of 95.7%.


Subject(s)
Pedicle Screws , Spinal Fractures , Vertebroplasty , Male , Humans , Female , Aged , Retrospective Studies , Feasibility Studies , Spinal Fractures/diagnostic imaging , Spinal Fractures/surgery , Lumbar Vertebrae/surgery , Vertebroplasty/methods
2.
Acta Neurochir (Wien) ; 157(4): 729-37, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25788414

ABSTRACT

BACKGROUND: Improvement of surgical accuracy during DBS-lead implantation has been described recently, leading to "frameless" or "MRI-verified" techniques. However, combining a high-quality definition of the STN using intraoperative 1.5 MRI with the possibility to reduce errors due to co-registration and to monitor lead progression during surgical insertion while checking the absence of surgical complication is an appealing method. We report here surgical methodology, safety, application accuracy, and clinical benefit of STN-lead implantation under MRI guidance. METHODS: Two patients with a severe PD state were treated by bilateral STN-DBS. Leads were implanted under general anesthesia using intraoperative MRI guidance (ClearPoint system). Lead implantation accuracy was measured on T1 axial images at the level of the target. Clinical improvement was measured on the pre- and post-UPDRS 3 scale at 1-year follow-up. RESULTS: Surgery was safe and uneventful in both cases. Radial error was 0.36 (right) and 0.86 mm (left) in case 1, and 0.41 (right) and 0.14 mm (left) in case 2. No edema or hemorrhage were noticed. CONCLUSIONS: Intraoperative MRI guidance allows DBS lead implantation with high accuracy and with great clinical efficacy. A larger cohort of patients is needed to confirm these initial results.


Subject(s)
Deep Brain Stimulation/methods , Magnetic Resonance Imaging/methods , Neuronavigation/methods , Subthalamic Nucleus/physiology , Aged , Female , Humans , Male , Parkinson Disease/surgery , Parkinson Disease/therapy , Subthalamic Nucleus/surgery , Treatment Outcome